19 resultados para therapeutic monitoring

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the optimal technology policy to solve a free-riding problem between the members of a RJV. We assume that when intervening the Government suffers an additional adverse selection problem because it is not able to distinguish the value of the potential innovation. Although subsidies and monitoring may be equivalent policy tools to solve firms' free-riding problem, they imply different social losses if the Government is not able to perfectly distinguish the value of the potential innovation. The supremacy of monitoring tools over subsidies is proved to depend on which type of information the Government is able to obtain about firms' R&D performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze a model where firms chose a production technology which, together with some random event, determines the final emission level. We consider the coexistence of two alternative technologies: a "clean" technology, and a "dirty" technology. The environmental regulation is based on taxes over reported emissions, and on penalties over unreported emissions. We show that the optimal inspection policy is a cut-off strategy, for several scenarios concerning the observability of the adoption of the clean technology and the cost of adopting it. We also show that the optimal inspection policy induces the firm to adopt the clean technology if the adoption cost is not too high, but the cost levels for which the firm adopts it depend on the scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within last few years a new type of instruments called Terrestrial Laser Scanners (TLS) entered to the commercial market. These devices brought a possibility to obtain completely new type of spatial, three dimensional data describing the object of interest. TLS instruments are generating a type of data that needs a special treatment. Appearance of this technique made possible to monitor deformations of very large objects, like investigated here landslides, with new quality level. This change is visible especially with relation to the size and number of the details that can be observed with this new method. Taking into account this context presented here work is oriented on recognition and characterization of raw data received from the TLS instruments as well as processing phases, tools and techniques to do them. Main objective are definition and recognition of the problems related with usage of the TLS data, characterization of the quality single point generated by TLS, description and investigation of the TLS processing approach for landslides deformation measurements allowing to obtain 3D deformation characteristic and finally validation of the obtained results. The above objectives are based on the bibliography studies and research work followed by several experiments that will prove the conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest article descriu els sensors enzimàtics i immunosensors electroquímics que s’han desenvolupat als nostres grups per a la detecció de la biotoxina marina àcid okadaic (OA), i discuteix la possibilitat d’integrar-los en programes de seguiment. Els sensors enzimàtics per a OA que es presenten es basen en la inhibició de la proteïna fosfatasa (PP2A) per aquesta toxina i la mesura electroquímica de l’activitat enzimàtica mitjançant l’ús de substrats enzimàtics apropiats, electroquímicament actius després de la seva desfosforació per l’enzim. Els immunosensors electroquímics descrits en aquest article es basen en un enzimoimmunoassaig sobre fase sòlida competitiu indirecte (ciELISA), amb fosfatasa alcalina (ALP) o peroxidasa (HRP) com a marcatges, i un sistema de reciclatge enzimàtic amb diaforasa (DI). Els biosensors presentats aquí s’han aplicat a l’anàlisi de dinoflagel·lats, musclos i ostres. Les validacions preliminars amb assaigs colorimètrics i LC-MS/MS han demostrat la possibilitat d’utilitzar les bioeines desenvolupades per al cribratge preliminar de biotoxines marines en mostres de camp o de cultiu, que ofereixen informació complementària a la cromatografia. En conclusió, tot i que encara cal optimitzar alguns paràmetres experimentals, la integració dels biosensors a programes de seguiment és viable i podria proporcionar avantatges respecte a altres tècniques analítiques pel que fa al temps d’anàlisi, la simplicitat, la selectivitat, la sensibilitat, el fet de poder ser d’un sol ús i l’efectivitat de cost. This article describes the electrochemical enzyme sensors and immunosensors that have been developed by our groups for the detection of marine biotoxin okadaic acid (OA), and discusses the possibility of integrating them into monitoring programmes. The enzyme sensors for OA reported herein are based on the inhibition of immobilised protein phosphatase 2A (PP2A) by this toxin and the electrochemical measurement of the enzyme activity through the use of appropriate enzyme substrates, which are electrochemically active after dephosphorylation by the enzyme. The electrochemical immunosensors described in this article are based on a competitive indirect Enzyme- Linked ImmunoSorbent Assay (ciELISA), using alkaline phosphatase (ALP) or horseradish peroxidase (HRP) as labels, and an enzymatic recycling system with diaphorase (DI). The biosensors presented herein have been applied to the analysis of dinoflagellates, mussels and oysters. Preliminary validations with colorimetric assays and LC-MS/MS have demonstrated the possibility of using the developed biotools for the preliminary screening of marine biotoxins in field or cultured samples, offering complementary information to chromatography. In conclusion, although optimisation of some experimental parameters is still required, the integration of biosensors into monitoring programmes is viable and may provide advantages over other analytical techniques in terms of analysis time, simplicity, selectivity, sensitivity, disposability of electrodes and cost effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the delegation of contracting capacity in a moral hazard environment with sequential production in a project which involves a principal and two agents. The agent in charge of the …nal production can obtain soft information about the other agent's effort choice by investing in monitoring. I investigate the circumstances under which it is optimal for the principal to use a centralized organization in which she designs the contracts with both agents or to use a decentralized organization in which she contracts only one agent, and delegates the power to contract the other agent. It is shown that in this setting a decentralized organization can be superior to a centralized organization. This is because the principal is better off under monitoring and the incentives for an agent to invest in monitoring can be higher in a decentralized organization. The circumstances under which this is true are related to the monitoring costs and the importance of each agent for production. The results explain the recent application of the design-build method in public procurement. Journal of Economic Literature Classi…cation Numbers: D23, D82, L14, L22. Keywords: Decentralization of Contracting, Monitoring, Moral Hazard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research project analyzes the reactions the teacher has on students' responses. Different techniques as discourse markers, types of questions and repair sequences are taken into account, but the author puts a special emphasis on non-verbal communication. To be aware of all these ways of reacting in a class interaction is essential for an adequate task monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies frequent monitoring in an infinitely repeated game with imperfect public information and discounting, where players observe the state of a continuous time Brownian process at moments in time of length _. It shows that a limit folk theorem can be achieved with imperfect public monitoring when players monitor each other at the highest frequency, i.e., _. The approach assumes that the expected joint output depends exclusively on the action profile simultaneously and privately decided by the players at the beginning of each period of the game, but not on _. The strong decreasing effect on the expected immediate gains from deviation when the interval between actions shrinks, and the associated increase precision of the public signals, make the result possible in the limit. JEL: C72/73, D82, L20. KEYWORDS: Repeated Games, Frequent Monitoring, Public Monitoring, Brownian Motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper study repeated games where the time repetitions of the stage game are not known or controlled by the players. We call this feature random monitoring. Kawamori's (2004) shows that perfect random monitoring is always better than the canonical case. Surprisingly, when the monitoring is public, the result is less clear-cut and does not generalize in a straightforward way. Unless the public signals are sufficiently informative about player's actions and/or players are patient enough. In addition to a discount effect, that tends to consistently favor the provision of incentives, we found an information effect, associated with the time uncertainty on the distribution of public signals. Whether payoff improvements are or not possible, depends crucially on the direction and strength of these effects. JEL: C73, D82, D86. KEYWORDS: Repeated Games, Frequent Monitoring, Random Public Monitoring, Moral Hazard, Stochastic Processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabajo de presentación en formato PowerPoint del TFC NetEye- Zabbix, network monitoring implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of resource management is the efficient and effective use of network resources, for instance bandwidth. In this article, a connection oriented network scenario is considered, where a certain amount of bandwidth is reserved for each label switch path (LSP), which is a logical path, in a MPLS or GMPLS environment. Assuming there is also some kind of admission control (explicit or implicit), these environments typically provide quality of service (QoS) guarantees. It could happen that some LSPs become busy, thus rejecting connections, while other LSPs may be under-utilised. We propose a distributed lightweight monitoring technique, based on threshold values, the objective of which is to detect congestion when it occurs in an LSP and activate the corresponding alarm which will trigger a dynamic bandwidth reallocation mechanism

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Con este proyecto se pretende implementar en un entorno real la herramienta Zabbix de monitoring de red. La idea es realizar un estudio de las necesidades, instalar la plataforma base, comprobar con ejemplos reales que la plataforma cumple con las necesidades corporativas y por último diseñar el plan de acción para el despliegue final a la organización.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquesta tesi explora la possibilitat de fer servir enllaços inductius per a una aplicació de l’automòbil on el cablejat entre la centraleta (ECU) i els sensors o detectors és difícil o impossible. S’han proposat dos mètodes: 1) el monitoratge de sensors commutats (dos possibles estats) via acoblament inductiu i 2) la transmissió mitjançant el mateix principi físic de la potència necessària per alimentar els sensors autònoms remots. La detecció d'ocupació i del cinturó de seguretat per a seients desmuntables pot ser implementada amb sistemes sense fils passius basats en circuits ressonants de tipus LC on l'estat dels sensors determina el valor del condensador i, per tant, la freqüència de ressonància. Els canvis en la freqüència són detectats per una bobina situada en el terra del vehicle. S’ha conseguit provar el sistema en un marge entre 0.5 cm i 3 cm. Els experiments s’han dut a terme fent servir un analitzador d’impedàncies connectat a una bobina primària i sensors comercials connectats a un circuit remot. La segona proposta consisteix en transmetre remotament la potència des d’una bobina situada en el terra del vehicle cap a un dispositiu autònom situat en el seient. Aquest dispositiu monitorarà l'estat dels detectors (d'ocupació i de cinturó) i transmetrà les dades mitjançant un transceptor comercial de radiofreqüència o pel mateix enllaç inductiu. S’han avaluat les bobines necessàries per a una freqüència de treball inferior a 150 kHz i s’ha estudiat quin és el regulador de tensió més apropiat per tal d’aconseguir una eficiència global màxima. Quatre tipus de reguladors de tensió s’han analitzat i comparat des del punt de vista de l’eficiència de potència. Els reguladors de tensió de tipus lineal shunt proporcionen una eficiència de potència millor que les altres alternatives, els lineals sèrie i els commutats buck o boost. Les eficiències aconseguides han estat al voltant del 40%, 25% i 10% per les bobines a distàncies 1cm, 1.5cm, i 2cm. Les proves experimentals han mostrat que els sensors autònoms han estat correctament alimentats fins a distàncies de 2.5cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

First discussion on compositional data analysis is attributable to Karl Pearson, in 1897. However, notwithstanding the recent developments on algebraic structure of the simplex, more than twenty years after Aitchison’s idea of log-transformations of closed data, scientific literature is again full of statistical treatments of this type of data by using traditional methodologies. This is particularly true in environmental geochemistry where besides the problem of the closure, the spatial structure (dependence) of the data have to be considered. In this work we propose the use of log-contrast values, obtained by asimplicial principal component analysis, as LQGLFDWRUV of given environmental conditions. The investigation of the log-constrast frequency distributions allows pointing out the statistical laws able togenerate the values and to govern their variability. The changes, if compared, for example, with the mean values of the random variables assumed as models, or other reference parameters, allow definingmonitors to be used to assess the extent of possible environmental contamination. Case study on running and ground waters from Chiavenna Valley (Northern Italy) by using Na+, K+, Ca2+, Mg2+, HCO3-, SO4 2- and Cl- concentrations will be illustrated

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.