202 resultados para MEV RANGE 01-10


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the discovery of a 61-Jupiter-mass brown dwarf (BD), which transits its F8V host star, WASP-30, every 4.16 days. From a range of age indicators we estimate the system age to be 1-2 Gyr. We derive a radius (0.89 ± 0.02 R Jup) for the companion that is consistent with that predicted (0.914 R Jup) by a model of a 1 Gyr old, non-irradiated BD with a dusty atmosphere. The location of WASP-30b in the minimum of the mass-radius relation is consistent with the quantitative prediction of Chabrier & Baraffe, thus confirming the theory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report calculations of energy levels, radiative rates and electron impact excitation rates for transitions in H-like N VII, O VIII, F IX, Ne X and Na XI. The general-purpose relativistic atomic structure package (grasp) is adopted for calculating energy levels and radiative rates, while the Dirac atomic R-matrix code (DARC) and the flexible atomic code (FAC) are used for determining the collision strengths and subsequently the excitation rates. Oscillator strengths, radiative rates and line strengths are listed for all E1, E2, M1 and M2 transitions among the lowest 25 levels of the above five ions. Collision strengths have been averaged over a Maxwellian velocity distribution, and the effective collision strengths so obtained are reported over a wide temperature range below 10(7) K. Additionally, lifetimes are also given for all the calculated energy levels of the above five ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report calculations of energy levels, radiative rates and electron impact excitation rates for transitions in Li-like N V, F VII, Ne VIII and Na IX. The general-purpose relativistic atomic structure package (GRASP) is adopted for calculating energy levels and radiative rates, while for determining the collision strengths and subsequently the excitation rates, the Dirac atomic R-matrix code (DARC) and the flexible atomic code (FAC) are used. Oscillator strengths, radiative rates and line strengths are reported for all E1, E2, M1 and M2 transitions among the lowest 24 levels of N V, F VII, Ne VIII and Na IX. Collision strengths have been averaged over a Maxwellian velocity distribution and the effective collision strengths so obtained are reported over a wide temperature range below 10(6.6) K. Additionally, lifetimes are also reported for all calculated levels of the above four ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ultrashort duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen's University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 109Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4±0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ultra short duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen's University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 10 Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live, cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4±0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design, development and evaluation of an optical fibre pH sensor for monitoring pH in the alkaline region are discussed in detail in this paper. The design of this specific pH sensor is based on the pH induced change in fluorescence intensity of a coumarin imidazole dye which is covalently attached to a polymer network and then fixed to the distal end of an optical fibre. The sensor provides a response over a pH range of 10.0–13.2 with an acceptable response rate of around 50 min, having shown a very good stability over a period of longer than 20 months thus far. The sensor has also demonstrated little cross-sensitivity to ionic strength (IS) and also excellent photostability through a series of laboratory tests. These features make this type of sensor potentially well suited for in situ long term monitoring of pH in concrete structures, to enhance structural monitoring in the civil engineering sector

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Constitutive equations including an Arrhenius term have been applied to analyze the hot deformation behavior of a nitride-strengthened (NS) martensitic heat resistant steel in temperature range of 900–1200 °C and strain rate range of 0.001–10 /s. On the basis of analysis of the deformation data, the stress–strain curves up to the peak were divided into four regions, in sequence, representing four processes, namely hardening, dynamic recovery (DRV), dynamic strain induced transformation (DSIT), and dynamic recrystallization (DRX), according to the inflection points in ∂θ/∂σ∂θ/∂σ and ∂(∂θ/∂σ)/∂σ∂(∂θ/∂σ)/∂σ curves. Some of the inflection points have their own meanings. For examples, the minimum of ∂θ/∂σ∂θ/∂σ locates the start of DRV and the maximum of it indicates the start of DRX. The results also showed that the critical strain of DRX was sensitive to ln(Z) below 40, while the critical stress of DRX was sensitive to it above 40. The final microstructures under different deformation conditions were analyzed in terms of softening processes including DRV, DRX, metadynamic crystallization (MDRX) and DSIT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new field-programmable gate array (FPGA) identification generator circuit is introduced based on physically unclonable function (PUF) technology. The new identification generator is able to convert flip-flop delay path variations to unique n-bit digital identifiers (IDs), while requiring only a single slice per ID bit by using 1-bit ID cells formed as hard-macros. An exemplary 128-bit identification generator is implemented on ten Xilinx Spartan-6 FPGA devices. Experimental results show an uniqueness of 48.52%, and reliability of 92.41% over a 25°C to 70°C temperature range and 10% fluctuation in supply voltage

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cao et al. reported a possible progenitor detection for the Type Ib supernovae iPTF13bvn for the first time. We find that the progenitor is in fact brighter than the magnitudes previously reported by approximately 0.7-0.2 mag with a larger error in the bluer filters. We compare our new magnitudes to our large set of binary evolution models and find that many binary models with initial masses in the range of 10-20M(circle dot) match this new photometry and other constraints suggested from analysing the supernova. In addition, these lower mass stars retain more helium at the end of the model evolution indicating that they are likely to be observed as Type Ib supernovae rather than their more massive, Wolf-Rayet counter parts. We are able to rule out typical Wolf-Rayet models as the progenitor because their ejecta masses are too high and they do not fit the observed SED unless they have a massive companion which is the observed source at the supernova location. Therefore only late-time observations of the location will truly confirm if the progenitor was a helium giant and not a Wolf-Rayet star.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Northern Ireland conflict is shaped by an ethno-national contest between a minority Catholic/Nationalist/Republican population who broadly want to see the reunification of Ireland; and a majority Protestant/Unionist/Loyalist one, who mainly wish to maintain the sovereign connection with Britain. After nearly three decades of violence, which intensified segregation in schooling, labour markets and especially housing, a Peace Agreement was signed on Good Friday 1998. This paper is concerned with the peace process after the Agreement, not so much for the ambiguous political compromise, but for the way in which the city is constitutive of transformation and how Belfast in particular, is now embedded with a range of social instabilities and spatial contradictions. The Agreement encouraged rapid economic expansion, inward investment, especially in knowledge–intensive sectors and a short-lived optimism that markets and the neo-liberal fix would drive the post-conflict, post-industrial and post-political city. Capital would trump ethnicity and the economic uplift would bind citizens to a new expression of hope based on property speculation, tourism and global corporate investment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Sleep disturbances are common in critically ill patients treated in the intensive care unit (ICU) with the potential for serious consequences and long-term effects on health outcomes and patient morbidity.
Objectives Our aim was to describe sleep management and sedation practices of adult ICUs in ten countries and to evaluate roles and responsibilities of the ICU staff in relation to key sleep and sedation decisions.
Methods A multicenter, self-administered survey sent to nurse managers of adult ICUs across 10 countries. The questionnaire comprised four domains: sleep characteristics of the critically ill; sleep and sedation practices; non-pharmacological and pharmacological interventions used to improve sleep; and the autonomy and influence of nurses on sleeping practices in the ICU.
Results Overall response rate was 66% (range 32% UK to 100% Cyprus), providing data from 522 ICUs. In all countries, the most frequent patient characteristic perceived to identify sleep was lying quietly with closed eyes (N=409, 78%) (range 92% Denmark to 36% Italy). The most commonly used sedation scale was the Richmond Agitation-Sedation Score (RASS) (N=220, 42%) (range 81% UK to 0% Denmark, Cyprus where most ICUs used the Ramsay score). In most ICUs, selection of sleep medication (N=265, 51%) and assessment of effect (N=309, 59%) was performed by physicians and nurses based on collaborative discussion. In a minority of ICUs (N=161, 31%), decisions and assessments were made by physicians alone. The most commonly used (in all countries) non-pharmacological intervention to promote sleep was reducing ICU staff noise (N=473, 91%) (range 100% Denmark, Norway to 78% Canada). Only 95 ICUs (18%) used earplugs on a frequent basis (range 0% Greece, Cyprus, Denmark to 57% Sweden). Propofol was the drug used most commonly for sedation (N=359, 69%) (range 96% Sweden to 29% Canada). Chloral hydrate was used by only 63 (12%) ICUs (range 0% Greece, Cyprus, Denmark, Italy to 56% Germany). Sedation scales were used on a routine basis by 77% of the 522 ICUs. Participants scored nursing autonomy for sleep and sedation management as moderate; median score of 5 (scale of 0 to 10), range 7 (Canada, Greece, Sweden) to 4 (Norway, Poland). Nursing influence on sleep and sedation decisions was perceived considerable; median score 8, range 9 (Denmark) to 5 (Poland).
Conclusions We found considerable across country variation in sleep promotion and sedation management practices though most have adopted a sedation scale as recommended in professional society guidelines. Most ICUs in all countries used a range of pharmacological and non-pharmacological interventions to promote sleep. Most units reported inter-professional decision-making with nurses perceived to have substantial influence on sleep/sedation decisions.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Minimal residual disease (MRD) studies are useful in multiple myeloma (MM). However, the definition of the best technique and clinical utility are still unresolved issues. The aim of this study was to analyze and compare the clinical utility of MRD studies in MM with two different techniques: allelic-specific oligonucleotide real-time quantitative PCR (ASO-RQ-PCR), and flow cytometry (FCM). DESIGN AND METHODS: Bone marrow samples from 32 MM patients who had achieved complete response after transplantation were evaluated by ASO-RQ-PCR, using TaqMan technology, and multiparametric FCM. RESULTS: ASO-RQ-PCR was only applicable in 75% of patients for a variety of technical reasons, while FCM was applicable in up to 90%. Therefore, simultaneous PCR/FCM analysis was possible in only 24 patients. The number of residual tumor cells identified by both techniques was very similar (mean=0.29%, range=0.001-1.61%, correlation coefficient=0.861). However, RQ-PCR was able to detect residual myelomatous cells in 17 patients while FCM only did so in 11; thus, 6 cases were FCM negative but PCR positive, all of them displaying a very low number of clonal cells (median=0.014%, range=0.001-0.11). Using an MRD threshold of 0.01% (10(-4)) two risk groups with significantly different progression-free survival could be identified by either PCR (34 vs. 15m, p=0.04) or FCM (27 vs. 10m, p=0.05). INTERPRETATION AND CONCLUSIONS: Although MRD evaluation by ASO-RQ-PCR is slightly more sensitive and specific than FCM, it is applicable in a lower proportion of MM patients and is more time-consuming, while both techniques provide similar prognostic information.