122 resultados para Basaline impedance


Relevância:

10.00% 10.00%

Publicador:

Resumo:

One major challenge for the widespread application of direct methanol fuel cells (DMFCs) is to decrease the amount of platinum used in the electrodes, which has motivated a search for novel electrodes containing platinum nanoparticles. In this study, platinum nanoparticles were electrodeposited on layer-by-layer (LbL) films from TiO(2) and poly(vinyl sulfonic) (PVS), by immersing the films into a H(2)PtCl(6) solution and applying a 100 mu A current during different electrode position times. Scanning tunnel microscopy (STM) and atomic force microscopy (AFM) images showed increased platinum particle size and electrode roughness for increasing electrodeposition times. The potentiodynamic profile of the electrodes indicated that oxygen-like species in 0.5 mol L(-1) H(2)SO(4) were formed at less positive potentials for the smallest platinum particles. Electrochemical impedance spectroscopy measurements confirmed the high reactivity for the water dissociation and the large amount of oxygen-like species adsorbed on the smallest platinum nanoparticles. This high oxophilicity of the smallest nanoparticles was responsible for the electrocatalytic activity of Pt-TiO(2)/PVS systems for methanol electrooxidation, according to the Langmuir-Hinshelwood bifunctional mechanism. Significantly, the approach used here combining platinum electrodeposition and LbL matrices allows one to both control the particle size and optimize methanol electrooxidation, being therefore promising for producing membrane-electrode assemblies of DMFCs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The image reconstruction using the EIT (Electrical Impedance Tomography) technique is a nonlinear and ill-posed inverse problem which demands a powerful direct or iterative method. A typical approach for solving the problem is to minimize an error functional using an iterative method. In this case, an initial solution close enough to the global minimum is mandatory to ensure the convergence to the correct minimum in an appropriate time interval. The aim of this paper is to present a new, simple and low cost technique (quadrant-searching) to reduce the search space and consequently to obtain an initial solution of the inverse problem of EIT. This technique calculates the error functional for four different contrast distributions placing a large prospective inclusion in the four quadrants of the domain. Comparing the four values of the error functional it is possible to get conclusions about the internal electric contrast. For this purpose, initially we performed tests to assess the accuracy of the BEM (Boundary Element Method) when applied to the direct problem of the EIT and to verify the behavior of error functional surface in the search space. Finally, numerical tests have been performed to verify the new technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary interstitial emphysema is a common complication of mechanical ventilation in preterm babies. We report a case of severe unilateral pulmonary interstitial emphysema in a premature newborn, treated with high-frequency oscillatory ventilation, lateral decubitus positioning and selective intubation. After complete radiological resolution of the pulmonary emphysema in the left lung, the patient was studied by electrical impedance tomography and a marked reduction of ventilation was identified in the left lung despite radiological resolution of the cysts. This finding indicates that functional abnormalities may persist for longer periods after radiologic resolution of such lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selection of the optimal positive end-expiratory pressure (PEEP) to avoid ventilator-induced lung injury in patients under mechanical ventilation is still a matter of debate. Many methods are available, but none is considered the gold standard. In the previous issue of Critical Care, Zhao and colleagues applied a method based on electrical impedance tomography to help select the PEEP that minimized ventilation inhomogeneities. Though promising when alveolar collapse and overdistension are present, this method might be misleading in patients with normal lungs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of review The nutritional assessment of children in the pediatric ICU is unique in view of the metabolic changes of the underlying disease. This review addresses the use and limitations of anthropometry and laboratorial and body composition markers in the diagnosis of the nutritional status of such patients. Recent findings The presence of inflammatory activity leads to body composition changes (lean mass reduction) and undernutrition. Nutritional assessment in pediatric ICU must prioritize anthropometric and laboratory markers that can differentiate body composition to detect specific macronutrient and micronutrient deficiencies and assessment of the inflammatory activity. Summary Nutritional assessment is one of the main aspects of the pediatric intensive care patient and is the most important tool to avoid hospital undernutrition. There is currently no gold standard for nutritional assessment in the pediatric ICU. The results of anthropometric and laboratory markers must be jointly analyzed, but individually interpreted according to disease and metabolic changes, in order to reach a correct diagnosis of the nutritional status and to plan and monitor the nutritional treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Questions about reliability of bioimpedance analysis (BIA) in morbidly obese subjects have curtailed its use in this setting, but metabolic implications might reignite the debate. In a prospective study, it was aimed to analyze anthropometric and clinical associations. Methods: Bariatric candidates (n = 94) with or without metabolic syndrome were consecutively investigated. Age was 34.9 +/- 10.4 years (68.1% females), and BMI was 40.8 +/- 4.6 kg m(-2). Methods included single-frequency BIA, anthropometrics, inflammatory indices, and general biochemical profile. Results: Body composition results (water, fat) in females, but not in males, were entirely consistent with the literature. In both genders good association was observed with anthropometrics (BMI, waist circumference), inflammatory indices (ferritin, C-reactive protein) and general biochemical variables. Anthropometric measurements also displayed comparable associations. Multivariate tests including the two sets of measurements indicated no predominance of one method over the other, one complementing the other as metabolic marker. Conclusions: BIA limitations were mostly relevant for males, not females. Despite such discrepancies, good associations with anthropometry were demonstrated for both genders. Correlations with liver enzymes, and indices of protein, carbohydrate, and lipid metabolism could be demonstrated. BIA deserves more investigations concerning liver steatosis and ongoing inflammation, and it could contribute as well, synergistically with anthropometry, to monitor weight loss, body fat shifts, and metabolic risk. Am. J. Hum. Biol. 23: 420-422, 2011. (c) 2011 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Parenteral nutrition (PN) is used to control the nutritional state after severe intestinal resections. Whenever possible, enteral nutrition (EN) is used to promote intestinal rehabilitation and reduce PN dependency. Our aim is to verify whether EN + oral intake (01) in severe short bowel syndrome (SBS) surgical adult patients can maintain adequate nutritional status in the long term. Methods: This longitudinal retrospective study included 10 patients followed for 7 post-operative years. Body mass index (BMI), percentage of involuntary loss of usual body weight (UWL), free fat mass (FFM), and fat mass (FM) composition assessed by bioelectric impedance, and laboratory tests were evaluated at 6, 12, 24, 36, 48, 60, 72, and 84 months after surgery. Energy and protein offered in HPN and at long term by HEN+ oral intake (01), was evaluated at the same periods. The statistical model of generalized estimating equations with p <0,05 was used. Results: With long term EN + 01 there was a progressive increase in the UWL, a decrease in BMI, FFM, and FM (p < 0,05). PN weaning was possible in eight patients. Infection due to central venous catheter (CVC) contamination was the most common complication (1.2 episodes CVC/patient/year). There was an increase in energy and protein intake supply provided by HEN+OI (p <0.05). All patients survived for at least 2 years, seven for 5 years and six for 7 years of follow-up. Conclusions: In the long term SBS surgical adult patients fed with HEN+OI couldn`t maintain adequate nutritional status with loss of FM and FFM. (Nutr Hosp. 2011;26:834-842) DOI:10.3305/nh.2011.26.4.5153

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & aims: Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Methods: Severely obese subjects (83 female/36 mate, mean age = 41.6 +/- 11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman`s graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. Results: BF estimations from BIA (64.8 +/- 15 kg) and ADP (65.6 +/- 16.4 kg) did not differ (p > 0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide Limit of agreement (- 10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p < 0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Conclusions: Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion. The study shows that there are differences in the measurement of the action potentials with and without the stylet in the Nucleus Freedom Contour Advance that are higher in the apex than in the base of the cochlea. Objectives. To determine if there are differences in the intraoperative impedances and in the neural response telemetry threshold values in the Nucleus Freedom Contour Advance before and after stylet removal. Subjects and methods. This was a prospective clinical study. Intraoperative impedances and neural response telemetry in users of the Freedom Contour Advance Cochlear Implant were measured before and after stylet removal. Results. There was a significant reduction in the impedance values of an average 1.5 k Omega +/- 2.3 in common ground mode and 1.3 k Omega +/- 2.3 for all monopolar modes after the stylet removal (p < 0.001). When analyzing the apical, medium, and basal electrodes, there was a statistically significant reduction in the neural response thresholds after stylet removal only in the apical electrodes (p = 0.001).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Design: Prospective, randomized, and controlled experimental study. Setting: University research laboratory. Subjects: Wistar rats were randomly assigned to control (C) [saline (0.1 ml), intraperitoneally] and ALI [paraquat (15 mg/kg), intra peritoneally] groups. Measurements and Main Results: After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H(2)O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (Delta P2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and Delta P2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. Conclusions: In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and Delta P2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful. (Crit Care Med 2009; 37:1011-1017)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We correlated dietary profile and markers of visceral and somatic obesities in nonalcoholic fatty liver disease. Methods: Patients with histologically proven fatty infiltration of the liver (n = 25, 52 +/- 11 y of age, 64% women) underwent abdominal computed tomography, bioelectrical impedance, and anthropometric measurements. Insulin resistance was evaluated (homeostasis model assessment) and dietary intake of macronutrients was estimated by 24-h recall. Main outcome measurements were correlation of carbohydrate and fat ingestion with liver histology. Results: Metabolic syndrome was present in 72% of the population, and increased waist circumference and low high-density lipoprotein cholesterol occurred in 66%. Total body fat (bioimpedance) and dietary intake of lipids were higher in patients with non-alcoholic steatohepatitis (P < 0.05), but not in diabetic subjects who exhibited more steatosis than non-alcoholic steatohepatitis. Waist circumference exhibited a good correlation with homeostasis model assessment, total energy intake, and ingestion of specific fatty acids. Body mass index correlated well with somatic and visceral adiposities. Conclusion: Energy intake and visceral adiposity were predisposing factors for fatty liver disease. Lipid input correlated with non-alcoholic steatohepatitis in the entire group and after stratification for diabetes. These findings suggest that lipid intake may play a greater role in non-alcoholic steatohepatitis than hitherto suspected. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We studied the results of chronic oral administration of amiodarone on in vitro lung tissue mechanics, light and electron microscopy. Fifteen Wistar male rats were divided into three groups. In control (CTRL) group animals received saline (0.5 mL/day). In amiodarone (AMIO) groups, amiodarone was administered by gavage at a dose of 175 mg/kg 5 days per week for 6 (6AMIO) or 12 weeks (12AMIO). Lung tissue strips were analyzed 24 h after the last drug administration. Tissue resistance and elastance were higher in 6AMIO and 12AMIO than in CTRL, while hysteresivity was similar in all groups. Total amount of collagen fibers in lung parenchyma increased progressively with the time course of the lesion. However, at 6 weeks there was an increase in the amount of type III collagen fibers, while in 12AMIO mainly type I collagen fibers were found. In our study amiodarone increased lung tissue impedance that was accompanied by matrix remodeling and lesion of type II pneumocytes. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air pollution is associated with morbidity and mortality induced by respiratory diseases. However, the mechanisms therein involved are not yet fully clarified. Thus, we tested the hypothesis that a single acute exposure to low doses of fine particulate matter (PM2.5) may induce functional and histological lung changes and unchain inflammatory and oxidative stress processes. PM2.5 was collected from the urban area of Sao Paulo city during 24 h and underwent analysis for elements and polycyclic aromatic hydrocarbon contents. Forty-six male BALB/c mice received intranasal instillation of 30 mu L of saline (CTRL) or PM2.5 at 5 or 15 mu g in 30 mu L of saline (P5 and P15, respectively). Twenty-four hours later, lung mechanics were determined. Lungs were then prepared for histological and biochemical analysis. P15 group showed significantly increased lung impedance and alveolar collapse, as well as lung tissue inflammation, oxidative stress and damage. P5 presented values between CTRL and P15: higher mechanical impedance and inflammation than CTRL, but lower inflammation and oxidative stress than P15. In conclusion, acute exposure to low doses of fine PM induced lung inflammation, oxidative stress and worsened lung impedance and histology in a dose-dependent pattern in mice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of microcystin-LR (MCYST-LR)-induced lung inflammation has never been reported Hence. LASSBio 596, an anti-Inflammatory drug candidate, designed as symbiotic agent that modulates TNF-alpha levels and inhibits phosphodiesterase types 4 and 5, or dexamethasone were tested in this condition Swiss mice were intraperitoneally (i p) injected with 60 mu l of saline (CTRL) or a sub-lethal dose of MCYST-LR (40 mu g/kg). 6 h later they were treated (i p.) with saline (TOX), LASSB10 596 (10 mg/kg, L596), or dexamethasone (1 mg/kg, 0.1 mL, DEXA). 8 h after MCYST-LR injection, pulmonary mechanics were determined, and lungs and livers prepared for histopathology, biochemical analysis and quantification of MCYST-LR. TOX showed significantly higher lung impedance than CTRL and L596, which were similar. DEXA could only partially block the mechanical alterations. In both TOX and DEXA alveolar collapse and inflammatory cell influx were higher than in CTRL and L596, being LASSB10 596 more effective than dexamethasone. TOX showed oxidative stress that was not present in an and L596, while DEXA was partially efficient. MCYST-LR was detected in the livers of all mice receiving MCYST-LR and no recovery was apparent In conclusion, LASSBio 596 was more efficient than dexamethasone in reducing the pulmonary functional impairment induced by MCYST-LR. (C) 2010 Elsevier Ltd. All rights reserved