257 resultados para Farmacología.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, a novel kind of hybrid pigment based on nanoclays and dyes was synthesized and characterized. These nanoclay-based pigments (NCPs) were prepared at the laboratory with sodium montmorillonite nanoclay (NC) and methylene blue (MB). The cation-exchange capacity of NC exchanged with MB was varied to obtain a wide color gamut. The synthesized nanopigments were thoroughly characterized. The NCPs were melt-mixed with linear low-density polyethylene (PE) with an internal mixer. Furthermore, samples with conventional colorants were prepared in the same way. Then, the properties (mechanical, thermal, and colorimetric) of the mixtures were assessed. The PE–NCP samples developed better color properties than those containing conventional colorants and used as references, and their other properties were maintained or improved, even at lower contents of dye compared to that with the conventional colorants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New color-measuring instruments known as multiangle spectrophotometers have been recently created to measure and characterize the goniochromism of special-effect pigments in many materials with a particular visual appearance (metallic, interference, pearlescent, sparkle, or glitter). These devices measure the gonioapparent color from the spectral relative reflectance factor and the L*a*b* values of the sample with different illumination and observation angles. These angles usually coincide with requirements marked in American Society for Testing and Materials (ASTM) and Deutsches Institut Für Normung standards relating to the gonioapparent color, but the results of comparisons between these instruments are still inconclusive. Therefore, the main purpose of this study is to compare several multiangle spectrophotometers at a reproducibility level according to ASTM E2214-08 guidelines. In particular, we compared two X-Rite multi-gonio spectrophotometers (MA98 and MA68II), a Datacolor multi-gonio spectrophotometer (FX10), and a BYK multi-gonio spectrophotometer (BYK-mac). These instruments share only five common measurement geometries: 45° × −30° (as 15°), 45° × −20° (as 25°), 45° × 0° (as 45°), 45° × 30° (as 75°), 45° × 65° (as 110°). Specific statistical studies were used for the reproducibility comparison, including a Hotelling test and a statistical intercomparison test to determine the confidence interval of the partial color differences ΔL*, Δa*, Δb*, and the total color difference ΔE*ab. This was conducted using a database collection of 88 metallic and pearlescent samples that were measured 20 times without the replacement of all the instruments. The final findings show that in most measurement geometries, the reproducibility differences between pairs of instruments are statistically significant, although in general, there is a better reproducibility level at certain common geometries for newer instruments (MA98 and BYK-mac). This means that these differences are due to systematic or bias errors (angle tolerances for each geometry, photometric scales, white standards, etc.), but not exclusively to random errors. However, neither of the statistical tests used is valid to discriminate and quantify the detected bias errors in this comparison between instruments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We rigorously analyze the propagation of localized surface waves that takes place at the boundary between a semi-infinite layered metal-dielectric (MD) nanostructure cut normally to the layers and a isotropic medium. It is demonstrated that Dyakonov-like surface waves (also coined dyakonons) with hybrid polarization may propagate in a wide angular range. As a consequence, dyakonon-based wave-packets (DWPs) may feature sub-wavelength beamwidths. Due to the hyperbolic-dispersion regime in plasmonic crystals, supported DWPs are still in the canalization regime. The apparent quadratic beam spreading, however, is driven by dissipation effects in metal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, a digital CMOS camera was calibrated for use as a non-contact colorimeter for measuring the color of granite artworks. The low chroma values of the granite, which yield similar stimulation of the three color channels of the camera, proved to be the most challenging aspect of the task. The appropriate parameters for converting the device-dependent RGB color space into a device-independent color space were established. For this purpose, the color of a large number of Munsell samples (corresponding to the previously defined color gamut of granite) was measured with a digital camera and with a spectrophotometer (reference instrument). The color data were then compared using the CIELAB color formulae. The best correlations between measurements were obtained when the camera works to 10-bits and the spectrophotometric measures in SCI mode. Finally, the calibrated instrument was used successfully to measure the color of six commercial varieties of Spanish granite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Evaluar los resultados obtenidos mediante el empleo de los filtros de Bangerter en casos de ambliopía media o moderada asociada a estrabismo. Material y métodos: Se realizó un estudio prospectivo con 30 pacientes de edades comprendidas entre 2 y 9 años con ambliopía media o moderada unilateral asociada a estrabismo. Todos los pacientes fueron tratados mediante la prescripción del empleo de filtros de Bangerter en el ojo no ambliope junto a su corrección refractiva. En todos los casos el filtro seleccionado indujo una reducción de la agudeza visual de 2 líneas por debajo de la agudeza visual corregida (AVCC) del ojo ambliope. Se realizó un seguimiento durante un periodo de 12 meses. Resultados: Se observó una mejoría estadísticamente significativa en la AVCC del ojo ambliope a los 3 meses (p<0.01), con mejorías adicionales a los 6, 9 y 12 meses (p≤0,02).La AVCC en los ojos no ambliopes permaneció sin cambios durante los primeros 6 meses de tratamiento (p≥0,52), con una mejoría significativa a los 9 meses (p=0,03). Sólo se evidenciaron diferencias significativas en la AVCC entre los ojos ambliopes y los ojos sanos a los 3 meses tras el uso de los filtros (p<0,01). La densidad del filtro tuvo que ser cambiada durante el seguimiento en 12 ojos (40%). Se encontró correlación inversa significativa entre la densidad del filtro y la AVCC al final del seguimiento (r≤-0,35, p≤0,01).Conclusiones: Los filtros de Bangerter son útiles para el tratamiento de la ambliopía media o moderada asociada a estrabismo, si bien la inversión de la dominancia ocular debe ser mantenida a lo largo del tratamiento para optimizar los resultados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Presentamos un caso de ambliopía unilateral en una paciente de 7 años, no existiendo alteraciones refractivas, corneales o retinianas que lo justifiquen. La exploración mediante tecnología de cámara Scheimpflug permitió el diagnóstico de un Ienticono posterior asociado a una pequeña catarata congénita polar posterior. El estudio aberrométrico reveló la importancia óptica de dicha condición como causante de la ambliopía en este caso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the correlation of the magnitude of corneal toricity and power vector components of both corneal surfaces measured with a Scheimpflug photography-based system. Methods: A total of 117 healthy normal eyes of 117 subjects selected randomly with ages ranging from 7 to 80 years were included. All eyes received an anterior segment and corneal analysis with the Sirius system (CSO) evaluating the anterior and posterior mean toricity for 3 and 7 mm (aAST and pAST). The vector components J0 and J45 as well as the overall strength blur (B) were calculated for each keratometric measurement using the procedure defined by Thibos and Horner. Results: The coefficient of correlation between aAST and pAST was 0.52 and 0.62 and the mean anteroposterior ratio for toricity was 0.46 ± 0.39 and 0.57 ± 0.75 for 3 and 7 mm, respectively. These ratios correlated significantly with aAST, anterior corneal J0, and manifest refraction J0 (r ≥ 0.39, P < 0.01). The coefficient of correlation was 0.69 and 0.81 between anterior and posterior J0 for 3 and 7 mm, respectively. For J45, the coefficients were 0.62 and 0.71, respectively. The linear regression analysis revealed that the pAST and power vectors could be predicted from the anterior corneal data (R2 ≥ 0.40, P < 0.01). Conclusions: The toricity and astigmatic power vector components of the posterior corneal surface in the human healthy eye are related to those of the anterior and therefore can be predicted consistently from the anterior toricity and astigmatic power vectors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate postoperative spectral-domain optical coherence tomography findings after macular hole surgery. Methods: Retrospective, interventional, nonrandomized study. Overall, 164 eyes of 157 patients diagnosed with macular hole were operated on by vitrectomy and internal limiting membrane peeling. Preoperative and postoperative best-corrected visual acuity and spectral-domain optical coherence tomography images were obtained. Two groups were considered on the basis of the postoperative integrity of the back reflection line from the ellipsoid portion of the photoreceptor inner segment: group A (disruption of ellipsoid portion of the inner segment line, 60 eyes) and group B (restoration of ellipsoid portion of the inner segment line, 104 eyes). Results: Logarithm of the minimum angle of resolution best-corrected visual acuity improved significantly after the surgery of macular hole from a mean preoperative value of 0.79 ± 0.37 (range, 0.15–2.00) to a mean postoperative value of 0.35 ± 0.31 (range, 0.00–1.30) at the last follow-up visit (P < 0.01). Best-corrected visual acuity improved significantly in the 2 groups analyzed (all P < 0.01). A larger improvement was found in group B than in group A (P < 0.01). Conclusion: Ellipsoid portion of the inner segment line reconstruction seems to be a good prognostic factor for visual rehabilitation after macular hole surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualmente, la adaptación de lentes de contacto nos ofrece una buena solución óptica para anisometropías, ya que se consigue igualar el tamaño de las imágenes retinianas, astigmatismos irregulares, consiguiendo regularizar la superficie corneal anterior, en miopías medias y elevadas, porque se logra un mayor tamaño de imagen retiniana respecto a la lente oftálmica, en casos de hipermetropías altas o afaquias, al conseguir un aumento del campo visual, y en nistagmus, ya que la lente acompaña al movimiento del ojo. A continuación, presentamos un caso de rehabilitación visual completa con la adaptación de una lente de contacto híbrida de geometría inversa en una córnea operada de cirugía LASIK miópica fallida, que tuvo como consecuencia una inducción muy significativa de irregularidad corneal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La lente híbrida de geometría inversa PS ofrece una mejoría de la calidad visual en pacientes con córneas irregulares tras cirugía refractiva miópica, mostrándose como una excelente opción en aquellos casos en que el insuficiente lecho corneal imposibilita retratamientos posteriores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La disponibilidad de nuevas herramientas multimedia favorece la generación de material docente auxiliar para la enseñanza de las diversas materias y puede suponer un aliciente añadido para el estudiante. Así, además de fomentar su interés por la materia, se puede potenciar su aprendizaje autónomo. Con el objetivo de evaluar las ventajas de la visualización de vídeos como apoyo a las explicaciones teóricas se planteó la siguiente experiencia: con alumnos de la asignatura "Farmacología", del Grado en Óptica y Optometría, se analizó y comparó la comprensión de la materia con y sin la visualización de vídeos como material de apoyo. El análisis mediante cuestionarios mostró que la visualización ayudó a fijar los conocimientos previamente adquiridos. El 79% de los estudiantes consideró que los vídeos les ayudaron a conseguir una mejor comprensión de la materia. El 95% de los alumnos consideró más útil escuchar primero la explicación del docente. El profesorado implicado manifiesta la dificultad de la selección de material óptimo debido su escasez, por lo que resulta conveniente la elaboración de material específico. Podemos concluir que el material audiovisual supone una buena herramienta complementaria para las clases teóricas, si bien debe integrarse de forma adecuada en el desarrollo de la clase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En el marco del proyecto de Redes de Investigación en Docencia Universitaria 2013-14 de la Universidad de Alicante se creó una red de trabajo formada por los profesores coordinadores de semestre del Grado en Óptica y Optometría y dos alumnos. Dado que durante el curso académico 2013-14 ha tenido lugar la implantación del último curso del Grado en Óptica y Optometría, el objetivo principal de esta red ha sido la realización de un análisis de la implantación del título así como el estudio del diseño y desarrollo del Trabajo Fin de Grado y del programa de Prácticas Externas. Para ello se han recogido las sugerencias y propuestas realizadas a través de las comisiones de semestres, de la comisión de garantía de calidad y de reuniones con el alumnado, con el fin de optimizar el funcionamiento del título, tanto en la distribución de contenidos, como en las metodologías docentes y de evaluación de las distintas materias que componen el plan de estudios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Durante el curso 2013-2014 la Universidad de Alicante ha propuesto la implantación del Master en Optometría Avanzada y Salud Visual, dicha solicitud está siendo actualmente evaluada por la ANECA. Con el fin de coordinar la docencia de este Máster y dentro del Proyecto de Redes de Investigación en Docencia Universitaria 2013-2014, se ha creado una red formada por todos los profesores que han participado en la elaboración del plan de estudios. En esta red esta red se pretende la coordinación entre las distintas asignaturas para elaborar las guías docentes a partir de los datos de las fichas enviadas a la ANECA. Por otra parte también se ha modificado la memoria atendiendo a las alegaciones realizadas por la ANECA. Y se han desarrollado los contenidos, la metodología de las distintas actividades propuestas con el fin de asegurar la consecución de las competencias previstas.