15 resultados para Empirical Mode Decomposition, vibration-based analysis, damage detection, signal decomposition
em Instituto Politécnico do Porto, Portugal
Resumo:
Purpose: This study investigated the influence of long-term wearing of unstable shoes (WUS) on compensatory postural adjustments (CPA) to an external perturbation. Methods: Participants were divided into two groups: one wore unstable shoes while the other wore conventional shoes for 8 weeks. The ground reaction force signal was used to calculate the anterior– posterior (AP) displacement of the centre of pressure (CoP) and the electromyographic signal of gastrocnemius medialis (GM), tibialis anterior (TA), rectus femoris (RF) and biceps femoris (BF) muscles was used to assess individual muscle activity, antagonist co-activation and reciprocal activation at the joint (TA/GM and RF/(BF + GM) pairs) and muscle group levels (ventral (TA + RF)/dorsal (GM + BF) pair) within time intervals typical for CPA. The electromyographic signal was also used to assess muscle latency. The variables described were evaluated before and after the 8-week period while wearing the unstable shoes and barefoot. Results: Long-term WUS led to: an increase of BF activity in both conditions (barefoot and wearing the unstable shoes); a decrease of GM activity; an increase of antagonist co-activation and a decrease of reciprocal activation level at the TA/GM and ventral/dorsal pairs in the unstable shoe condition. Additionally, WUS led to a decrease in CoP displacement. However, no differences were observed in muscle onset and offset. Conclusion: Results suggest that the prolonged use of unstable shoes leads to increased ankle and muscle groups’ antagonist co-activation levels and higher performance by the postural control system.
Resumo:
The purpose of this study is to analyse the interlimb relation and the influence of mechanical energy on metabolic energy expenditure during gait. In total, 22 subjects were monitored as to electromyographic activity, ground reaction forces and VO2 consumption (metabolic power) during gait. The results demonstrate a moderate negative correlation between the activity of tibialis anterior, biceps femoris and vastus medialis of the trailing limb during the transition between midstance and double support and that of the leading limb during double support for the same muscles, and between these and gastrocnemius medialis and soleus of the trailing limb during double support. Trailing limb soleus during the transition between mid-stance and double support was positively correlated to leading limb tibialis anterior, vastus medialis and biceps femoris during double support. Also, the trailing limb centre of mass mechanical work was strongly influenced by the leading limbs, although only the mechanical power related to forward progression of both limbs was correlated to metabolic power. These findings demonstrate a consistent interlimb relation in terms of electromyographic activity and centre of mass mechanical work, being the relations occurred in the plane of forward progression the more important to gait energy expenditure.
Resumo:
“Drilling of polymeric matrix composites structures”
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with square-wave adsorptive-stripping voltammetric detection (FIA-SWAdSV) were developed for the determination of fluoxetine (FXT). The methods were based on the reduction of FXT at a mercury drop electrode at -1.2 V versus Ag/AgCl, in a phosphate buffer of pH 12.0, and on the possibility of accumulating the compound at the electrode surface. The SWAdSV method was successfully applied in the quantification of FXT in pharmaceutical products, human serum samples, and in drug dissolution studies. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was possible to quantify FXT in several pharmaceutical products using FIA-SWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs.
Resumo:
Ao longo dos últimos anos, acompanhada da evolução tecnológica, da dificuldade da inspeção visual e da consciencialização dos efeitos de uma má inspeção, verificou-se uma maior sensibilidade para a importância da monitorização estrutural, principalmente nas grandes infra-estruturas de engenharia civil. Os sistemas de monitorização estrutural permitem o acompanhamento contínuo do comportamento de uma determinada estrutura de tal forma que com os dados obtidos, é possível avaliar alterações no comportamento da mesma. Com isso, tem-se desenvolvido e implementado estratégias de identificação de danos estruturais com o intuito de aumentar a fiabilidade estrutural e evitar precocemente que alterações na condição da estrutura possam evoluir para situações mais severas. Neste contexto, a primeira parte desta dissertação consiste numa introdução à monitorização estrutural e à deteção de dano estrutural. Relativamente à monitorização, são expostos os seus objetivos e os princípios da sua aplicação. Conjuntamente são apresentados e descritos os principais sensores e são explicadas as funcionalidades de um sistema de aquisição de dados. O segundo tema aborda a importância da deteção de dano introduzindo os métodos estudados neste trabalho. Destaca-se o método das linhas de influência, o método da curvatura dos modos de vibração e o método da transformada de wavelet. Na segunda parte desta dissertação são apresentados dois casos de estudo. O primeiro estudo apresenta uma componente numérica e uma componente experimental. Estuda-se um modelo de viga que se encontra submetida a vários cenários de dano e valida-se a capacidade do método das linhas de influência em detetar e localizar essas anomalias. O segundo estudo consiste na modelação numérica de uma ponte real, na posterior simulação de cenários de dano e na análise comparativa da eficácia de cada um dos três métodos de deteção de dano na identificação e localização dos danos simulados. Por último, são apresentadas as principais conclusões deste trabalho e são sugeridos alguns tópicos a explorar na elaboração de trabalhos futuros.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
Complex industrial plants exhibit multiple interactions among smaller parts and with human operators. Failure in one part can propagate across subsystem boundaries causing a serious disaster. This paper analyzes the industrial accident data series in the perspective of dynamical systems. First, we process real world data and show that the statistics of the number of fatalities reveal features that are well described by power law (PL) distributions. For early years, the data reveal double PL behavior, while, for more recent time periods, a single PL fits better into the experimental data. Second, we analyze the entropy of the data series statistics over time. Third, we use the Kullback–Leibler divergence to compare the empirical data and multidimensional scaling (MDS) techniques for data analysis and visualization. Entropy-based analysis is adopted to assess complexity, having the advantage of yielding a single parameter to express relationships between the data. The classical and the generalized (fractional) entropy and Kullback–Leibler divergence are used. The generalized measures allow a clear identification of patterns embedded in the data.
Resumo:
Electroanalytical methods based on square-wave adsorptive-stripping voltammetry (SWAdSV) and flow-injection analysis with SWAdSV detection (FIA-SWAdSV) were developed for the determination of paroxetine (PRX). The methods were based on the reduction of PRX at a mercury drop electrode at −1.55V versus Ag/AgCl, in a borate buffer of pH 8.8, and the possibility of accumulating the compound at the electrode surface. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine PRX using FIASWAdSV. This method enables analysis of up to 120 samples per hour at reduced costs. Both methods developed were validated and successfully applied to the quantification of PRX in pharmaceutical products.
Resumo:
The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH=1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1x10-6 mol L-1 and 1.2x10-8 mol L-1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (<5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods.
Resumo:
Com a massificação do uso da tecnologia no dia-a-dia, os sistemas de localização têm vindo a aumentar a sua popularidade, devido à grande diversidade de funcionalidades que proporcionam e aplicações a que se destinam. No entanto, a maior parte dos sistemas de posicionamento não funcionam adequadamente em ambientes indoor, impedindo o desenvolvimento de aplicações de localização nestes ambientes. Os acelerómetros são muito utilizados nos sistemas de localização inercial, pelas informações que fornecem acerca das acelerações sofridas por um corpo. Para tal, neste trabalho, recorrendo à análise do sinal de aceleração provindo de um acelerómetro, propõe-se uma técnica baseada na deteção de passos para que, em aplicações futuras, possa constituir-se como um recurso a utilizar para calcular a posição do utilizador dentro de um edifício. Neste sentido, este trabalho tem como objetivo contribuir para o desenvolvimento da análise e identificação do sinal de aceleração obtido num pé, por forma a determinar a duração de um passo e o número de passos dados. Para alcançar o objetivo de estudo foram analisados, com recurso ao Matlab, um conjunto de 12 dados de aceleração (para marcha normal, rápida e corrida) recolhidos por um sistema móvel (e provenientes de um acelerómetro). A partir deste estudo exploratório tornou-se possível apresentar um algoritmo baseado no método de deteção de pico e na utilização de filtros de mediana e Butterworth passa-baixo para a contagem de passos, que apresentou bons resultados. Por forma a validar as informações obtidas nesta fase, procedeu-se, seguidamente, à realização de um conjunto de testes experimentais a partir da recolha de 33 novos dados para a marcha e corrida. Identificaram-se o número de passos efetuados, o tempo médio de passo e da passada e a percentagem de erro como as variáveis em estudo. Obteve-se uma percentagem de erro igual a 1% para o total dos dados recolhidos de 20, 100, 500 e 1000 passos com a aplicação do método proposto para a contagem do passo. Não obstante as dificuldades observadas na análise dos sinais de aceleração relativos à corrida, o algoritmo proposto mostrou bom desempenho, conseguindo valores próximos aos esperados. Os resultados obtidos permitem afirmar que foi possível atingir-se o objetivo de estudo com sucesso. Sugere-se, no entanto, o desenvolvimento de futuras investigações de forma a alargar estes resultados em outras direções.
Resumo:
O estudo aqui apresentado não detém caráter exaustivo pelo fato de que novos dados poderão surgir daqui para frente, principalmente por se tratar de uma espécie de “feeling” relacionado à execução das semicolcheias do samba, que pode ser interpretado de maneiras diferentes. Trata-se de uma pesquisa empírica que se fundamentou em entrevistas juntamente do profissional responsável pela criação de Ação e Reação: o músico Brasileiro Kiko Freitas, nas suas experiências e conhecimento pessoal. Em decorrência das falas buscou-se apoio em Bardin e sua Análise de Conteúdo, base científica para a falta de bibliografia sobre o assunto específico, também manuais e métodos sobre técnicas de baquetas existentes, além da consulta em vídeo-aulas e sites online. A trajetória perseguida buscou encontrar a interface entre as respostas do entrevistado e os pressupostos teóricos de Bardin, naquilo que tem relação ao assunto-foco do estudo: Uma nova técnica de mãos com estilo, economia de movimentos e que seja uma alternativa para a execução do samba na bateria.
Resumo:
Dissertação apresentada ao Instituto Superior de Contabilidade para a obtenção do Grau deMestre em Auditoria Orientada por Alcina Augusta de Sena Portugal Dias
Resumo:
Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.
Resumo:
A detailed study of voltammetric behavior of ethiofencarb (ETF) is reported using glassy carbon electrode (GCE) and hanging mercury drop electrode (HMDE). With GCE, it is possible to verify that the oxidative mechanism is irreversible, independent of pH, and the maximum intensity current was observed at +1.20 V vs. AgCl/Ag at pH 1.9. A linear calibration line was obtained from 1.0x10-4 to 8.0x10-4 mol L-1 with SWV method. To complete the electrochemical knowledge of ETF pesticide, the reduction was also explored with HMDE. A well-defined peak was observed at –1.00V vs. AgCl/Ag in a large range of pH with higher signal at pH 7.0. Linearity was obtained in 4.2x10-6 and 9.4x10-6 mol L-1 ETF concentration range. An immediate alkaline hydrolysis of ETF was executed, producing a phenolic compound (2-ethylthiomethylphenol) (EMP), and the electrochemical activity of the product was examined. It was deduced that it is oxidized on GCE at +0.75V vs. AgCl/Ag with a maximum peak intensity current at pH 3.2, but the compound had no reduction activity on HMDE. Using the decrease of potential peak, a flow injection analysis (FIA) system was developed connected to an amperometric detector, enabling the determination of EMP over concentration range of 1.0x10-7 and 1.0x10-5 mol L-1 at a sampling rate of 60 h-1. The results provided by FIA methodology were performed by comparison with results from high-performance liquid chromatography (HPLC) technique and demonstrated good agreement with relative deviations lower than 4%. Recovery trials were performed and the obtained values were between 98 and 104%.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Professora Doutora Ana Maria Alves Bandeira e Professora Doutora Deolinda Meira