99 resultados para Drug testing
Resumo:
This study reports on the views of Primary Health Care (PHC) providers in Southeast Brazil on the use of alcohol and other drugs which reflect stigma, moralization, or negative judgment. Six hundred nine PHC professionals from the Brazilian states of Sao Paulo and Minas Gerais took part in the study. The majority (86.5%) of these professionals were female. Attitudes toward the use of alcohol and other drugs were evaluated in comparison to Hansen`s disease, obesity, depression, schizophrenia. HIV/AIDS, and tobacco use. The use of tobacco, marijuana/cocaine, and alcohol were the most negatively judged behaviors (p < 0.05). Nursing assistants and community health care workers demonstrated the severest judgment of alcohol use. In addition, marijuana/cocaine addicts and alcoholics suffered the highest rate of rejection by professionals. The hypothesis that the use of alcohol and other drugs is a behavior stigmatized by health professionals being confirmed, it is important to develop strategies for changing provider attitudes in order to provide a higher quality of service to these patients. This study is important as a first study among PHC professionals about social stigma of alcohol and other drugs users. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Objective To compare the demographic features, presenting manifestations, diagnostic investigations, disease course, and drug therapies of children with juvenile dermatomyositis (JDM) followed in Europe and Latin America. Methods Patients were inception cohorts seen between 1980 and 2004 in 27 paediatric rheumatology centres. The following information was collected through the review of patient charts: sex; age at disease onset; date of disease onset and diagnosis; onset type; presenting clinical features; diagnostic investigations; course type; and medications received during disease course. Results Four hundred and ninety patients (65.5% females, mean onset age 7.0 years, mean disease duration 7.7 years) were included. Disease presentation was acute or insidious in 57.1% and 42.9% of the patients, respectively. The course type was monophasic in 41.3% of patients and chronic polycyclic or continuous in 58.6% of patients. The more common presenting manifestations were muscle weakness (84.9%), Gottron`s papules (72.9%), heliotrope rash (62%), and malar rash (56.7%). Overall, the demographic and clinical features of the 2 continental cohorts were comparable. European patients received more frequently high-dose intravenous methylprednisolone, cyclosporine, cyclophosphamide, and azathioprine, while methotrexate and antimalarials medications were used more commonly by Latin American physicians. Conclusion The demographic and clinical characteristics of JDM are similar in European and Latin American patients. We found, however, several differences in the use of medications between European and Latin American paediatric rheumatologists.
Resumo:
Epilepsy is the most common neurological disorder in both dogs and humans. Although the pharmacological options for treatment of epilepsies have increased. it has been reported that two-thirds of dogs with epilepsy are refractory to antiepileptic drug therapy. To our knowledge, there are no experimental Studies in the literature that show an effect of omega-3 supplementation oil epilepsy in dogs. Our case study describes the effectiveness of daily intake of a moderate amount of fish oil in a case of canine epilepsy. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Ivermectin (IVM) is an antiparasitic drug, widely used in domestic animals. In mammals, IVM act as a GABA agonist. This neurotransmitter has an important role in the regulation of sexual behavior. Thus, this study sought to investigate the effects of various medically relevant doses IVM on the sexual behavior of male rats. In particular, we also wished to examine if previous sexual experience modulated responses to IVM. In the first experiment, the sexual behavior of inexperienced male rats was analyzed after they received 0.2, 0.6, 1.0 or 2.0 mg/kg IVM, 15 mm prior to behavioral testing. In the second experiment, the effects of four previous sexual experiences on IVM treated rats (1.0 or 2.0 mg/kg, 15 min prior to the 5th session) were assessed. The standard therapeutic dose (0.2 mg/kg) did not impair the sexual behavior of inexperienced male rats. At a more concentrated dose (0.6 mg/kg), which is still within the therapeutic range, the appetitive phase of sexual behavior of inexperienced male rats was impaired. Likewise, 1.0 mg/kg impaired the appetitive phase. Previous sexual experience blocked almost entirely this sexual impairment, suggesting that previous sexual experience exerts a positive effect in attenuating the sexual impairment produced by IVM treatment. Therefore, the standard therapeutic dose of IVM can be used without producing side effects on sexual behavior. Use of more concentrated therapeutic doses is not recommended during reproductive periods, unless the animals have had previous sexual experience. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This work provides experimental phase diagram of mitotane, a drug used in the chemotherapy treatment of adrenocortical carcinoma, in compressed and/or supercritical CO(2). The synthetic-static method in a high-pressure variable-volume view cell coupled with a transmitted-light intensity probe was used to measure the solid-fluid (SF) equilibrium data. The phase equilibrium experiments were determined in temperature ranging from (298.2 to 333.1) K and pressure up to 22 MPa. Peng-Robinson equation of state (PR-EoS) with classical mixing rule was used to correlate the experimental data. Excellent agreement was found between experimental and calculated values. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Our objective was to compare the polymerization stress (sigma(pol)) of a series of composites obtained using poly(methyl methacrylate) (PMMA) or glass as bonding substrates, and to compare the results with those from in vitro microleakage of composite restorations. The tested hypothesis was that stress values obtained in a less rigid testing system (i.e. using PMMA) would show a better relationship with microleakage data. Five dental composites were tested: Filtek Z250 (FZ), Z100 (Z1), Concept (CO), Durafill (DU) and Heliomolar (HM). sigma(pol) was determined in 1 mm high specimens inserted between two rods (empty set = 5 mm) of either PMMA or glass. The composite elastic modulus (E) was obtained by three-point bending. sigma(pol) and E data were submitted to a one-way analysis of variance/Tukey test (alpha = 0.05). For the microleakage test (MI), bovine incisors received cylindrical cavities (empty set = 5 mm, h = 2 mm), which were restored in bulk. After storage for 24 h in water, specimens were subjected to dye penetration using AgNO(3) as tracer. Specimens were sectioned twice, perpendicularly, and microleakage was measured (in millimeters) under 20x magnification. Data from MI were submitted to the Kruskal-Wallis test. Means (SD) of sigma(pol) (MPa) using glass/PMMA were FZ: 7.5(1.8)(A)/2.5(0.2)(bc); Z1: 7.3(0.5)(A)/2.8(0.3)(ab); CO: 6.8(1.1)(A)/3.2(0.5)(a); DU: 4.5(0.7)(B)/2.0(0.2)(bc); HM: 3.5(0.2)(B)/2.3(0.3)(c). sigma(pol) obtained using PMMA rods were 34-67% lower than with glass. Means (SD) for tooth average/tooth maximum microleakage were FZ: 0.92(0.19)(B)/1.53(0.30)(a); Z1: 1.19(0.21)(A)/1.75(0.20)(a); CO: 1.26(0.25)(A)/1.78(0.24)(a); DU: 0.83(0.30)(B)/1.68(0.46)(a): HM: 0.81(0.27)(B)/1.64(0.54)(a). The tested hypothesis was confirmed, as the composites showed the same ordering both in the polymerization stress test using PMMA rods and in the microleakage test. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.