284 resultados para MASS DETECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports theoretical and experimental studies of gas-phase fragmentation reactions of four naturally occurring isoflavones. The samples were analyzed in negative ion mode by direct infusion in ESI-QqQ, ESI-QqTOF and ESI-Orbitrap systems. The MS/MS and MS(n) spectra are in agreement with the fragmentation proposals and high-resolution analyses have confirmed the formulae for each ion observed. As expected, compounds with methoxyl aromatic substitution have showed a radical elimination of center dot CH(3) as the main fragmentation pathway. A second radical loss (center dot H) occurs as previously observed for compounds which exhibit a previous homolytic center dot CH(3) cleavage (radical anion) and involves radical resonance to stabilize the anion formed. However, in this study we suggest another mechanism for the formation of the main ions, on the basis of the enthalpies for each species. Compounds without methoxy substituent dissociate at the highest energies and exhibit the deprotonated molecule as the most intense ion. Finally, energy-resolved experiments were carried out to give more details about the gas-phase dissociation reaction of the isoflavones and the results are in agreement with the theoretical approaches. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The beta-carbolines 1-methyl-9H-pyrido [3,4-b]indole and 9H-pyrido[3,4b]indole have been implicated as having causative roles in a number of human diseases, such as Parkinson`s disease and cancer. As they can be formed during the heating of protein-rich food, a number of analytical methodologies have been proposed for their detection and quantification in foodstuff For this purpose, LC-MS and LC-MS/MS have emerged as the most specific analytical methods, and the quantification is based on the occurrence of unusual ions, such as [M+H-(H(center dot))](+) and [M + H-2H](+). In this study, we have investigated the formation of these ions by accurate-mass electrospray MS/MS and demonstrated that these ions are formed from gas-phase ion-molecule reactions between water vapor present in the collision cell and the protonated molecule of 1-methyl-9H-pyrido [3,4-b]indole and 9H-pyrido[3,4b]indole. Although this reaction has been previously described for heterocyclic amine ions, it has been overlooked in the most of recent LC-MS and LC-MS/MS studies, and no complete data of the fragmentation are reported. Our results demonstrate that additional attention should be given with respect to eliminating water vapor residues in the mass spectrometer when analysis of beta-carbolines is performed, as this residue may affect the reliability in the results of quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A liquid chromatography method is described for the analysis of fluoxetine and norfluoxetine enantiomers in fungi cultures. The analytes were separated simultaneously by LC employing a serial system. The resolution was performed using a mobile phase of ethanol: 15 mM ammonium acetate buffer solution, pH 5.9: acetonitrile (77.5:17.5:5, v/v/v). UV detection was at 227 nm. Hexane: isoamyl alcohol (98:2, v/v) was used as extractor solvent. The calibration curves were linear over the concentration range of 12.5-3,750 ng mL(-1) (r a parts per thousand yen 0.996). The values for intra- and inter-day precision and accuracy were a parts per thousand currency sign10% for all analytes. The validated method was used to evaluate fluoxetine biotransformation to its mammalian metabolite, norfluoxetine, by selected endophytic fungi. Although the desired biotransformation was not observed in the conditions used here, the method could be used to evaluate the biotransformation of fluoxetine by other fungi or to be extended to other matrices with adequate procedures for sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method was optimized and validated for determination of ractopamine hydrochloride (RAC) in raw material and feed additives by HPLC for use in quality control in veterinary industries. The best-optimized conditions were a C8 column (250 x 4.6 mm id, 5.0 mu m particle size) at room temperature with acetonitrile-100 mM sodium acetate buffer (pH 5.0; 75 + 25, v/v) mobile phase at a flow rate of 1.0 mL/min and UV detection at 275 nm. With these conditions, the retention time of RAC was around 5.2 min, and standard curves were linear in the concentration range of 160-240 mu g/mL (correlation coefficient >= 0.999). Validation parameters, such as selectivity, linearity, limit of detection (ranged from 1.60 to 2.05 mu g/mL), limit of quantification (ranged from 4.26 to 6.84 mu g/mL), precision (relative standard deviation <= 1.87%), accuracy (ranged from 96.97 to 100.54%), and robustness, gave results within acceptable ranges. Therefore, the developed method can be successfully applied for the routine quality control analysis of raw material and feed additives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for simultaneous determination of seven benzodiazepines (BZPs) (flunitrazepam, clonazepam, oxazepam, lorazepam, chlordiazepoxide, nordiazepam and diazepam using N-desalkylflurazepam as internal standard) in human plasma using liquid-liquid and solid-phase extractions followed by high-performance liquid chromatography (HPLC) is described. The analytes were separated employing a LC-18 DB column (250 mm x 4.6 mm, 5 mu m) at 35 degrees C under isocratic conditions using 5 mM KH(2)PO(4) buffer solution pH 6.0: methanol: diethyl ether (55:40:5, v/v/v) as mobile phase at a flow rate of 0.8 mL min(-1). UV detection was carried out at 245 nm. Employing LLE, the best conditions were achieved with double extraction of 0.5 mL, plasma using ethyl acetate and Na(2)HPO(4) pH 9.5 for pH adjusting. Employing SPE, the best conditions were achieved with 0.5 mL plasma plus 3 mL 0.1 M borate buffer pH 9.5, which were then passed through a C18 cartridge previously conditioned, washed for 3 times with these solvents: 3 mL 0.1 M borate buffer pH 9.5,4 mL Milli-Q water and 1 mL acetonitrile 5%, finally the BZPs elution was carried with diethyl ether: n-hexane: methanol (50:30:20). In both methods the solvent was evaporated at 40 degrees C under nitrogen flow. The validation parameters obtained in LLE were linearity range of 50-1200 ng mL(-1) plasma (r >= 0.9927), limits of quantification of 50 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15%, and recovery above 65% for all BZPs. In SPE, the parameter obtained were linearity range of 30-1200 ng mL(-1) plasma (r >= 0.9900), limits of quantification of 30 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15% and recovery above 55% for all BZPs. These extracting procedures followed by HPLC analysis showed their suitable applicability in order to examine one or more BZPs in human plasma. Moreover, it could be suggested that these procedures might be employed in various analytical applications, in special for toxicological/forensic analysis. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospray ionization mass spectrometric analysis of lapachol (2-hydroxy-3-(3-methy1-2-butenyl)-1,4-naphthoquinone) was accomplished in order to elucidate the gas-phase dissociation reactions of this important biologically active natural product. The occurrence of protonated and cationized species in the positive mode and of deprotonated species in the negative mode was explored by means of collision-induced dissociation (CID) experiments. For the protonated molecule, the H(2)O and C(4)H(8) losses occur by two competitive channels. For the deprotonated molecule, the even-electron rule is not conserved, and the radicalar species are eliminated by formation of distonic anions. The fragmentation mechanism for each ion was suggested on the basis of computational thermochemistry. Atomic charges, relative energies, and frontier orbitals were employed aiming at a better understanding of the gas-phase reactivity of lapachol. Potential energy surfaces for fragmentation reactions were obtained by the B3LYP/6-31+G(d,p) model. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nostocalean nitrogen-fixing cyanobacterium isolated from an eutrophic freshwater reservoir located in Piracicaba, Sao Paulo, Brazil, was evaluated for the production of hepatotoxic cyclic heptapeptides, microcystins. Morphologically this new cyanobacterium strain appears closest to Nostoc, however, in the phylogenetic analysis of 165 rRNA gene it falls into a highly stable cluster distantly only related to the typical Nostoc cluster. Extracts of Nostoc sp. CENA88 cultured cells, investigated using ELISA assay, gave positive results and the microcystin profile revealed by ESI-Q-TOF/MS/MS analysis confirmed the production of [Dha(7)]MCYST-YR. Further, Nostoc sp. CENA88 genomic DNA was analyzed by PCR for sequences of mcyD, mcyE and mcyG genes of microcystin synthetase (mcy) cluster. The result revealed the presence of mcyD, mcyE and mcyG genes with similarities to those from mcy of Nostoc sp. strains 152 and IO-102-I and other cyanobacterial genera. The phylogenetic tree based on concatenated McyG, McyD and McyE amino acids clustered the sequences according to cyanobacterial genera, with exception of the Nostoc sp. CENA88 sequence, which was placed in a clade distantly related from other Nostoc strains, as previously observed also in the 165 rRNA phylogenetic analysis. The present study describes for the first time a Brazilian Nostoc microcystin producer and also the occurrence of demethyl MCYST-YR variant in this genus. The sequenced Nostoc genes involved in the microcystin synthesis can contribute to a better understanding of the toxigenicity and evolution of this cyanotoxin. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports the synthesis, characterization, and evaluation of new porphyrins tailored to become biodiesel fluorescent markers. The compounds were obtained by the synthetic modification of the commercially available porphyrin 5,10,15,20-meso-tetrakis(pentafluorophenyl)porphyrin (TPPF(20)) using ethanol and hexadecan-1-ol (cetylic alcohol) as nucleophilic reagents. The stability of the marked biodiesel fuel solutions was investigated every 15 days for a total period of 3 months, and under different storage temperature and light exposure condition, simulating the conventional stock conditions. The influence of the different substituents of the porphyrins on the fluorescence properties of the biodiesel fuel markers was also assessed. The resulting porphyrins were highly soluble in biodiesel fuel and displayed strong fluorescence characterized by two strong emission bands. The fluorescent markers did not affect the biodiesel physical properties and were stable in storage conditions for at least 3 months at a concentration of 4 ppm. The best storage condition was found to be absence of light and 6 degrees C; the limit of detection by photoluminescence technique had magnitude of 10(-13) mol L(-1). The synthesized porphyrins were characterized by nuclear magnetic resonance ((1)H-NMR and (19)F-NMR), mass spectrometry (HRMS), ultraviolet visible absorption spectroscopy, and photoluminescence spectroscopy. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The novel asymmetric metallo-organic triads cis- and trans-[B(4-py)BPFPH(2){Ru(3)O(Ac)(6)(py)(2)}(Ru(bpy)(2)Cl}](PF(6))(2) (5a,b) for which cis- and trans-B(4-py)BPFPH(2)=5,10-bis(pentafluorophenyl)-15,20-bis(4-pyridyl)porphyrin and 5,15-bis(pentafluorophenyl)-10,20-bis(4-pyridyl)porphyrin, respectively; Ac = acetate; py = pyridine and bpy = 2,2`-bipyridine, as well as their corresponding monosubstituted dyads cis- and trans-[B(4-py)BPFPH(2){Ru(3)O(Ac)(6)(py)(2)}]PF(6) (4a,b) have been structurally characterized via electrospray ionization mass spectrometry (ESI-MS and ESI-MS/MS). The ESI-MS of dyads 4a,b display two characteristic Ru-multicomponent clusters of isotopologue ions corresponding to singly charged ions 4a,b(+) of m/z 1629 and doubly charged ions [4a,b+H](2+) of m/z 815 and the triads 5a,b are detected by ESI-MS as the intact doubly charged cluster of isotopologue ions of m/z 1039 [5a,b](2+). The ESI-MS/MS of 4a,b(+), [4a,b+H](2+) and [5a,b](2+) reveal characteristic dissociation pathways, which confirm the structural assignments providing additional information on the intrinsic binding strengths of the gaseous ions. Although the gas-phase behavior of each pair of isomers was rather similar, the less symmetric dyads 4a,b are distinguished via the (1)H NMR spectral profile of the pyrrolic signals. Exploratory photophysical assays have shown that both modifying motifs alter the porphyrinic core emission profile, opening the possibility to use these asymmetric systems as photophysical devices. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.