Correlation between metal-ceramic bond strength and coefficient of linear thermal expansion difference


Autoria(s): LOPES, Stella Crosara; PAGNANO, Valéria Oliveira; ROLLO, João Manuel Domingos de Almeida; LEAL, Mônica Barbosa; BEZZON, Osvaldo Luiz
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

26/03/2012

26/03/2012

2009

Resumo

The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.

FAPESP

Identificador

Journal of Applied Oral Science, v.17, n.2, p.122-128, 2009

1678-7757

http://producao.usp.br/handle/BDPI/11078

10.1590/S1678-77572009000200010

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572009000200010

http://www.scielo.br/pdf/jaos/v17n2/09.pdf

Idioma(s)

eng

Publicador

Faculdade De Odontologia De Bauru - USP

Relação

Journal of Applied Oral Science

Direitos

openAccess

Copyright Faculdade De Odontologia De Bauru - USP

Palavras-Chave #Metal-ceramic #Bond strength #Ni-Cr alloy #Pd-Ag alloy #Dilatometric test
Tipo

article

original article

publishedVersion