119 resultados para Playgrounds, regulations, design, infrastructures, safety
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)
Resumo:
This paper presents an investigation of design code provisions for steel-concrete composite columns. The study covers the national building codes of United States, Canada and Brazil, and the transnational EUROCODE. The study is based on experimental results of 93 axially loaded concrete-filled tubular steel columns. This includes 36 unpublished, full scale experimental results by the authors and 57 results from the literature. The error of resistance models is determined by comparing experimental results for ultimate loads with code-predicted column resistances. Regression analysis is used to describe the variation of model error with column slenderness and to describe model uncertainty. The paper shows that Canadian and European codes are able to predict mean column resistance, since resistance models of these codes present detailed formulations for concrete confinement by a steel tube. ANSI/AISC and Brazilian codes have limited allowance for concrete confinement, and become very conservative for short columns. Reliability analysis is used to evaluate the safety level of code provisions. Reliability analysis includes model error and other random problem parameters like steel and concrete strengths, and dead and live loads. Design code provisions are evaluated in terms of sufficient and uniform reliability criteria. Results show that the four design codes studied provide uniform reliability, with the Canadian code being best in achieving this goal. This is a result of a well balanced code, both in terms of load combinations and resistance model. The European code is less successful in providing uniform reliability, a consequence of the partial factors used in load combinations. The paper also shows that reliability indexes of columns designed according to European code can be as low as 2.2, which is quite below target reliability levels of EUROCODE. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
A large percentage of pile caps support only one column, and the pile caps in turn are supported by only a few piles. These are typically short and deep members with overall span-depth ratios of less than 1.5. Codes of practice do not provide uniform treatment for the design of these types of pile caps. These members have traditionally been designed as beams spanning between piles with the depth selected to avoid shear failures and the amount of longitudinal reinforcement selected to provide sufficient flexural capacity as calculated by the engineering beam theory. More recently, the strut-and-tie method has been used for the design of pile caps (disturbed or D-region) in which the load path is envisaged to be a three-dimensional truss, with compressive forces being supported by concrete compressive struts between the column and piles and tensile forces being carried by reinforcing steel located between piles. Both of these models have not provided uniform factors of safety against failure or been able to predict whether failure will occur by flexure (ductile mode) or shear (fragile mode). In this paper, an analytical model based on the strut-and-tie approach is presented. The proposed model has been calibrated using an extensive experimental database of pile caps subjected to compression and evaluated analytically for more complex loading conditions. It has been proven to be applicable across a broad range of test data and can predict the failures modes, cracking, yielding, and failure loads of four-pile caps with reasonable accuracy.
Resumo:
Safety Instrumented Systems (SIS) are designed to prevent and / or mitigate accidents, avoiding undesirable high potential risk scenarios, assuring protection of people`s health, protecting the environment and saving costs of industrial equipment. The design of these systems require formal methods for ensuring the safety requirements, but according material published in this area, has not identified a consolidated procedure to match the task. This sense, this article introduces a formal method for diagnosis and treatment of critical faults based on Bayesian network (BN) and Petri net (PN). This approach considers diagnosis and treatment for each safety instrumented function (SIF) including hazard and operability (HAZOP) study in the equipment or system under control. It also uses BN and Behavioral Petri net (BPN) for diagnoses and decision-making and the PN for the synthesis, modeling and control to be implemented by Safety Programmable Logic Controller (PLC). An application example considering the diagnosis and treatment of critical faults is presented and illustrates the methodology proposed.
Resumo:
Objective: To evaluate the efficacy of diethylpropion on a long-term basis, with emphasis in cardiovascular and psychiatric safety aspects. Design: Randomized, double-blind, placebo-controlled trial Measurements: Following a 2-week screening period, 69 obese healthy adults received a hypocaloric diet and were randomized to diethylpropion 50 mg BID (n = 37) or placebo (n = 32) for 6 months. After this period, all participants received diethylpropion in an open-label extension for an additional 6 months. The primary outcome was percentage change in body weight. Electrocardiogram (ECG), echocardiography and clinical chemistry were performed at baseline and every 6 months. Psychiatric evaluation and application of Hamilton rating scales for depression and anxiety were also performed by experienced psychiatrists at baseline and every 3 months. Results: After 6 months, the diethylpropion group lost an average of 9.8% (s.d. 6.9%) of initial body weight vs 3.2% (3.7%) in the placebo group (P < 0.0001). From baseline to month 12, the mean weight loss produced by diethylpropion was 10.6% (8.3%). Participants in the placebo group who were switched to diethylpropion after 6 months lost an average of 7.0% (7.7%) of initial body weight. The difference between groups at month 12 was not significant (P = 0.07). No differences in blood pressure, pulse rate, ECG and psychiatric evaluation were observed. Dry mouth and insomnia were the most frequent adverse events. Conclusion: Diethylpropion plus diet produced sustained and clinically significant weight loss over 1 year. It seems to be safe in relation to cardiovascular and psychiatric aspects in a well-selected population. International Journal of Obesity (2009) 33, 857-865; doi: 10.1038/ijo.2009.124; published online 30 June 2009
Resumo:
Background: Despite significant advancements in psychopharmacology, treating major depressive disorder (MDD) is still a challenge considering the efficacy, tolerability, safety, and economical costs of most antidepressant drugs. One approach that has been increasingly investigated is modulation of cortical activity with tools of non-invasive brain stimulation - such as transcranial magnetic stimulation and transcranial direct current stimulation (tDCS). Due to its profile, tDCS seems to be a safe and affordable approach. Methods and design: The SELECT TDCS trial aims to compare sertraline vs. tDCS in a double-blinded, randomized, factorial trial enrolling 120 participants to be allocated to four groups to receive sertraline + tDCS, sertraline, tDCS or placebo. Eligibility criteria are moderate-to-severe unipolar depression (Hamilton Depression Rating Scale >17) not currently on sertraline treatment. Treatment will last 6 weeks and the primary outcome is depression change in the Montgomery-Asberg Depression Rating Score (MADRS). Potential biological markers that mediate response, such as BDNF serum levels, Val66Met BDNF polymorphism, and heart rate variability will also be examined. A neuropsychological battery with a focus on executive functioning will be administered. Discussion: With this design we will be able to investigate whether tDCS is more effective than placebo in a sample of patients free of antidepressants and in addition, we will be able to secondarily compare the effect sizes of sertraline vs. tDCS and also the comparison between tDCS and combination of tDCS and sertraline. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background The protease-activated receptor 1 (PAR-1), the main platelet receptor for thrombin, represents a novel target for treatment of arterial thrombosis, and SCH 530348 is an orally active, selective, competitive PAR-1 antagonist. We designed TRA.CER to evaluate the efficacy and safety of SCH 530348 compared with placebo in addition to standard of care in patients with non-ST-segment elevation (NSTE) acute coronary syndromes (ACS) and high-risk features. Trial design TRA.CER is a prospective, randomized, double-blind, multicenter, phase III trial with an original estimated sample size of 10,000 subjects. Our primary objective is to demonstrate that SCH 530348 in addition to standard of care will reduce the incidence of the composite of cardiovascular death, myocardial infarction (MI), stroke, recurrent ischemia with rehospitalization, and urgent coronary revascularization compared with standard of care alone. Our key secondary objective is to determine whether SCH 530348 will reduce the composite of cardiovascular death, MI, or stroke compared with standard of care alone. Secondary objectives related to safety are the composite of moderate and severe GUSTO bleeding and clinically significant TIMI bleeding. The trial will continue until a predetermined minimum number of centrally adjudicated primary and key secondary end point events have occurred and all subjects have participated in the study for at least I year. The TRA.CER trial is part of the large phase III SCH 530348 development program that includes a concomitant evaluation in secondary prevention. Conclusion TRA.CER will define efficacy and safety of the novel platelet PAR-1 inhibitor SCH 530348 in the treatment of high-risk patients with NSTE ACS in the setting of current treatment strategies. (Am Heart J 2009; 158:327-34.)
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background: The effects of etonogestrel (ETG)-releasing contraceptive implant during the immediate postpartum period on maternal safety are unknown. Study design: Forty healthy women exclusively breastfeeding were randomized to receive either ETG-releasing implant 24-48 h after delivery (n=20) or depot medroxyprogesterone acetate (DMPA group; n=20) at the sixth week postpartum. We measured blood pressure, maternal and neonatal weight, body mass index (BMI; kg/m(2)), waist circumference (WC), complete blood count, C-reactive protein, interleukin-6, tumor necrosis factor (TNF-alpha), lipid profile, fasting serum glucose and maintenance of exclusive lactation up to the 12th week postpartum. Results: Decreases in mean maternal weight, BMI (kg/m(2)) and WC were significantly greater in the ETG-releasing implant group than in the MPA group during the first 6 weeks postpartum (-4.64 +/- 2.71 kg vs. -2.6 +/- 2.45 kg mean +/- SD, p=.017; -1.77 +/- 1.06 kg/m(2) vs. -0.97 +/- 0.95 kg/m(2), p=.026; -15.3 +/- 6.72 cm vs. -9.05 +/- 5.84 cm, p=.003, respectively). In addition, total cholesterol and HDL, were lower in DMPA users, and TNF-alpha and leukocytes were higher in DMPA users compared to in the implant group, between 6 and 12 weeks after delivery. The newborns of implant users showed a trend towards gaining more weight, as compared with the infants of the DMPA mothers during the first 6 weeks of life (implant group: +1460.50 +/- 621.34 g vs. DMPA group: +1035.0 +/- 562.43 g, p=.05). The remaining variables, including the duration of exclusive breastfeeding, were similar between the groups. Conclusion: The insertion of ETG-releasing contraceptive implant during the immediate postpartum period was not associated with deleterious maternal clinical effects or with significant maternal metabolic alterations or decreased infant weight gain. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Traditional venom immunotherapy uses injections of whole bee venom in buffer or adsorbed in Al (OH)(3) in an expensive, time-consuming way. New strategies to improve the safety and efficacy of this treatment with a reduction of injections would, therefore, be of general interest. It would improve patient compliance and provide socio-economic benefits. Liposomes have a long tradition in drug delivery because they increase the therapeutic index and avoid drug degradation and secondary effects. However, bee venom melittin (Mel) and phospholipase (PLA(2)) destroy the phospholipid membranes. Our central idea was to inhibit the PLA(2) and Mel activities through histidine alkylation and or tryptophan oxidation (with pbb, para-bromo-phenacyl bromide, and/or NBSN-bromosuccinimide, respectively) to make their encapsulations possible within stabilized liposomes. We strongly believe that this formulation will be nontoxic but immunogenic. In this paper, we present the whole bee venom conformation characterization during and after chemical modification and after interaction with liposome by ultraviolet, circular dichroism, and fluorescence spectroscopies. The PLA(2) and Mel activities were, measured indirectly by changes in turbidity at 400(nm), rhodamine leak-out, and hemolysis. The native whole bee venom (BV) presented 78.06% of alpha-helical content. The alkylation (A-BV) and succynilation (S-BV) of BV increased 0.44 and 0.20% of its alpha-helical content. The double-modified venom (S-A-BV) had a 0.74% increase of alpha-helical content. The BV chemical modification induced another change on protein conformations observed by Trp that became buried with respect to the native whole BV. It was demonstrated that the liposomal membranes must contain pbb (SPC:Cho:pbb, 26:7:1) as a component to protect them from aggregation and/or fusion. The membranes containing pbb maintained the same turbidity (100%) after incubation with modified venom, in contrast with pbb-free membranes that showed a 15% size decrease. This size decrease was interpreted as membrane degradation and was corroborated by a 50% rhodamine leak-out. Another fact that confirmed our interpretation was the observed 100% inhibition of the hemolytic activity after venom modification with pbb and NBS (S-A-BV). When S-A-BV interacted with liposomes, other protein conformational changes were observed and characterized by the increase of 1.93% on S-A-BV alpha-helical content and the presence of tryptophan residues in a more hydrophobic environment. In other words, the S-A-BV interacted with liposomal membranes, but this interaction was not effective to cause aggregation, leak-out, or fusion. A stable formulation composed by S-A-BV encapsulated within liposomes composed by SPC:Cho:pbb, at a ratio of 26:7:1, was devised. Large unilamellar vesicles of 202.5 nm with a negative surface charge (-24.29 mV) encapsulated 95% of S-A-BV. This formulation can, now, be assayed on VIT.
Resumo:
For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30) had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05). When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group). The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning.
Resumo:
Current scientific knowledge provides clear evidence that alcohol-based mouthwashes can be beneficial in a daily oral health routine, including dental hygiene and plaque control. Several issues are worth discussing, in spite of the wealth of supporting evidence. Despite some undesirable effects to some people, like burning sensation, and some contraindications, like the use by infants, alcohol addicts and patients with mucosal injuries, there is no reason to avoid the use of alcohol-containing mouthwashes as long as they are used following proper guidance by dental professionals and the manufacturers' instructions. The alleged correlation between oral cancer and alcohol-based mouthrinses presents so little, weak, inconsistent and even contradictory evidence in the literature that any kind of risk warning to patients would be uncalled for. Antimicrobial mouthrinses are safe and effective in reducing plaque and gingivitis, and should be part of a comprehensive oral health care regimen that includes brushing, flossing and rinsing to prevent or minimize periodontal disease.
Resumo:
This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.
Resumo:
This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.
Resumo:
OBJETIVO: Avaliar a fidedignidade das informações sobre dados nutricionais declarados em rótulos de alimentos comercializados. MÉTODOS: Foram avaliados 153 alimentos industrializados habitualmente consumidos por crianças e adolescentes, comercializados no município de São Paulo (SP) entre os anos de 2001 e 2005. Os teores de nutrientes informados pelos rótulos foram confrontados com os resultados obtidos por métodos analíticos (físico-químicos) oficiais, considerando a variabilidade de 20% tolerada pela legislação vigente, para aprovar ou condenar as amostras. Foram calculadas médias, desvios-padrão e intervalos com 95% de confiança para os nutrientes analisados, assim como a distribuição da freqüência percentual de amostras condenadas. RESULTADOS: Todos os produtos salgados analisados apresentaram inconformidades relativamente ao conteúdo de fibra alimentar, sódio ou de gorduras saturadas. Os produtos doces apresentaram variação de zero a 36% de condenação relativamente ao teor de fibra alimentar. Mais da metade (52%) dos biscoitos recheados foram condenados quanto à quantidade de gorduras saturadas. Os nutrientes implicados com a obesidade e suas complicações para a saúde foram aqueles que apresentaram maiores proporções de inconformidade. A falta de fidedignidade das informações de rótulos nas amostras analisadas viola as disposições da Resolução da Diretoria Colegiada 360/03 da ANVISA e os direitos garantidos pela lei de Segurança Alimentar e Nutricional e pelo Código de Defesa do Consumidor. CONCLUSÕES: Foram encontrados altos índices de não conformidade dos dados nutricionais nos rótulos de alimentos destinados ao público adolescente e infantil, indicando a urgência de ações de fiscalização e de outras medidas de rotulagem nutricional