14 resultados para photography of camps
em Universidad de Alicante
Resumo:
Background To analyze and compare the relationship between anterior and posterior corneal shape evaluated by a tomographic system combining the Scheimpflug photography and Placido-disc in keratoconus and normal healthy eyes, as well as to evaluate its potential diagnostic value. Methods Comparative case series including a sample of 161 eyes of 161 subjects with ages ranging from 7 to 66 years and divided into two groups: normal group including 100 healthy eyes of 100 subjects, and keratoconus group including 61 keratoconus eyes of 61 patients. All eyes received a comprehensive ophthalmologic examination including an anterior segment analysis with the Sirius system (CSO). Antero-posterior ratios for corneal curvature (k ratio) and shape factor (p ratio) were calculated. Logistic regression analysis was used to evaluate if some antero–posterior ratios combined with other clinical parameters were predictors of the presence of keratoconus. Results No statistically significant differences between groups were found in the antero–posterior k ratios for 3-, 5- and 7-mm diameter corneal areas (p ≥ 0.09). The antero–posterior p ratio for 4.5- and 8-mm diameter corneal areas was significantly higher in the normal group than in the keratoconus group (p < 0.01). The k ratio for 3, 5, and 7 mm was significantly higher in the keratoconus grade IV subgroup than in the normal group (p < 0.01). Furthermore, significant differences were found in the p ratio between the normal group and the keratoconus grade II subgroup (p ≤ 0.01). Finally, the logistic regression analysis identified as significant independent predictors of the presence of keratoconus (p < 0.01) the 8-mm anterior shape factor, the anterior chamber depth, and the minimal corneal thickness. Conclusions The antero-posterior k and p ratios are parameters with poor prediction ability for keratoconus, in spite of the trend to the presence of more prolate posterior corneal surfaces compared to the anterior in keratoconus eyes.
Resumo:
Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.
Resumo:
Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.
Resumo:
To validate clinically an algorithm for correcting the error in the keratometric estimation of corneal power by using a variable keratometric index of refraction (nk) in a normal healthy population.
Resumo:
Elysia timida (Risso, 1818) colonizing the shallow waters of the Mar Menor Lagoon (Spain) exhibit a brown and a green morph. It was hypothesised that these morphs were the result of feeding preferentially on brown and green algae, respectively. E. timida and its potential food sources, Acetabularia acetabulum (Chlorophyta) and Halopteris filicina (Heterokontophyta) were collected by snorkelling during April 2010. Photosynthetic pigments were analysed by HPLC, photo-physiological parameters were estimated by PAM fluorometry and body colour was characterized by spectral reflectance. Digital photography was used to count the number and area of red spots (small red dots on the slug’s surface) on the parapodia of the 2 morphs. In the laboratory, green E. timida was fed with A. acetabulum cultured under 2 light treatments (high light, 600 µmol E m−2 s−1 and low light, 40 µmol E m−2 s−1), and digital photography was used to monitor colour alterations in E. timida. Spectral reflectance confirmed the colour differences, but both morphs showed a pigment composition similar to the green alga A. acetabulum and showed none of the pigments present in the brown alga H. filicina, neither immediately after collection of the slugs in situ, nor after the feeding experiment. A. acetabulum grown under high light intensity changed from green to brown colour and E. timida changed to brown colour when fed with high-light acclimated A. acetabulum. Thus, E. timida colour differences could not be attributed to feeding on different algae groups but was likely the result of feeding on A. acetabulum growing under different light intensities.
Reverse Geometry Hybrid Contact Lens Fitting in a Case of Donor-Host Misalignment after Keratoplasty
Resumo:
Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.
Resumo:
Corneal and anterior segment imaging techniques have become a crucial tool in the clinical practice of ophthalmology, with a great variety of applications, such as corneal curvature and pachymetric analysis, detection of ectatic corneal conditions, anatomical study of the anterior segment prior to phakic intraocular lens implantation, or densitometric analysis of the crystalline lens. From the Placido-based systems that allow only a characterization of the geometry of the anterior corneal surface to the Scheimpflug photography-based systems that provide a characterization of the cornea, anterior chamber, and crystalline lens, there is a great variety of devices with the capability of analyzing different anatomical parameters with very high precision. To date, Scheimpflug photography-based systems are the devices providing the more complete analysis of the anterior segment in a non-invasive way. More developments are required in anterior segment imaging technologies in order to improve the analysis of the crystalline lens structure as well as the ocular structures behind the iris in a non-invasive way when the pupil is not dilated.
Resumo:
Purpose: To evaluate the correlation of the magnitude of corneal toricity and power vector components of both corneal surfaces measured with a Scheimpflug photography-based system. Methods: A total of 117 healthy normal eyes of 117 subjects selected randomly with ages ranging from 7 to 80 years were included. All eyes received an anterior segment and corneal analysis with the Sirius system (CSO) evaluating the anterior and posterior mean toricity for 3 and 7 mm (aAST and pAST). The vector components J0 and J45 as well as the overall strength blur (B) were calculated for each keratometric measurement using the procedure defined by Thibos and Horner. Results: The coefficient of correlation between aAST and pAST was 0.52 and 0.62 and the mean anteroposterior ratio for toricity was 0.46 ± 0.39 and 0.57 ± 0.75 for 3 and 7 mm, respectively. These ratios correlated significantly with aAST, anterior corneal J0, and manifest refraction J0 (r ≥ 0.39, P < 0.01). The coefficient of correlation was 0.69 and 0.81 between anterior and posterior J0 for 3 and 7 mm, respectively. For J45, the coefficients were 0.62 and 0.71, respectively. The linear regression analysis revealed that the pAST and power vectors could be predicted from the anterior corneal data (R2 ≥ 0.40, P < 0.01). Conclusions: The toricity and astigmatic power vector components of the posterior corneal surface in the human healthy eye are related to those of the anterior and therefore can be predicted consistently from the anterior toricity and astigmatic power vectors.
Resumo:
Purpose: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography–based system in keratoconus eyes. Methods: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth. Results: Mean aKM/pKM ratio around 1.20 (range, 0.95–1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between −0.28 and −0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R2 ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R2 = 0.89, P < 0.01). Conclusions: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.
Resumo:
The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. Methods: The nkexact value was determined by obtaining differences (DPc) between keratometric corneal power (Pk) and Gaussian corneal power (PGauss c ) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of DPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with PGauss c , Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. Results: nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and PGauss c did not exceed 60.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadj and True Net Power and Pk(1.3375) and Pkadj were statistically different (P , 0.01), whereas no differences were found between PGauss c and Pkadj (P . 0.01). Conclusions: The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.
Resumo:
AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Resumo:
Purpose. To validate clinically a new method for estimating the corneal power (P,) using a variable keratometric index (nkadj) in eyes with previous laser refractive surgery. Setting. University of Alicante and Medimar International Hospital (Oftalmar), Alicante, (Spain). Design. Retrospective case series. Methods. This retrospective study comprised 62 eyes of 62 patients that had undergone myopic LASIK surgery. An algorithm for the calculation of 11kadj was used for the estimation of the adjusted keratometric corneal power (Pkadj). This value was compared with the classical keratometric corneal power (Pk), the True Net Power (TNP), and the Gaussian corneal power (PcGauss). Likewise, Pkadj was compared with other previously described methods. Results. Differences between PcGauss and P, values obtained with all methods evaluated were statistically significant (p < 0.01). Differences between Pkadj and PcGauss were in the limit of clinical significance (p < 0.01, loA [ - 0.33,0.60] D). Differences between Pkadj and TNP were not statistically and clinically significant (p = 0.319, loA [- 0.50,0.44] D). Differences between Pkadj and previously described methods were statistically significant (p < 0.01), except with PcHaigisL (p = 0.09, loA [ - 0.37,0.29] D). Conclusion. The use of the adjusted keratometric index (nkadj) is a valid method to estimate the central corneal power in corneas with previous myopic laser refractive surgery, providing results comparable to PcHaigisL.
Resumo:
Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.
Resumo:
Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.