328 resultados para Domingos Caldas Barbosa

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palladium plus magnesium nitrates with and without Ir, Ru and W were evaluated for the simultaneous determination of As, Cu and Pb in cachaca by graphite furnace atomic absorption spectrometry. For 20 mu L sample, 5 mu L Pd(NO(3))(2) and 3 mu L Mg(NO(3))(2) dispensed together onto the Ir-coated platform of the THGA, analytical curves in the 0-30.0 mu g L(-1) As, 0-1.50 mg L(-1) Cu and 0-60.0 mu g L(-1) Pb were built up and typical linear correlation coefficients were always better than 0.999. The limit of detection was 1.30 mu g L(-1) As, 140 mu g L(-1) Cu and 0.90 mu g L(-1) Pb. As, Cu and Pb contents in 10 cachaca samples agreed with those obtained by ICP-MS. Recoveries of spiked samples varied from 96% to 106% (As), 97% to 112% (Cu) and 92% to 108% (Pb). The relative standard deviation (n = 12) was typically 2.7%, 3.3% and 1.9%. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carotid artery stenosis due to arteriosclerosis increases the risk of cerebral ischemia via embolic phenomena or reduced blood flow. The changes in cerebral perfusion that may occur after treatment are not clearly understood. This study evaluated the changes in cerebral microcirculation following carotid angioplasty with stenting (CAS) under cerebral protection with filters using ultrafast gradient echo (GRE) perfusion weighted imaging (PWI) with magnetic resonance imaging (MRI). Prospectively, 21 cervical carotid stenosis patients, mean age 69.95 years, underwent MRI 12 h before and 72 h after CAS. PWI parameters were collected for statistical analysis: cerebral blood volume (CB V), mean transit time (MTT) and time to peak (TTP). Statistical analysis was applied to absolute parameters and to values normalized against those from the contralateral parenchyma. The main finding of this study was improved hemodynamics for the normalized data after CAS, shown by reduced MTT (p<0.001) and TTP (p=0.019) in the territory fed by the middle cerebral artery ipsilateral to the CAS. Absolute data showed increased blood volume in the cerebral hemispheres after CAS, which was more accentuated on the stent side (p=0.016) than the contralateral side (p=0.029). Early improvements in cerebral perfusion, mainly seen in the normalized data, were clearly demonstrated in the timing parameters - TTP & MTT - after CAS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Termo do 1º Consenso em Disfunção Temporomandibular e Dor Orofacial* foi criado com o propósito de substituir divergências por evidência científica dentro dessa especialidade da Odontologia. O documento oferece informações claras e fundamentadas para orientar o cirurgião-dentista e demais profissionais de saúde sobre os cuidados demandados pelo paciente, tanto no processo de diagnóstico diferencial quanto na fase de aplicação das terapias de controle da dor e disfunção. O Termo foi aprovado no mês de janeiro de 2010 em reunião realizada durante o Congresso Internacional de Odontologia do Estado de São Paulo e converge o pensamento dos profissionais mais conceituados do Brasil na especialidade Disfunção Temporomandibular e Dor Orofacial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: investigar o conhecimento dos professores de 1ª a 4ª série quanto ao distúrbio da leitura e escrita, pesquisando quais dificuldades referentes a esse distúrbio, foram apresentadas por estes professores. MÉTODOS: esses dados foram obtidos, por meio de um questionário informativo de 10 questões, aplicados a 50 professores de 1ª a 4ª série, da cidade de Bauru. Os questionários foram analisados e tabulados, e receberam tratamento estatístico pertinente. RESULTADOS: os resultados obtidos revelaram que os professores possuem um conhecimento superficial a respeito do distúrbio da leitura e escrita, sendo que muitos adquiriram tal conhecimento fora do ambiente de graduação. Verificou-se também que os professores apesar de encaminharem seus alunos ao fonoaudiólogo, possuem visão limitada quanto à atuação deste profissional. O distúrbio da leitura e escrita foi considerado como um problema próprio da criança, sendo pouco reconhecido como uma falha que também pode ser da escola ou da metodologia de ensino. CONCLUSÃO: os professores logram um saber pouco fundamentado a respeito do distúrbio da leitura e escrita; sendo que, as dificuldades giraram em torno: da identificação real do problema; de quais manifestações caracterizam esse problema; e de como intervir e prevenir.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prosthetic rehabilitation of an atrophic mandible is usually unsatisfactory due to the lack of support tissues, mainly bone and keratinized mucosa for treatment with osseointegrated implants or even conventional prosthesis. The prosthetic instability leads to social and functional limitations and chronic physical trauma decreasing the patient's quality of life. A 53-year-old female patient sought care at our surgical service complaining of impairment of her masticatory function associated with the instability of the lower total prosthetic denture. The clinical and complementary exams revealed edentulism in both arches, while the mandibular arch presented severe reabsorption resulting in denture instability and chronic trauma to the oral mucosa. The proposed treatment plan consisted in the mandibular rehabilitation with osseointegrated implants and fixed Brånemark's protocol prosthesis after mandibular reconstruction applying the modified visor osteotomy technique. The proposed technique offered predictable results for reconstruction of the severely resorbed edentulous mandible and posterior rehabilitation with osseointegrated implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD. MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level. RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI. CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss (%). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71% ± 11.36) and G2 (24.01% ± 3.33) (p=0.000) and between G1 (50.71% ± 11.36) and G3 (25.60% ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100%) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37%) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. MATERIAL AND METHODS: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). RESULTS: High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - ΔE=2.05; XL 3000 - ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. CONCLUSION: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to test the hypothesis that both human and bovine sclerotic dentin have similar hardness properties, in addition to similar micromorphological characteristics. Sixteen teeth (8 human and 8 bovine) exhibiting exposed dentin in the incisal edge and showing characteristics typical of sclerosis were used. Vickers surface microhardness testing was conducted. Three areas of the dentin surface of each specimen were selected. All teeth were processed for scanning electron microscopy in order to estimate the amount (in percentage) of solid dentin on the sclerotic dentin surface. The data were compared by Student's t test (α = 0.05). The micromorphological and microhardness data were compared by Pearson's linear correlation test (α = 0.05). The mean percentages of solid dentin of human and bovine sclerotic dentin were similar (human 90.71 ± 0.83 and bovine 89.08 ± 0.81, p = 0.18). The mean microhardness value (VHN) of human sclerotic dentin was significantly higher than that of bovine sclerotic dentin (human 45.26 ± 2.92 and bovine 29.93 ± 3.83, p = 0.006). No correlation was found between the microhardness values and the amount of solid dentin in the sclerotic dentin, irrespective of the species considered (human R² = 0.0240, p = 0.714; bovine R² = 0.0017, p = 0.923; and combined R² = 0.038, p = 0.46). We concluded that although both bovine and human sclerotic dentin present a similar amount of solid tissue, human sclerotic dentin presents higher microhardness than bovine sclerotic dentin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate different protocols to isolate stem cells from ovine umbilical cord blood and adipose tissue. METHODS: There were used 5 samples of umbilical blood and 5 samples of perirenal adipose tissue from 10 female sheep. All the samples were obtained through surgery, to harvest aseptic samples. There were used 3 protocols for obtainment and culture of umbilical cord blood stem cells and 4 protocols for ovine adipose tissue stem cells. RESULTS: It was possible to observe only one successful protocol for the obtainment of umbilical cord blood stem cells. When analyzing the techniques used to obtain adipose tissue stem cells, only one of the methods was effective as well. Through colony forming unit assay, there were obtained 58 colonies of cells after seven days in culture. Flow citometry tests revealed the cells were positive to CD44 and exhibited negative reaction to CD38, CD45, CD41/61. These cells showed a growth curve with very well defined phases LOG, LAG and PLATEAU. This phases are typically seem in mesenchymal stem cells growth curves. CONCLUSIONS: The isolation and culture of mesenchymal stem cells from ovine umbilical cord blood are complex and request more detailed assays. Stem cells from fat tissue sheep showed mesenchymal characteristics, according to their cell growth curve, ability to origin colonies of fibroblastoid cells and positive reactivity with the antibody CD44 by flow citometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to study the effect of the hydrolysis degree (HD) and the concentration (C PVA) of two types of poly (vinyl alcohol) (PVA) and the effect of the type and the concentration of plasticizers on the phase properties of biodegradable films based on blends of gelatin and PVA, using a response-surface methodology. The films were made by casting and the studied properties were their glass (Tg) and melting (Tm) transition temperatures, which were determined by diferential scanning calorimetry (DSC). For the data obtained on the first scan, the fitting of the linear model was statistically significant and predictive only for the second melting temperature. In this case, the most important effect on the second Tm of the first scan was due to the HD of the PVA. In relation to the second scan, the linear model could be fit to Tg data with only two statistically significant parameters. Both the PVA and plasticizer concentrations had an important effect on Tg. Concerning the second Tm of the second scan, the linear model was fit to data with two statistically significant parameters, namely the HD and the plasticizer concentration. But, the most important effect was provoked by the HD of the PVA.