36 resultados para Determination of aluminium in water

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bare graphite-epoxy composite was evaluated as an electrode material in the determination of atenolol in natural water samples and pharmaceutical formulations for which the analyte was spiked. Using a DPV procedure, a linear response was observed in the 4.45-84.7 mu mol L-1 range with a LOD = 2.23 mu mol L-1, without need of surface renewal between successive runs, and recoveries between 92.5 and 107.5% for pharmaceutical formulations. The results obtained from the proposed procedure agreed with HPLC results within a 95% confidence level. During the determination of atenolol in water samples, recoveries between 96.1 and 102.6% were found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 mu mol L-1 with limit of detection of 2.80 mu mol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five-electron transfer vs. Ag vertical bar AgCl, KCl 3 M reference electrode. Very well-resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L-1 at -1.43, -1.57, -1.73, -1.88, and -2.05 V. The proposed DPV method has a good linear response in the 3.00 - 10.0 mu mol L-1 range, with a limit of detection (L.O.D) of 0.756 mu mol L-1 and 0.831 mu mol L-1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 mu mol L-1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.024207jes] All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Potassium fluorrichterite (KNaCaMg5Si8O22F2) glass-ceramics were modified by either increasing the concentration of calcium (GC5) or by the addition of P2O5 (GP2). Rods (2 x 4 mm) of stoichiometric fluorrichterite (GST), modified compositions (GC5 and GP2) and 45S5 bioglass, which was used as the reference material, were prepared using a conventional lost-wax technique. Osteoconductivity was investigated by implantation into healing defects in the midshaft of rabbit femora. Specimens were harvested at 4 and 12 weeks following implantation and tissue response was investigated using computed microtomography (mu CT) and histological analyses. The results showed greatest bone to implant contact in the 45S5 bioglass reference material at 4 and 12 weeks following implantation, however, GST, GC5 and GP2 all showed direct bone tissue contact with evidence of new bone formation and cell proliferation along the implant surface into the medullary space. There was no evidence of bone necrosis or fibrous tissue encapsulation around the test specimens. Of the modified potassium fluorrichterite compositions, GP2 showed the greatest promise as a bone substitute material due to its osteoconductive potential and superior mechanical properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amperometry coupled to flow injection analysis (FIA) and to batch injection analysis (BIA) was used for the rapid and precise quantification of ciclopirox olamine in pharmaceutical products. The favourable hydrodynamic conditions provided by both techniques allowed a very high throughput (more than 300 injections per hour) with good linear range (2.0200 mu mol L-1) and low limits of detection (below 1.0 mu mol?L-1). The results obtained were compared with titration recommended by the American Pharmacopoeia and also using capillary electrophoresis. Good agreement between all results were achieved, demonstrating the good performance of amperometry combined with FIA and BIA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polythiophene (PTh) phase electropolymerized on the stainless steel wire was evaluated as solid-phase microextraction (SPME), and analysis by liquid chromatography with spectrophotometric detection (LC-UV) for determination of new-generation antidepressants, selective serotonin reuptake inhibitors (SSRIs) (citalopram, paroxetine, fluoxetine and sertraline), in plasma samples. The influence of electropolymerization variables (scan rate, potential range and scan cycles) was evaluated on SPME performance. The SPME variables (extraction time, temperature, matrix pH, ionic strength and desorption procedure), as well as the influence of plasma proteins on sorption mechanisms were also evaluated. The SPME/LC-UV method developed for determination of antidepressants in plasma sample presented a linear range between the limit of quantification (LOQ, 200-250 ng mL(-1)) to 4000 ng mL(-1), and interday precision with coefficient of variation (CV) ranged from 11 to 15%. The proposed method can be a useful tool for the determination of antidepressants in human plasma samples in urgent toxicological analysis after the accidental or suicidal intake of higher doses of medications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phosphorus is an essential element for plants and animals, playing a fundamental role in the production of biochemical energy. Despite its relevance, phosphorus is not commonly determined by instrumental neutron activation analysis (INAA), because (32)P does not emit gamma-rays in its decay. There are alternative methods for the determination of phosphorus by INAA, such as the use of beta counting or the measurement of bremsstrahlung originated from the high energy beta particle from (32)P. Here the determination of phosphorus in plant materials by measuring the bremsstrahlung production was further investigated, to optimize an analytical protocol for minimizing interferences and overcoming the poor specificity. Eight certified reference materials of plant matrices with phosphorus ranging between 171 and 5,180 mg kg(-1) were irradiated at a thermal neutron flux of 9.5 x 10(12) cm(-2) s(-1) and measured with a HPGe detector at decay times varying from 7 to 60 days. Phosphorus solutions added to a certified reference material at three levels were used for calibration. Counts accumulated in the baseline at four different regions of the gamma-ray spectra were tested for the determination of phosphorus, with better results for the 100 keV region. The Compton scattering contribution in the selected range was discounted using an experimental peak-to-Compton factor and the net areas of all peaks in the spectra with energies higher than 218 keV, i.e. Compton edge above 100 keV. Amongst the interferences investigated, the production of (32)P from sulfur, and the contribution of Compton scattering should be considered for producing good results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Losartan is an antihypertensive agent that lost its patent protection in 2010, and, consequently, it has been available in generic form. The latter motivated the search for a rapid and precise alternative method. Here, a simple conductometric titration in aqueous medium is described for the losartan analysis in pharmaceutical formulations. The first step of the titration occurs with the protonation of losartan producing a white precipitate and resulting in a slow increase in conductivity. When the protonation stage is complete, a sharp increase in conductivity occurs which was determined to be due to the presence of excess of acid. The titrimetric method was applied to the determination of losartan in pharmaceutical products and the results are comparable with values obtained using a chromatographic method recommended by the United States Pharmacopoeia. The relative standard deviation for successive measurements of a 125 mg L-1 (2.71x10(-4) mol L-1) losartan solution was approximately 2%. Recovery study in tablet samples ranged between 99 and 102.4%. The procedure is fast, simple, and represents an attractive alternative for losartan quantification in routine analysis. In addition, it avoids organic solvents, minimizes the risk of exposure to the operator, and the waste treatment is easier compared to classical chromatographic methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple flow-injection analysis procedure was developed for determining captopril in pharmaceutical formulations employing a novel solid-phase reactor containing silver thiocyanate immobilized in a castor oil derivative polyurethane resin. The method was based on silver mercaptide formation between the captopril and Ag(I) in the solid-phase reactor. During such a reaction, the SCN- anion was released and reacted with Fe3+, which generated the FeSCN2+ complex that was continuously monitored at 480 nm. The analytical curve was linear in the captopril concentration range from 3.0 x 10(-4) mol L-1 to 1.1 x 10(-3) mol L-1 with a detection limit of 8.0 x 10(-5) mol L-1. Recoveries between 97.5% and 103% and a relative standard deviation of 2% for a solution containing 6.0 x 10(-4) mol L-1 captopril (n = 12) were obtained. The sample throughput was 40 h(-1) and the results obtained for captopril in pharmaceutical formulations using this procedure and those obtained using a pharmacopoeia procedure were in agreement at a 95% confidence level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive method using solid phase microextraction (SPME) and liquid chromatography (LC) with heated online desorption (SPME-LC) was developed and validated to analyze anticonvulsants (AEDs) in human plasma samples. A heated lab-made interface chamber was used in the desorption procedure, which allowed the transference of the whole extracted sample. The SPME conditions were optimized by applying an experimental design. Important factors are discussed such as fiber coating types, pH, extraction time and desorption conditions. The drugs were analyzed by LC, using a C18 column (150 mm x 4.6 mm x 5 mm); and 50 mmol L-1, pH 5.50 ammonium acetate buffer : acetonitrile : methanol (55 : 22 : 23 v/v) as the mobile phase with a flow rate of 0.8 mL min(-1). The suggested method presented precision (intra-assay and inter-assay), linearity and limit of quantification (LOQ) all adequate for the therapeutic drug monitoring (TDM) of AEDs in plasma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cefadroxil is a semi-synthetic first-generation oral cephalosporin used in the treatment of mild to moderate infections of the respiratory and urinary tracts, skin and soft tissue infections. In this work a simple, rapid, economic and sensitive HPLC-UV method is described for the quantitative determination of cefadroxil in human plasma samples using lamivudine as internal standard. Sample pre-treatment was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed with a mobile phase consisting of a mixture of sodium dihydrogen phosphate monohydrate solution, methanol and acetonitrile in the ratio of 90:8:2 (v/v/v) at a flow rate of 1.0mL/min. The proposed method is linear between 0.4 to 40.0 mu g/mL and its average recovery is 102.21% for cefadroxil and 97.94% for lamivudine. The method is simple, sensitive, reproducible, less time consuming for determination of cefadroxil in human plasma. The method can therefore be recommended for pharmacokinetics studies, including bioavailability and bioequivalence studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electronic polarization induced by the interaction of a reference molecule with a liquid environment is expected to affect the magnetic shielding constants. Understanding this effect using realistic theoretical models is important for proper use of nuclear magnetic resonance in molecular characterization. In this work, we consider the pyridine molecule in water as a model system to briefly investigate this aspect. Thus, Monte Carlo simulations and quantum mechanics calculations based on the B3LYP/6-311++G (d,p) are used to analyze different aspects of the solvent effects on the N-15 magnetic shielding constant of pyridine in water. This includes in special the geometry relaxation and the electronic polarization of the solute by the solvent. The polarization effect is found to be very important, but, as expected for pyridine, the geometry relaxation contribution is essentially negligible. Using an average electrostatic model of the solvent, the magnetic shielding constant is calculated as -58.7 ppm, in good agreement with the experimental value of -56.3 ppm. The explicit inclusion of hydrogen-bonded water molecules embedded in the electrostatic field of the remaining solvent molecules gives the value of -61.8 ppm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydroethanolic extracts of C. langsdorffii leaves have therapeutic potential. This work reports a validated chromatographic method for the quantification of polar compounds in the hydroethanolic extract of C. langsdorffii leaves. A reliable HPLC method was developed using two monolithic columns linked in series (100 x 4.6 mm - C-18), with nonlinear gradient elution, and UV detection set at 257 nm. A procedure for the extraction of flavonols was also developed, which involved the use of 70% aqueous ethanol and the addition of benzophenone as the internal standard. The developed method led to a good detection response as the values for linearity were between 10.3 and 1000 mu g/mL, and those for recovery between 84.2 and 111.1%. The detection limit ranged from 0.02 to 1.70 mu g/mL and the quantitation limit from 0.07 to 5.1 mu g/mL, with a maximum RSD of 5.24%. Five compounds, rutin, quercetin-3-O-alpha-L-rhamnopyranoside, kaempferol-3-O-alpha-L-rhamnopyranoside, quercetin and kaempferol, were quantified. This method could, therefore, be used for the quality control of hydroethanolic extracts of Copaifera leaves and their cosmetic and pharmaceutical products.