Square-wave adsorptive-stripping voltammetric detection in the quality control of fluoxetine


Autoria(s): Nouws, Henri P. A.; Delerue-Matos, Cristina; Barros, Aquiles A.; Rodrigues, José A.; Santos-Silva, Alice; Borges, Fernanda
Data(s)

26/11/2013

26/11/2013

2007

Resumo

Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.

Identificador

DOI: 10.1080/00032710701297059

0003-2719

1532-236X

http://hdl.handle.net/10400.22/2964

Idioma(s)

eng

Publicador

Taylor & Francis

Relação

Analytical Letters; Vol. 40, Issue 6

http://www.tandfonline.com/doi/abs/10.1080/00032710701297059#.UpTIp0r6Q25

Direitos

openAccess

Palavras-Chave #Fluoxetine #Square-wave adsorptive-stripping voltammetry #Flow-injection analysis #Electrochemical detection #Drug dissolution
Tipo

article