93 resultados para Electronic signature
Resumo:
Recently, the development of industrial processes brought on the outbreak of technologically complex systems. This development generated the necessity of research relative to the mathematical techniques that have the capacity to deal with project complexities and validation. Fuzzy models have been receiving particular attention in the area of nonlinear systems identification and analysis due to it is capacity to approximate nonlinear behavior and deal with uncertainty. A fuzzy rule-based model suitable for the approximation of many systems and functions is the Takagi-Sugeno (TS) fuzzy model. IS fuzzy models are nonlinear systems described by a set of if then rules which gives local linear representations of an underlying system. Such models can approximate a wide class of nonlinear systems. In this paper a performance analysis of a system based on IS fuzzy inference system for the calibration of electronic compass devices is considered. The contribution of the evaluated IS fuzzy inference system is to reduce the error obtained in data acquisition from a digital electronic compass. For the reliable operation of the TS fuzzy inference system, adequate error measurements must be taken. The error noise must be filtered before the application of the IS fuzzy inference system. The proposed method demonstrated an effectiveness of 57% at reducing the total error based on considered tests. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Lipocalins are beta-barrel proteins, which share three conserved motifs in their amino acid sequence. In this study, we identified by a peptide mapping approach, a seven-amino acid sequence related to one of these motifs (motif 2) that modulates cell survival. A synthetic peptide based on an insect lipocalin displayed cytoprotective activity in serum-deprived endothelial cells and leucocytes. This activity was dependent on nitric oxide synthase. This sequence was found within several lipocalins, including apolipoprotein D, retinol binding protein, lipocalin-type prostaglandin D synthase, and many unknown proteins, suggesting that it is a sequence signature and a lipocalin conserved property. (C) 2010 Federation of European Biochemical Societies. Published by Elsevier B. V. All rights reserved.
Resumo:
[Ru(3)O(CH(3)COO)(6)(pz)(CO)](6) is a cyclic hexamer species encompassing six triangular ruthenium cluster centers bridged by pyrazine ligands. The electronic communication among the cluster units strongly depends on their oxidation states, and has been successfully probed by means of cyclic voltammetry and UV-vis spectroelectrochemistry. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Dopamine agonists are the treatment of choice for prolactinomas. However, there are still controversies concerning dose, treatment duration and criteria for drug withdrawal in different clinical situations. The aim of this study was to assess diagnostic and therapeutic approaches to prolactinomas among members of the Brazilian Society of Endocrinology and Metabolism (SBEM). SBEM members answered a questionnaire sent by e-mail that included 18 questions related to controversial issues about the management of prolactinomas. Among SBEM members, 721 (approximately 24% of total) answered the questionnaire. Concerning the diagnosis, 38% of the respondents stated that prolactin levels < 100 ng/ml would exclude the presence of a prolactinoma. Most of them favored the screening for macroprolactin in asymptomatic individuals instead of a routine screening (74% vs. 26%). Regarding the treatment, 70% of the respondents chose cabergoline as the drug of choice to treat macroprolactinomas whereas similar proportions advised cabergoline or bromocriptine as the best treatment for microprolactinomas (52% vs. 48%). Only 20% and 34% of respondents favored treatment withdrawal 2-3 years after prolactin normalization in patients with macroprolactinomas and microprolactinomas, respectively. In case of pregnancy, only 58 and 70% of respondents advocated discontinuation of treatment with dopamine agonists in patients with macroprolactinomas and microprolactinomas, respectively. Finally, only 36% would allow breast-feeding without restriction, 44% would restrict it to patients with microprolactinomas and 20% would not recommend it for women with prolactinomas There are several points of disagreement among SBEM members regarding the management of prolactinomas.
Resumo:
Objective: To propose an electronic method for sensitivity evaluation in leprosy and to compare it to the Semmes-Weinstein monofilaments. Methods:Thirty patients attending the Dermatology outpatient clinic of HCFMRP-USP were consecutively evaluated by both the electronic aesthesiometer and Semmes-Weinstein monofilaments on hand and foot test points. The intraclass correlation coefficient (ICC) was calculated to determine the variability of the electronic measures and the Kappa coefficient was calculated to determine the agreement between methods according to their categories (altered and non-altered tactile sensitivity). Results: The ICC was approximately 1, demonstrating repeatability. The Kappa coefficient showed more than 75 and 63% agreement on the hand and foot points, respectively. The mean agreement between the 2 methods for the 7 points of the right and left hand was 77.14 and 75.71%, respectively. The mean agreement for all 10 points was 74.33 and 63.66% on the right and left foot, respectively. In cases of disagreement the detection of altered tactile sensitivity by the electronic esthesiometer on the right and left foot was 90.91 and 84.25%, respectively, with no detection by the monofilaments. Conclusion: The results suggest that the electronic esthesiometer is a reliable and easy application, capable of evaluating alterations of tactile sensitivity in leprosy patients. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
Audiometry is the main way with which hearing is evaluated, because it is a universal and standardized test. Speech tests are difficult to standardize due to the variables involved, their performance in the presence of competitive noise is of great importance. Aim: To characterize speech intelligibility in silence and in competitive noise from individuals exposed to electronically amplified music. Material and Method: It was performed with 20 university students who presented normal hearing thresholds. The speech recognition rate (SRR) was performed after fourteen hours of sound rest after the exposure to electronically amplified music and once again after sound rest, being studied in three stages: without competitive noise, in the presence of Babble-type competitive noise, in monotic listening, in signal/ noise ratio of + 5 dB and with the signal/ noise ratio of 5 dB. Results: There was greater damage in the SRR after exposure to the music and with competitive noise, and as the signal/ noise ratio decreases, the performance of individuals in the test also decreased. Conclusion: The inclusion of competitive noise in the speech tests in the audiological routine is important, because it represents the real disadvantage experienced by individuals in daily listening.
Resumo:
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
Resumo:
The purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth. Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I - without physiological resorption (n = 16); and Group II - with physiological resorption (n = 18). The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm. For electronic measurement, the devices were set to 1 mm short of the apical resorption. The data were analysed statistically using the intraclass correlation coefficient (ICC). Results showed that the ICC was high for both electronic apex locators in all situations - with (ICC: DSP = 0.82 and Propex = 0.89) or without resorption (ICC: DSP = 0.92 and Propex = 0.90). Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.
Resumo:
P>Aim To evaluate ex vivo the accuracy of the iPex multi-frequency electronic apex locator (NSK Ltd, Tokyo, Japan) for working length determination in primary molar teeth. Methodology One calibrated examiner determined the working length in 20 primary molar teeth (total of 33 root canals). Working length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the most coronal limit of root resorption, and electronically using the electronic apex locator iPex, according to the manufacturers` instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual and the electronic measurements revealed high correlation (ICC = 0.99) between the methods, regardless of the presence or absence of physiological root resorption. Conclusions In this laboratory study, the iPex accurately identified the apical foramen or the apical opening location for working length measurement in primary molar teeth.
Resumo:
As part of a large survey of halo and thick disc stars, we found one halo star, HD106038, exceptionally overabundant in beryllium. In spite of its low metallicity, [Fe/H] = -1.26, the star has log(Be/H) = -10.60, which is similar to the solar meteoritic abundance, log(Be/H)=-10.58. This abundance is more than 10 times higher the abundance of stars with similar metallicity and cannot be explained by models of chemical evolution of the Galaxy that include the standard theory of cosmic ray spallation. No other halo star exhibiting such a beryllium overabundance is known. In addition, overabundances of Li, Si, Ni, Y and Ba are also observed. We suggest that all these chemical peculiarities, excepting the Ba abundance, can be simultaneously explained if the star was formed in the vicinity of a hypernova.
Resumo:
Xanthomonadales comprises one of the largest phytopathogenic bacterial groups, and is currently classified within the gamma-proteobacteria. However, the phylogenetic placement of this group is not clearly resolved, and the results of different studies contradict one another. In this work, the evolutionary position of Xanthomonadales was determined by analyzing the presence of shared insertions and deletions (INDELs) in highly conserved proteins. Several distinctive insertions found in most of the members of the gamma-proteobacteria are absent in Xanthomonadales and groups such as Legionelalles, Chromatiales, Methylococcales, Thiotrichales and Cardiobacteriales. These INDELs were most likely introduced after the branching of Xanthomonadales from most of the gamma-proteobacteria and provide evidence for the phylogenetic placement of the early gamma-proteobacteria. Moreover, other proteins contain insertions exclusive to the Xanthomonadales order, confirming that this is a monophyletic group and provide important specific genetic markers. Thus, the data presented clearly support the Xanthomonadales group as an independent subdivision, and constitute one of the deepest branching lineage within the gamma-proteobacteria clade. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Electronic polarization of the acetone molecule in the excited n -> pi* state is considered and its influence on the solvent shift in the emission spectrum is analyzed. Using an iterative procedure the electronic polarizations of both the ground and the excited states are included and compared with previous results obtained with Car-Parrinello dynamics. Analysis of the emission transition obtained using CIS(D)/aug-cc-pVDZ on statistically uncorrelated solute-solvent structures, composed of acetone and twelve explicit water molecules embedded in the electrostatic field of remaining 263 water molecules, corroborates that the solvent effect is mild, calculated here between 80 and 380 cm (1). (c) 2010 Published by Elsevier B.V.