20 resultados para Phasor measurement units.

em Instituto Politécnico do Porto, Portugal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

13th International Conference on Autonomous Robot Systems (Robotica), 2013, Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best places to locate the Gas Supply Units (GSUs) on a natural gas systems and their optimal allocation to loads are the key factors to organize an efficient upstream gas infrastructure. The number of GSUs and their optimal location in a gas network is a decision problem that can be formulated as a linear programming problem. Our emphasis is on the formulation and use of a suitable location model, reflecting real-world operations and constraints of a natural gas system. This paper presents a heuristic model, based on lagrangean approach, developed for finding the optimal GSUs location on a natural gas network, minimizing expenses and maximizing throughput and security of supply.The location model is applied to the Iberian high pressure natural gas network, a system modelised with 65 demand nodes. These nodes are linked by physical and virtual pipelines – road trucks with gas in liquefied form. The location model result shows the best places to locate, with the optimal demand allocation and the most economical gas transport mode: by pipeline or by road truck.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natural gas industry has been confronted with big challenges: great growth in demand, investments on new GSUs – gas supply units, and efficient technical system management. The right number of GSUs, their best location on networks and the optimal allocation to loads is a decision problem that can be formulated as a combinatorial programming problem, with the objective of minimizing system expenses. Our emphasis is on the formulation, interpretation and development of a solution algorithm that will analyze the trade-off between infrastructure investment expenditure and operating system costs. The location model was applied to a 12 node natural gas network, and its effectiveness was tested in five different operating scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the energy management of the isolated operation of small power system, the economic scheduling of the generation units is a crucial problem. Applying right timing can maximize the performance of the supply. The optimal operation of a wind turbine, a solar unit, a fuel cell and a storage battery is searched by a mixed-integer linear programming implemented in General Algebraic Modeling Systems (GAMS). A Virtual Power Producer (VPP) can optimal operate the generation units, assured the good functioning of equipment, including the maintenance, operation cost and the generation measurement and control. A central control at system allows a VPP to manage the optimal generation and their load control. The application of methodology to a real case study in Budapest Tech, demonstrates the effectiveness of this method to solve the optimal isolated dispatch of the DC micro-grid renewable energy park. The problem has been converged in 0.09 s and 30 iterations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo do presente trabalho foi caracterizar os condensados produzidos numa fábrica de pasta para papel para identificar e localizar pontos da sua contaminação. Para o efeito, foram recolhidas amostras de condensado e caracterizados os parâmetros condutividade, pH, sódio e sílica. A amostragem decorreu no período entre 15 de Setembro a 6 de Novembro de 2008. Através da análise dos resultados obtidos para as concentrações de sílica e de sódio de cada uma das correntes, foram identificadas como contaminadas as correntes de condensado provenientes do condensador do Turbogerador 4, da área dos Digestores Descontínuos, da Evaporação e do Aquecedor de Água Quente para o Branqueamento. A realização de um balanço pontual à sílica no tanque de condensados da Central permitiu concluir que a maior contribuição advém do condensador do Turbogerador 4. Na Evaporação ocorre contaminação do condensado quando as secções do Concentrador 1 são colocadas em serviço após lavagem. Durante o acompanhamento do arranque da Evaporação, uma das secções (1/B) registou um valor máximo na concentração de sódio no condensado de 135 mg/L Na. Do estudo resulta, enquanto não for reparado e/ou substituído o equipamento responsável pelas contaminações, a necessidade de admitir requisitos para controlo da qualidade da água da caldeira menos restritivos, nomeadamente para a razão sódio/fosfato. É necessário, contudo, o rigoroso acompanhamento da qualidade da água da caldeira (pH, sobretudo) para prevenir afastamentos inesperados dos limites de controlo. Durante a realização deste trabalho foram identificadas algumas situações a melhorar, tais como a uniformização dos valores de desvio para esgoto dos condensados e das unidades utilizadas, a adequação das escalas dos aparelhos de medida para as gamas de leitura de interesse, a verificação e calibração periódica do equipamento instalado em linha, a adopção do parâmetro “Sódio” para controlo da qualidade dos condensados, a instalação de sistemas de amostragem com arrefecimento em todas as correntes de condensados e a reparação ou substituição de algum equipamento instalado em linha que se encontra em muito mau estado e ainda a manutenção do equipamento mantendo-o em boas condições de limpeza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solvent extraction is considered as a multi-criteria optimization problem, since several chemical species with similar extraction kinetic properties are frequently present in the aqueous phase and the selective extraction is not practicable. This optimization, applied to mixer–settler units, considers the best parameters and operating conditions, as well as the best structure or process flow-sheet. Global process optimization is performed for a specific flow-sheet and a comparison of Pareto curves for different flow-sheets is made. The positive weight sum approach linked to the sequential quadratic programming method is used to obtain the Pareto set. In all investigated structures, recovery increases with hold-up, residence time and agitation speed, while the purity has an opposite behaviour. For the same treatment capacity, counter-current arrangements are shown to promote recovery without significant impairment in purity. Recycling the aqueous phase is shown to be irrelevant, but organic recycling with as many stages as economically feasible clearly improves the design criteria and reduces the most efficient organic flow-rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel biomimetic sensor for the potentiometric transduction of oxytetracycline is presented. The artificial host was imprinted in methacrylic acid and/or acrylamide based polymers. Different amounts of molecularly imprinted and non-imprinted polymers were dispersed in different plasticizing solvents and entrapped in a poly(vinyl chloride) matrix. Only molecularly imprinted based sensors allowed a potentiometric transduction, suggesting the existence of host–guest interactions. These sensors exhibited a near-Nernstian response in steady state evaluations; slopes and detection limits ranged 42–63 mV/decade and 2.5–31.3 µg/mL, respectively. Sensors were independent from the pH of test solutions within 2–5. Good selectivity was observed towards glycine, ciprofloxacin, creatinine, acid nalidixic, sulfadiazine, cysteine, hydroxylamine and lactose. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ±0.7%), fast response, good sensitivity (65 mV/decade), wide linear range (5.0×10−5 to 1.0×10−2 mol/L), low detection limit (19.8 µg/mL), and a stable baseline for a 5×10−3M citrate buffer (pH 2.5) carrier. The sensors were successfully applied to the analysis of drugs and urine. This work confirms the possibility of using molecularly imprinted polymers as ionophores for organic ion recognition in potentiometric transduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to show how it is possible to integrate stories and ICT in Content Language Integrated Learning (CLIL) for English as a foreign language (EFL) learning in bilingual schools. Two Units of Work are presented. One, for the second year of Primary, is based on a Science topic, ‘Materials’. The story used is ‘The three little pigs’ and the computer program ‘JClic’. The other one is based on a Science and Arts topic for the sixth year of Primary, the story used is ‘Charlotte’s Web’ and the computer program ‘Atenex’.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Satisfação no trabalho, definida como reações individuais, cognitivas, afetivas e avaliativas perante o trabalho (Locke, 1983), tem sido amplamente estudada no âmbito das organizações. A sua medição na área da saúde contribui para incrementar um bom ambiente na prática e bem-estar dos profissionais e para aumentar a qualidade dos cuidados. Em 2006 surge um novo contexto de trabalho através da criação da RNCCI, que pretende fazer face ao crescente aumento de população em situação de dependência ou incapacidade, mas também aliviar a sobrecarga e custos associados aos cuidados hospitalares. A reorganização do trabalho nas unidades de cuidados continuados acenta nos princípios da interdisciplinariedade e cooperação entre a equipa, requerendo mudança e adaptação à prática. Sendo os enfermeiros a classe profissional com maior tempo de contacto nos cuidados, importa verificar se estão satisfeitos com a mudança induzida. Assim, este estudo de natureza quantitativa pretende medir e analisar a satisfação profissional ddos enfermeiros que trabalham no serviço de longa duração e manutenção nas unidades de cuidados continuados do distrito de Braga, e verificar se esta variável é influenciada por fatores sociodemográficos e laborais. Para a recolha de dados utiliza-se a Escala de Avaliação da Satisfação no Trabalho para Enfermeiros - EASPE© (α=0,814) e um questionário sociodemográfico e profissional. A análise dos dados é efetuada com recurso à estatística descritiva e inferencial com utilização dos testes de Mann-Whitney e de Kruskal-Wallis. Os resultados obtidos evidenciam que os enfermeiros apresentam um nível de satisfação global no trabalho positivo, mas negativo nas dimensões satisfação com benefícios e recompensas e satisfação com promoção. Conclui-se, ainda, que a satisfação com promoção é influenciada pelas habilitações literárias, que a satisfação com a comunicação é influenciada pela remuneração, que a satisfação com benefícios e recompensas é influenciada pelo horário semanal e que a unidade de cuidados é determinante na satisfação global no trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering tobacco smoke as one of the most health-relevant indoor sources, the aim of this work was to further understand its negative impacts on human health. The specific objectives of this work were to evaluate the levels of particulate-bound PAHs in smoking and non-smoking homes and to assess the risks associated with inhalation exposure to these compounds. The developed work concerned the application of the toxicity equivalency factors approach (including the estimation of the lifetime lung cancer risks, WHO) and the methodology established by USEPA (considering three different age categories) to 18 PAHs detected in inhalable (PM10) and fine (PM2.5) particles at two homes. The total concentrations of 18 PAHs (ΣPAHs) was 17.1 and 16.6 ng m−3 in PM10 and PM2.5 at smoking home and 7.60 and 7.16 ng m−3 in PM10 and PM2.5 at non-smoking one. Compounds with five and six rings composed the majority of the particulate PAHs content (i.e., 73 and 78 % of ΣPAHs at the smoking and non-smoking home, respectively). Target carcinogenic risks exceeded USEPA health-based guideline at smoking home for 2 different age categories. Estimated values of lifetime lung cancer risks largely exceeded (68–200 times) the health-based guideline levels at both homes thus demonstrating that long-term exposure to PAHs at the respective levels would eventually cause risk of developing cancer. The high determined values of cancer risks in the absence of smoking were probably caused by contribution of PAHs from outdoor sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of an exploratory study on knowledge management in Portuguese organizations. The study was based on a survey sent to one hundred of the main Portuguese organizations, in order to know their current practices relating knowledge management systems (KMS) usage and intellectual capital (IC) measurement. With this study, we attempted to understand what are the main tools used to support KM processes and activities in the organizations, and what metrics are pointed by organizations to measure their knowledge assets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of competitive electricity markets has changed the consumers’ and distributed generation position power systems operation. The use of distributed generation and the participation in demand response programs, namely in smart grids, bring several advantages for consumers, aggregators, and system operators. The present paper proposes a remuneration structure for aggregated distributed generation and demand response resources. A virtual power player aggregates all the resources. The resources are aggregated in a certain number of clusters, each one corresponding to a distinct tariff group, according to the economic impact of the resulting remuneration tariff. The determined tariffs are intended to be used for several months. The aggregator can define the periodicity of the tariffs definition. The case study in this paper includes 218 consumers, and 66 distributed generation units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem dois objetivos, o primeiro é a realização de uma auditoria energética e avaliação da qualidade do ar às instalações de uma Piscina Municipal, permitindo a sua classificação energética, e o segundo é o estudo de propostas de melhoria que contribuam para uma melhor eficiência energética do edifício. Na análise à qualidade do ar interior os parâmetros avaliados encontravam-se todos dentro dos limites estabelecidos por lei, com exceção dos valores de COVs que em dois pontos de medição (ambos na nave) ultrapassaram os limites estabelecidos por lei. A auditoria ao edifício permitiu verificar que o caudal mínimo de água nova nas piscinas imposto por lei é cumprido pela instalação. No que diz respeito ao caudal de ar novo introduzido, este apenas é respeitado quando a unidade de tratamento de ar está a debitar 100% da sua capacidade. Quando a unidade opera a 50% da sua capacidade apresenta um défice de 5% do valor mínimo estabelecido. Relativamente às perdas energéticas associadas aos tanques de natação, estas apresentam um valor de 95,89 kW, em que 59,09 kW dizem respeito às perdas por evaporação. Foi também possível concluir que as perdas por evaporação representam cerca de 39% da energia calorifica produzida nas caldeiras. O edifício apresenta um consumo anual de eletricidade de 166 482 kWh em que 69% deste valor é provocado pelas unidades de tratamento de ar e a iluminação apresenta apenas um peso de 3%. Em relação ao gás natural consumido pelas caldeiras o seu valor anual é de 1 317 240 kWh. A simulação dinâmica do edifício permitiu concluir que este apresenta um IEE de 1 269,9 kWh/m2.ano. O rácio de classe energética (RIEE) é de 1,24 o que significa que o edifício pertence à classe energética C. As medidas estudadas para a melhoria da eficiência energética, nomeadamente integração energética com uma central de ciclo combinado, aplicação de cobertura isotérmica nas piscinas e substituição do telhado na zona da nave, mostraram-se viáveis. O estudo da possibilidade da realização de uma integração energética permitiu concluir que a poupança anual é de 9 374 € e o investimento é recuperado em menos de 1,5 anos. Relativamente à aplicação de cobertura isotérmica o investimento é de 14 000 € e é recuperado em 2 anos. A substituição do telhado na zona da nave tem um investimento de 20 500 € e a recuperação realiza-se num período de 3,5 anos.