75 resultados para SQUARE RESONATORS

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Com o presente estudo pretendeu-se: (1) verificar se a ligadura funcional para a lesão da articulação Acrómio-Clavicular (AC), descrita por Chanussot e Danowski (2001), contribui para o restabelecimento da força muscular num paciente com lesão grau III; e, (2) observar se a ligadura funcional altera o padrão electromiográfico dos principais músculos superficiais do complexo articular do ombro: infra-espinhoso, deltóide anterior, grande peitoral, trapézio superior e trapézio inferior. Efectuou-se assim um estudo de caso do tipo observacional, descritivo transversal. Para avaliação da força muscular foi utilizado um dinamómetro isocinético e para a avaliação do nível de activação de fibras musculares foi utilizada a EMG de superfície. Os movimentos em análise foram os de rotação interna e externa, a 60º/s e 180º/s. Os resultados revelaram, na presença de ligadura, um aumento do Peak Torque dos rotadores internos, assim como da actividade do grande peitoral e trapézio inferior. Constatou-se ainda uma diminuição do Peak Torque e da percentagem do Root Mean Square do trapézio inferior, trapézio superior e grande peitoral, do ombro esquerdo, sem ligadura, quando comparado com o ombro contralateral. A ligadura funcional, numa entorse da acromio-clavicular grau III, poderá contribuir para a recuperação de força muscular e activação de fibras musculares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Insuficiência Cardíaca (IC), como uma doença crónica, tem vindo a ser alvo de análise devido ao seu impacto, não só a nível económico, mas também a nível da qualidade de vida (QV). Vários estudos demonstram que os doentes com IC apresentam um comprometimento da QV, em várias dimensões. OBJETIVO: Descrever a QV dos doentes com IC do Centro Hospitalar Tâmega e Sousa (CHTS). METODOLOGIA: O estudo é quantitativo, transversal, prospetivo e descritivo. Foi aplicado, entre janeiro a junho de 2012, o Euro Quality of Life Instrument-5D (EQ-5D) para avaliar o estado de saúde (ES) e o Kansas City Cardiomyopathy Questionnaire (KCCQ) para avaliar a QV de 326 doentes com IC, dos quais 226 seguidos na Consulta Externa (77,9% masculinos, idade média 67,5 ±11,6 anos, desvio padrão) e 100 na Clínica de IC (CIC) (73,0% masculinos, idade média 59,0 anos, desvio padrão ±12,7). Foi usada a estatística descritiva, teste t, qui quadrado e a análise da variância. RESULTADOS: Os doentes do género feminino, do grupo etário 75-100 anos, solteiros, divorciados, separados ou viúvos, que não sabem ler nem escrever, sem apoio dos amigos e sem condições económicas mínimas para o tratamento da IC apresentaram pior ES e QV. Os doentes submetidos à terapia de ressincronização cardíaca e às cirurgias valvular e de revascularização tiveram melhor QV. Os doentes com IC de etiologia isquémica e em classe III-IV da New York Heart Association apresentaram pior ES. Nestas classes e com fração de ejeção ≤35% os doentes tiveram pior QV. Os doentes da CIC evidenciaram melhor ES e QV. CONCLUSÕES: A QV dos doentes com IC do CHTS é influenciada pelos fatores pessoais, clínicos e pelo local de intervenção. É fundamental mensurar a QV, na prática clínica, para evidenciar a perceção do ES dos doentes e o impacto da IC na QV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O declínio do equilíbrio, da força dos membros inferiores e o medo de cair são fatores de risco de queda associados ao envelhecimento e a sua avaliação pode ser realizada pelo teste One Leg Standing (OLS), Sit to Stand (STS) e pela Falls Eficacy Scale (FES), respetivamente. As aplicações para smartphone constituem uma alternativa para a avaliação dos fatores de risco de queda no envelhecimento. Objetivo: Analisar a capacidade de uma aplicação para smartphone na avaliação dos testes STS, OLS e FES. Metodologia: Realizou-se um estudo analítico numa amostra de 27 voluntários com idade ≥ 60 anos. Realizaram-se os testes STS, OLS e a FES (versão iconográfica, apresentada no smartphone). Os dados foram recolhidos simultaneamente por um smartphone e pelo Qualisys Motion Capture Systems associado a uma plataforma de forças. Foi utilizado o r de Pearson ou Spearman para analisar as possíveis correlações. Resultados: No STS obteve-se uma correlação muito forte (rp=0.97) no número de repetições de ciclos Sit Stand Sit (SLS) e forte na duração média do SLS (rp=0.85) e das subfases Sit to Stand (rp=0.69) e Stand to Sit (rp=0.778), com p<0.001. As medidas de inclinação do tronco apresentaram correlações fortes, com exceção do ângulo inicial (p≥0.05). No OLS, verificou-se uma correlação moderada entre o deslocamento do centro de pressão peak to peak médio-lateral (rs=0.45; p=0.017) e antero-posterior (rs=0.39; p=0.046), root mean square médio-lateral (rs=0.39; p=0.046) e antero-posterior (rs=0.46; p=0.017) e área do estatocinesiograma (rs=0.45; p=0.018). Na FES obteve-se uma correlação moderada em três categorias: ‘tomar banho/duche’ (rs=0.49; p=0.010), ‘deitar/levantar da cama (rs=0.43; p=0.024) e ‘chegar aos armários’ (rs=0.38; p=0.050). Conclusão: A aplicação para smartphone parece avaliar corretamente os ciclos e a variação da inclinação do tronco no STS, porém parece necessitar de ser reajustada na FES e na velocidade do deslocamento do centro de pressão, no OLS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an imminent need for rapid methods to detect and determine pathogenic bacteria in food products as alternatives to the laborious and time-consuming culture procedures. In this work, an electrochemical immunoassay using iron/gold core/shell nanoparticles (Fe@Au) conjugated with anti-Salmonella antibodies was developed. The chemical synthesis and functionalization of magnetic and gold-coated magnetic nanoparticles is reported. Fe@Au nanoparticles were functionalized with different self-assembled monolayers and characterized using ultraviolet-visible spectrometry, transmission electron microscopy, and voltammetric techniques. The determination of Salmonella typhimurium, on screen-printed carbon electrodes, was performed by square-wave anodic stripping voltammetry through the use of CdS nanocrystals. The calibration curve was established between 1×101 and 1×106 cells/mL and the limit of detection was 13 cells/mL. The developed method showed that it is possible to determine the bacteria in milk at low concentrations and is suitable for the rapid (less than 1 h) and sensitive detection of S. typhimurium in real samples. Therefore, the developed methodology could contribute to the improvement of the quality control of food samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, it was evaluated the total antioxidant capacity (TAC) of beverages using an electrochemical biosensor. The biosensor consisted on the purine base (guanine or adenine) electro-immobilization on a glassy carbon electrode surface (GCE). Purine base damage was induced by the hydroxyl radical generated by Fenton-type reaction. Five antioxidants were applied to counteract the deleterious effects of the hydroxyl radical. The antioxidants used were ascorbic acid, gallic acid, caffeic acid, coumaric acid and resveratrol. These antioxidants have the ability to scavenger the hydroxyl radical and protect the guanine and adenine immobilized on the GCE surface. The interaction carried out between the purinebase immobilized and the free radical in the absence and presence of antioxidants was evaluated by means of changes in the guanine and adenine anodic peak obtained by square wave voltammetry (SWV). The results demonstrated that the purine-biosensors are suitable for rapid assessment of TAC in beverages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disposable screen-printed electrodes (SPCE) were modified using a cosmetic product to partially block the electrode surface in order to obtain a microelectrode array. The microarrays formed were electropolymerized with aniline. Scanning electron microscopy was used to evaluate the modified and polymerized electrode surface. Electrochemical characteristics of the constructed sensor for cadmium analysis were evaluated by cyclic and square-wave voltammetry. Optimized stripping procedure in which the preconcentration of cadmium was achieved by depositing at –1.20 V (vs. Ag/AgCl) resulted in a well defined anodic peak at approximately –0.7 V at pH 4.6. The achieved limit of detection was 4 × 10−9 mol dm−3. Spray modified and polymerized microarray electrodes were successfully applied to quantify cadmium in fish sample digests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho tem como objectivo o desenvolvimento de um método analítico, baseado na voltametria de onda quadrada (SWV), para a análise de ciprofloxacina (CIP) em produtos farmacêuticos e em processos de remediação. Para o desenvolvimento do método voltamétrico foram utilizadas duas células voltamétricas: a célula clássica (utilizando um eléctrodo de trabalho de carbono vítreo - GCE) e um eléctrodo de carbono impresso (SPCE). Após a optimização dos parâmetros da SWV, pH (3,04), frequência (400Hz), incremento de potencial (6 mV) e amplitude do impulso de potencial (40 mV), procedeu-se a validação dos métodos, obtendo-se zonas lineares entre a concentração de CIP e a intensidade de corrente de pico de 5,0×10-6 a 6,0×10-5 mol/L (GCE) e de 1,0×10-5 a 4,0×10-5 mol/L (SPCE) e limites de detecção de 9,48×10-6 mol/L (GCE) e 2,13×10-6 mol/L (SPCE). Verificou-se que a sensibilidade, a precisão e a selectividade são superiores para o SPCE, sendo por isso esta a célula mais adequada para proceder à análise da CIP em produtos farmacêuticos. O SPCE foi aplicado com sucesso à análise de CIP num produto farmacêutico. Para o tratamento de soluções aquosas contendo a CIP foram testados dois oxidantes: o permanganato de potássio e o peróxido de hidrogénio. Para o peróxido de hidrogénio os resultados obtidos foram inconclusivos. No caso do permanganato de potássio, os resultados mostram que a degradação da ciprofloxacina depende da concentração do oxidante. Para uma concentração de CIP de 3,00×10-4 mol/L uma degradação rápida foi obtida com o uso de 6,00×10-3 mol/L de permanganato de potássio. Na aplicação do permanganato na remediação de solos verificou-se que no caso de solos húmicos a ciprofloxacina é adsorvida pelo solo, não sendo possível confirmar a ocorrência da reacção de degradação. No caso de solos arenosos verificou-se que a ciprofloxacina foi rapidamente degradada pelo permanganato de potássio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A eletromiografia é, hoje em dia, uma das técnicas mais utilizadas no estudo dos músculos, estando presente em áreas como a medicina, a biomecânica e a fisiologia, possibilitando o desenvolvimento científico e contribuindo para proporcionar melhorias na qualidade da vida humana. Sendo assim, este trabalho apresenta um protótipo de um aparelho de aquisição de sinais eletromiográficos, explicando também toda a teoria, técnicas, componentes utilizadas e softwares que estiveram presentes na sua implementação. De uma forma sucinta, para a aquisição do sinal eletromiográfico usou-se uma placa de aquisição NI-USB 6009 e para a visualização do mesmo recorreu-se ao software LabVIEW. Para validar o sinal adquirido com o equipamento desenvolvido, utilizou-se um outro equipamento, o Biopac MP36 Student Lab System, fazendo-se assim recolhas de sinais eletromiográficos com ambos os equipamentos. Os sinais recolhidos pelos dois equipamentos foram analisados no software Acknowledge 3.9.0 (Biopac Systems, Inc.), podendo observar-se os espetros de frequência correspondentes a cada sinal e retirar valores para posterior análise estatística. Feita essa análise, concluiu-se que não foram detetadas diferenças significativas entre os sinais eletromiográficos recolhidos com ambos os equipamentos, validando-se assim, o equipamento desenvolvido.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

D. João de Magalhães e Avelar (1754-1833) formou aquela que, ao tempo, era a maior biblioteca privada portuguesa. Com cerca de 36000 volumes, foi elogiada por personalidades nacionais e estrangeiras, por aliar à quantidade de volumes inúmeros e valiosíssimos manuscritos. Formada ao longo dos séculos XVIII e XIX, durante mais de 30 anos, originou, em 1833, o primeiro núcleo da actual Biblioteca Pública Municipal do Porto. Numa época em que possuir livros era sinónimo de prestígio social mas num período em que quase não havia tradição de bibliotecas públicas no nosso país, contrariamente ao que acontecia noutras realidades, a livraria privada de Avelar formou, com outras, a Real Biblioteca Pública da Cidade do Porto. Em 1833, aquando do primeiro aniversário da entrada do exército liberal no Porto, por decreto, criou-se a biblioteca portuense. Estabelecida na casa que servia de Hospício dos Religiosos de Santo António do Val da Piedade, à praça da Cordoaria, tinha como objectivo satisfazer a utilidade pública, estando aberta todos os dias, excepto domingos e feriados. Propriedade da cidade do Porto, ficava sujeita à administração da Câmara que se obrigava à sua guarda, manutenção, conservação, bem como à constante aquisição de espólio. Como veremos, tratou-se de um processo conflituoso mas o Porto obtinha, definitivamente, a sua biblioteca pública.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of the hydrolysis products of oxadiazon was studied by cyclic and square-wave voltammetry using a glassy carbon electrode. Maximum currents were obtained at pH 12.8 in an aqueous electrolyte solution containing 30% ethanol and the current did not decrease with time showing that there was little adsorption of the reaction products on the electrode surface. The hydrolysis products of oxadiazon were identi®ed, after isolation and puri®cation, as 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl)-2-ethoxycarbonylhydrazine (Oxa1) and 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) with redox potentials 0.6Vand 70.1V (vs. Ag=AgCl), respectively. Based on the electrochemical behavior of 1-trimethylacetyl-2-(2,4-dichloro-5-isopropoxyphenyl) hydrazine (Oxa2) a simple electroanalytical procedure was developed for the determination of oxadiazon in commercial products used in the treatment of rice crops in Portugal that contain oxadiazon as the active ingredient. The detection limit was 161074 M, the mean content and relative standard deviation obtained for seven samples of two different commercial products by the electrochemical method were 28.4 0.8% (Ronstar) and 1.9 0.2% (Ronstar GR), and the recoveries were 100.3 5.4% and 101.1 5.3 %, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrooxidative behavior of citalopram (CTL) in aqueous media was studied by cyclic voltammetry (CV) and square-wave voltammetry (SWV) at a glassy-carbon electrode. The electrochemical behaviour of CTL involves two electrons and two protons in the irreversible and diffusion controlled oxidation of the tertiary amine group. The maximum analytical signal was obtained in a phosphate buffer (pH ¼ 8.2). For analytical purposes, an SWV method and a flow-injection analysis (FIA) system with amperometric detection were developed. The optimised SWV method showed a linear range between 1.10 10 5–1.20 10 4 molL 1, with a limit of detection (LOD) of 9.5 10 6 molL 1. Using the FIA method, a linear range between 2.00 10 6–9.00 10 5 molL 1 and an LODof 1.9 10 6 molL 1 were obtained. The validation of both methods revealed good performance characteristics confirming applicability for the quantification of CTL in several pharmaceutical products.