215 resultados para Mine fires


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mining industry presents us with a number of ideal applications for sensor based machine control because of the unstructured environment that exists within each mine. The aim of the research presented here is to increase the productivity of existing large compliant mining machines by retrofitting with enhanced sensing and control technology. The current research focusses on the automatic control of the swing motion cycle of a dragline and an automated roof bolting system. We have achieved: * closed-loop swing control of an one-tenth scale model dragline; * single degree of freedom closed-loop visual control of an electro-hydraulic manipulator in the lab developed from standard components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reviews the state-of-the-art in the automation of underground truck haulage. Past attempts at automating LHDs and haul trucks are described and their particular strengths and weaknesses are listed. We argue that the simple auto-tramming systems currently being commercialised, that follow rail-type guides placed along the back, cannot match the performance, flexibility and reliability of systems based on modern mobile robotic principles. In addition, the lack of collision detection research in the underground environment is highlighted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Draglines are used extensively for overburden stripping in Australian open cut coal mines. This paper outlines the design of a computer control system to implement an automated swing cycle on a production dragline. Subsystems and sensors have been developed to satisfy the constraints imposed by the task, the harsh operating environment and the mines production requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses some of the sensing technologies and control approaches available for guiding robot manipulators for a class of underground mining tasks including drilling jumbos, bolting arms, shotcreters or explosive chargers. Data acquired with such sensors, in the laboratory and underground, is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The purpose of this paper is to explore what the attitudes of small firm owner-managers are to developing the skills of their key resources and then examine how these and other factors affect owner-managers’ preferences for training these employees. Design/methodology/approach This study of training in small road transport firms in West Australia is cast in light of the literature on human resource management in small firms underpinned by insights drawn using the resource based view of the firm. Small firms (less than 20 people) dominate this industry, while the increasing freight task, and extreme distances between West Australian ports, towns and mines highlight this sectors’ importance. Survey results from 39 small road transport firms and interviews with nine owner-managers are analysed. Findings Legislative, regulatory and licensing requirements were shown to be a key determinant of skills development. Employers ensured that basic standards for employee certification and qualification were met, as the penalty for not doing so would be too high. Regulations drove the need for certain types of training – licenses, fatigue management, occupational health and safety, handling dangerous goods, the Maritime Security Identification Card card, forklift license, mine site inductions – while owner-managers knew where to get the training their staff needed. Although regulation appeared most visible in prescribing what happened in relation to training for drivers, the relevance of owner-managers’ attitudes could not be ignored, nor could conditions in the firms external environment as this shaped how these requirements were met. Research limitations/implications The RBV is useful in showing how skill development enabled similarity in skills across firms, while the attitudes owner-managers and economic and social conditions meant what happened in firms around skill development varied. The importance of small firm owner-managers’ attitudes are clearly highlighted and shown to influence organizational decisions and choices around training, but these were not independent of the regulatory framework and the economic and social conditions within which the firm operated. The small firms in this study did engage workers in formal training when necessary but it was put in the context of the idiosyncratic approach of the owner-manager and the day-to-day needs of the firm. “Training” was essentially about ensuring certain types of skills were held by employees and then passing on knowledge to ensure the behavior of employees was consistent with the owner-manager’s vision for the firm in its current environment. Originality/value Ways industry and government can encourage training activity that goes beyond the day-to-day firm needs are suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the mining optimisation literature, most researchers focused on two strategic-level and tactical-level open-pit mine optimisation problems, which are respectively termed ultimate pit limit (UPIT) or constrained pit limit (CPIT). However, many researchers indicate that the substantial numbers of variables and constraints in real-world instances (e.g., with 50-1000 thousand blocks) make the CPIT’s mixed integer programming (MIP) model intractable for use. Thus, it becomes a considerable challenge to solve the large scale CPIT instances without relying on exact MIP optimiser as well as the complicated MIP relaxation/decomposition methods. To take this challenge, two new graph-based algorithms based on network flow graph and conjunctive graph theory are developed by taking advantage of problem properties. The performance of our proposed algorithms is validated by testing recent large scale benchmark UPIT and CPIT instances’ datasets of MineLib in 2013. In comparison to best known results from MineLib, it is shown that the proposed algorithms outperform other CPIT solution approaches existing in the literature. The proposed graph-based algorithms leads to a more competent mine scheduling optimisation expert system because the third-party MIP optimiser is no longer indispensable and random neighbourhood search is not necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Youth misuse of fire is a substantive community concern. Despite evidence which indicates youths account for a significant proportion of all deliberately lit fires within Australia, an absence of up-to-date, contextually specific research means the exact scope and magnitude of youth misuse of fire within Australia remains unknown. Despite research suggesting com- monalities exist between youth misuse of fire and juvenile offending more broadly, misuse of fire is rarely explained using criminological theory. In light of this gap, a descriptive analysis of youth misuse of fire within New South Wales was performed. Routine Activity Theory and Crime Pattern Theory were tested to explain differences in misuse of fire across age groups. Results suggest these environmental theories offer useful frameworks for explaining youth misuse of fire in New South Wales. It is argued that the Routine Activity Theory and Crime Pattern Theory can be employed to better inform youth misuse of fire policy and prevention efforts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fire safety plays a vital role in building design because appropriate level of fire safety is important to safeguard lives and property. Cold-formed steel channel sections along with fire-resistive plasterboards are used to construct light-gauge steel frame (LSF) floor systems to provide adequate fire resistance ratings (FRR). It is common practice to use lipped channel sections (LCS) as joists in LSF floor systems, and past research has only considered such systems. This research focuses on adopting improved joist sections such as hollow flange channel (HFC) sections to improve the structural performance and FRR of cold-formed LSF floor systems under standard fire conditions. The structural and thermal performances of LSF floor systems made of a welded HFC, LiteSteel Beams (LSB), with different plasterboard and insulation configurations, were investigated using four full-scale fire tests under standard fires. These fire tests showed that the new LSF floor system with LSB joists improved the FRR in comparison to that of conventional LCS joists. Fire tests have provided valuable structural and thermal performance data of tested floor systems that included time-temperature profiles and failure times, temperatures, and modes. This paper presents the details of the fire tests conducted in this study and their results along with some important findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Objective To explore the potential for using a basic text search of routine emergency department data to identify product-related injury in infants and to compare the patterns from routine ED data and specialised injury surveillance data. - Methods Data was sourced from the Emergency Department Information System (EDIS) and the Queensland Injury Surveillance Unit (QISU) for all injured infants between 2009 and 2011. A basic text search was developed to identify the top five infant products in QISU. Sensitivity, specificity, and positive predictive value were calculated and a refined search was used with EDIS. Results were manually reviewed to assess validity. Descriptive analysis was conducted to examine patterns between datasets. - Results The basic text search for all products showed high sensitivity and specificity, and most searches showed high positive predictive value. EDIS patterns were similar to QISU patterns with strikingly similar month-of-age injury peaks, admission proportions and types of injuries. - Conclusions This study demonstrated a capacity to identify a sample of valid cases of product-related injuries for specified products using simple text searching of routine ED data. - Implications As the capacity for large datasets grows and the capability to reliably mine text improves, opportunities for expanded sources of injury surveillance data increase. This will ultimately assist stakeholders such as consumer product safety regulators and child safety advocates to appropriately target prevention initiatives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project was an initiation to investigate slaking induced properties detrition of spoil pile materials with overburden pressure and time. The changes in the material properties over time are important parameters that control the behaviour and performance of the piles. The time dependent mechanical and hydraulic properties reported together with mineralogical changes. One chamber designed to apply slaking in the laboratory and geotechnical investigation conducted to fulfil the objective of this project.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ok Tedi copper orebody consists of porphyry and skarn orebodies. The skarn orebodies, identified by different mineralogy, are the source of high intermittent fluorine levels in the mill concentrates. This paper discusses the results of the work undertaken to characterize the various fluorine-bearing minerals in samples of final copper concentrates and the distribution of fluorine amongst the minerals. Quantification of each mineral in mill feed and various flotation streams at Ok Tedi enables an understanding of the quantitative response of fluorine-bearing minerals to flotation. The metallurgical behavior of fluorine in the flotation process is also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Light gauge steel frame (LSF) wall systems are increasingly used in residential and commercial buildings as load bearing and non-load bearing elements. Conventionally, the fire resistance ratings of such building elements are determined using approximate prescriptive methods based on limited standard fire tests. However, recent studies have shown that in some instances real building fire time-temperature curves could be more severe than the standard fire curve, in terms of maximum temperature and rate of temperature rise. This has caused problems for safe evacuation and rescue activities, and in some instances has also lead to the collapse of buildings earlier than the prescribed fire resistance. Therefore a detailed research study into the performance of LSF wall systems under both standard fire and realistic fire conditions was undertaken using full scale fire tests to understand the fire performance of different LSF wall configurations. Both load bearing and non-load bearing full scale fire tests were performed on LSF walls configurations which included single layer, double layer, externally insulated wall panels made up of different steel sections and thicknesses of gypsum plasterboards. The non-load bearing fire test results were utilized to understand the factors affecting the fire resistance of LSF walls, while loading bearing fire test results led to development of simplified methods to predict the fire resistance ratings of load bearing LSF walls exposed to both standard and realistic design fires. This paper presents the results of full scale experimental study and highlights the effects of standard and realistic fire conditions on fire performance of LSF walls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an increased interest on the use of UAVs for environmental research such as tracking bush fires, volcanic eruptions, chemical accidents or pollution sources. The aim of this paper is to describe the theory and results of a bio-inspired plume tracking algorithm. A method for generating sparse plumes in a virtual environment was also developed. Results indicated the ability of the algorithms to track plumes in 2D and 3D. The system has been tested with hardware in the loop (HIL) simulations and in flight using a CO2 gas sensor mounted to a multi-rotor UAV. The UAV is controlled by the plume tracking algorithm running on the ground control station (GCS).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.