13 resultados para questionnaire validation procedures

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aldolase has emerged as a promising molecular target for the treatment of human African trypanosomiasis. Over the last years, due to the increasing number of patients infected with Trypanosoma brucei, there is an urgent need for new drugs to treat this neglected disease. In the present study, two-dimensional fragment-based quantitative-structure activity relationship (QSAR) models were generated for a series of inhibitors of aldolase. Through the application of leave-one-out and leave-many-out cross-validation procedures, significant correlation coefficients were obtained (r(2) = 0.98 and q(2) = 0.77) as an indication of the statistical internal and external consistency of the models. The best model was employed to predict pK(i) values for a series of test set compounds, and the predicted values were in good agreement with the experimental results, showing the power of the model for untested compounds. Moreover, structure-based molecular modeling studies were performed to investigate the binding mode of the inhibitors in the active site of the parasitic target enzyme. The structural and QSAR results provided useful molecular information for the design of new aldolase inhibitors within this structural class.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Stable angina pectoris is a serious condition with few epidemiological studies in Brazil. Objective: To validate the short-version of the Rose angina questionnaire in Brazilian Portuguese for its implementation in surveys and longitudinal studies. Methods: A total of 116 consecutive patients from an outpatient clinic without prior myocardial infarction and/or coronary revascularization were enrolled for application of three questions of the Rose angina questionnaire addressing chest pain after exertion. We used the treadmill test as the gold standard with the Ellestad protocol. Results: The short-version of the Rose angina questionnaire of the 116 subjects submitted to the exercise treadmill test disclosed 89.7% of accuracy, 25% of sensitivity, 92.0% of specificity, 10.0% of positive predictive value, 97.2% of negative predictive value, and 3.1 of positive likelihood ratio and 0.82 of negative likelihood ratio. Conclusion: The Portuguese version with three items of the Rose angina questionnaire is suitable for epidemiological purposes. (Arq Bras Cardiol 2012; 99(5): 1056-1059)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este estudo teve o objetivo de construir e validar uma medida psicológica denominada de Escala de Imprevisibilidade Familiar na Infância (EIFI) para a população brasileira. Participaram 394 pessoas, sendo 158 adultos em conflito com a lei que já haviam passado pela prisão (média de idade=34,23 anos; DP=10,17), 122 estudantes universitários (M=19,26; DP=2,06) e 114 mulheres com idade superior a 40 anos e escolaridade a partir de ensino médio (M=51,19; DP=8,64). Foram conduzidos procedimentos de validade de conteúdo, face e construto. A análise fatorial gerou como produto um instrumento com estrutura de quatro dimensões (cuidado/apoio, recursos financeiros, alimentação e disciplina) com índices de confiabilidade satisfatórios para todas elas. Concluímos que a EIFI foi validada para a população brasileira apresentando-se no cenário nacional como um instrumento para medida de imprevisibilidade familiar na infância.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To validate the freezing of gait questionnaire (FOG-Q) for a Brazilian population of Parkinson's disease (PD) patients. Methods: One hundred and seven patients with a diagnosis of PD were evaluated by shortened UPDRS motor scale (sUPDRm), Hoehn and Yahr (HY), Schwab and England scale (SE), Berg balance scale (BBS), falls efficacy scale international (FES-I), gait and balance scale (GABS), and the FOG-Q Brazilian version. Results: 47.7% of PD patients had FOG episodes; this group had worse scores on sUPDRSm, FOGQ, FES-I, BBS, GABS and FOG item of UPDRS when compared to the PD group without FOG. The internal consistency was 0.86, intra-rater 0.82 and inter-rater 0.78. The FOG-Q Brazilian version was significantly correlated with items related to gait and balance. The ROC curve was 0.94, the sensitivity was 0.90 and specificity was 0.92. Conclusion: Our study suggests that the FOG-Q Brazilian version is a reliable and valid instrument for assessing FOG in PD patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The Beck Depression Inventory (BDI) is used worldwide for detecting depressive symptoms. This questionnaire has been revised (1996) to match the DSM-IV criteria for a major depressive episode. We assessed the reliability and the validity of the Brazilian Portuguese version of the BDI-II for non-clinical adults. Methods: The questionnaire was applied to 60 college students on two occasions. Afterwards, 182 community-dwelling adults completed the BDI-II, the Self-Report Questionnaire, and the K10 Scale. Trained psychiatrists performed face-to-face interviews with the respondents using the Structured Clinical Interview (SCID-I), the Montgomery-angstrom sberg Depression Scale, and the Hamilton Anxiety Scale. Descriptive analysis, signal detection analysis (Receiver Operating Characteristics), correlation analysis, and discriminant function analysis were performed to investigate the psychometric properties of the BDI-II. Results: The intraclass correlation coefficient of the BDI-II was 0.89, and the Cronbach's alpha coefficient of internal consistency was 0.93. Taking the SCID as the gold standard, the cut-off point of 10/11 was the best threshold for detecting depression, yielding a sensitivity of 70% and a specificity of 87%. The concurrent validity (a correlation of 0.63-0.93 with scales applied simultaneously) and the predictive ability of the severity level (over 65% correct classification) were acceptable. Conclusion: The BDI-II is reliable and valid for measuring depressive symptomatology among Portuguese-speaking Brazilian non-clinical populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flow around circular smooth fixed cylinder in a large range of Reynolds numbers is considered in this paper. In order to investigate this canonical case, we perform CFD calculations and apply verification & validation (V&V) procedures to draw conclusions regarding numerical error and, afterwards, assess the modeling errors and capabilities of this (U)RANS method to solve the problem. Eight Reynolds numbers between Re = 10 and Re 5 x 10(5) will be presented with, at least, four geometrically similar grids and five discretization in time for each case (when unsteady), together with strict control of iterative and round-off errors, allowing a consistent verification analysis with uncertainty estimation. Two-dimensional RANS, steady or unsteady, laminar or turbulent calculations are performed. The original 1994 k - omega SST turbulence model by Menter is used to model turbulence. The validation procedure is performed by comparing the numerical results with an extensive set of experimental results compiled from the literature. [DOI: 10.1115/1.4007571]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Method: We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results: There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p=1), and at three months (p=0.991) and six months postoperatively (p=0.985). There was no statistical difference for knee function score for all three periods (p=1.0). Conclusion: The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: To assess the performance of a food frequency questionnaire (FFQ) for estimating omega-3, omega-6 and trans fatty acid intake during pregnancy. Moreover, we determined whether the fatty acid composition of mature breast milk represents a valuable biomarker for fatty acid intake during pregnancy. SUBJECTS/METHODS: A prospective study in 41 pregnant women, aged 18-35 years, was conducted. Food intake during pregnancy was evaluated by three 24-h recalls (24 hR), and 2 FFQ. The fatty acid composition of mature breast milk was determined by gas chromatography. The method of triads and joint classification between quartiles of intake were applied. RESULTS: The FFQ was accurate for estimating docosahexanoic (DHA), linoleic and total omega-6 fatty acids according to validity coefficients. Higher agreements (>70%) into the same or adjacent quartiles between the dietary methods were found for alpha-linolenic, total omega-3, linoleic and trans fatty acid intake. High validity coefficients for eicosapentanoic (EPA) and DHA acids of human milk were found (0.61 and 0.73, respectively), and the method was adequate for categorizing the intake of alpha-linolenic, total omega-3 and trans fatty acids compared with FFQ estimates, and for arachidonic acid and trans fatty acids compared with food recall estimates, during pregnancy. CONCLUSIONS: The FFQ was an accurate tool for categorizing alpha-linolenic, total omega-3 and trans fatty acid intake. According to the validity coefficients observed, the FFQ accurately estimated DHA, linoleic and total omega-6 fatty acids and the composition of mature breast milk was shown to be a suitable biomarker for EPA and DHA fatty acid intake during pregnancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To validate the 2000 Bernstein Parsonnet (2000BP) and additive EuroSCORE (ES) to predict mortality in patients who underwent coronary bypass surgery and/or heart valve surgery at the Heart Institute, University of Sao Paulo (InCor/HC-FMUSP). Methods:A prospective observational design. We analyzed 3000 consecutive patients who underwent coronary bypass surgery and/or heart valve surgery, between May 2007 and July 2009 at the InCor/HC-FMUSP. Mortality was calculated with the 2000BP and ES models. The correlation between estimated mortality and observed mortality was validated by calibration and discrimination tests. Results: There were significant differences in the prevalence of risk factors between the study population, 2000BP and ES. Patients were stratified into five groups for 2000BP and three for the ES. In the validation of models, the ES showed good calibration (P = 0396), however, the 2000BP (P = 0.047) proved inadequate. In discrimination, the area under the ROC curve proved to be good for models, ES (0.79) and 2000BP (0.80). Conclusion: In the validation, 2000BP proved questionable and ES appropriate to predict mortality in patients who underwent coronary bypass surgery and/or heart valve surgery at the InCor/HC-FMUSP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi realizar a adaptação transcultural do Safety Attitudes Questionnaire - Short Form 2006 para o Brasil. O instrumento foi aplicado em seis hospitais de três Regiões do Brasil. Foi realizada a validade de conteúdo, face e de construto. A análise da confiabilidade do instrumento foi realizada por meio da análise da consistência interna dos itens por meio do alfa de Cronbach. A amostra do estudo foi composta por 1.301 profissionais das enfermarias clínicas e cirúrgicas de seis hospitais. A análise confirmatória mostrou que o ajuste do modelo final dos 41 itens foi considerado satisfatório. Aversão do instrumento em Português apresentou alfa de 0,89. As correlações item/total entre os domínios foram consideradas de moderada a forte, com exceção do domínio percepção do estresse. Conclui-se, portanto, que a versão do instrumento adaptada para o Português é considerada válida e confiável nesta amostra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to construct and to validate a measure of the consequences of domestic violence on women's health during climacterium. Methods: A questionnaire was administered at the Outpatient Climacterium Clinic to 124 women aged 40 to 65 years who were the victims of domestic and/or sexual violence (experimental group). They were divided into three groups: (1) those who were victims of violence exclusively during childhood/adolescence, (2) those who were victims of violence exclusively during adulthood, and (3) those who were victims of violence throughout their lives. The instrument included 34 items evaluating the beginning, frequency, and type of violence; the search for health assistance and reporting of the violence; the violence and the number of comorbidities; and violence and the Kupperman Menopausal Index. We also included a control group composed of perimenopausal and postmenopausal women who did not experience any violence (n = 120). Results: The instrument presented a Cronbach alpha = 0.82, good reliability among the examiners (+0.80), and a good possibility of reproducibility. The mean age of menopause was 45.4 years, and the mean age in the control group was 48.1 years. Group 1 showed a mean of 5.1 comorbidities, Group 2 had 4.6, and Group 3 had 4.4. Sexual violence (43.5%) and other types of violence both presented average comorbidities (4.60) but represented a significant impairment in the victim's sexual life. There were significant associations in group 3 and a high Kupperman Menopausal Index score. In the experimental group, 80.6% did not seek health services for the violence they experienced. Conclusions: The questionnaire presented good internal consistency and a validated construction. It can be easily reproduced and is indicated to evaluate the consequences of domestic and/or sexual violence on women's health during climacterium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Backgroud: It has been shown that different symptoms or symptom combinations of neuropathic pain (NeP) may correspond to different mechanistic backgrounds and respond differently to treatment. The Neuropathic Pain Symptom Inventory (NPSI) is able to detect distinct clusters of symptoms (i.e. dimensions) with a putative common mechanistic background. The present study described the psychometric validation of the Portuguese version (PV) of the NPSI. Methods: Patients were seen in two consecutive visits, three to four weeks apart. They were asked to: (i) rate their mean pain intensity in the last 24 hours on an 11-point (0-10) numerical scale; (ii) complete the PV-NPSI; (iii) provide the list of pain medications and doses currently in use. VAS and Global Impression of Change (GIC) were filled out in the second visit. Results: PV-NPSI underwent test-retest reliability, factor analysis, analysis of sensitivity to changes between both visits. The PV-NPSI was reliable in this setting, with a good intra-class correlation for all items. The factorial analysis showed that the PV-NPSI inventory assessed different components of neuropathic pain. Five different factors were found. The PV-NPSI was adequate to evaluate patients with neuropathic pain and to detect clusters of NeP symptoms. Conclusions: The psychometric properties of the PV-NPSI rendered it adequate to evaluate patients with both central and peripheral neuropathic pain syndromes and to detect clusters of NeP symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to perform a cross-cultural adaptation of the Safety Attitudes Questionnaire - Short Form 2006 for Brazil. The instrument was applied in six hospitals in three regions of Brazil. Content, face, and construct validity was performed. Analysis of the instrument's reliability was performed by verifying the items' internal consistency through Cronbach's alpha. The sample was composed of 1301 professionals working in clinical and surgical wards of six hospitals. Confirmatory analysis showed that the model including 41 items was satisfactory. The Portuguese version presented an alpha of 0.89. The item-total correlations among the domains were moderate to strong, except for the domain Stress Recognition. We concluded that the instrument's version adapted to Portuguese and applied in our sample is valid and reliable.