55 resultados para Mass shift

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturized analytical devices, such as heated nebulizer (HN) microchips studied in this work, are of increasing interest owing to benefits like faster operation, better performance, and lower cost relative to conventional systems. HN microchips are microfabricated devices that vaporize liquid and mix it with gas. They are used with low liquid flow rates, typically a few µL/min, and have previously been utilized as ion sources for mass spectrometry (MS). Conventional ion sources are seldom feasible at such low flow rates. In this work HN chips were developed further and new applications were introduced. First, a new method for thermal and fluidic characterization of the HN microchips was developed and used to study the chips. Thermal behavior of the chips was also studied by temperature measurements and infrared imaging. An HN chip was applied to the analysis of crude oil – an extremely complex sample – by microchip atmospheric pressure photoionization (APPI) high resolution mass spectrometry. With the chip, the sample flow rate could be reduced significantly without loss of performance and with greatly reduced contamination of the MS instrument. Thanks to its suitability to high temperature, microchip APPI provided efficient vaporization of nonvolatile compounds in crude oil. The first microchip version of sonic spray ionization (SSI) was presented. Ionization was achieved by applying only high (sonic) speed nebulizer gas to an HN microchip. SSI significantly broadens the range of analytes ionizable with the HN chips, from small stable molecules to labile biomolecules. The analytical performance of the microchip SSI source was confirmed to be acceptable. The HN microchips were also used to connect gas chromatography (GC) and capillary liquid chromatography (LC) to MS, using APPI for ionization. Microchip APPI allows efficient ionization of both polar and nonpolar compounds whereas with the most popular electrospray ionization (ESI) only polar and ionic molecules are ionized efficiently. The combination of GC with MS showed that, with HN microchips, GCs can easily be used with MS instruments designed for LC-MS. The presented analytical methods showed good performance. The first integrated LC–HN microchip was developed and presented. In a single microdevice, there were structures for a packed LC column and a heated nebulizer. Nonpolar and polar analytes were efficiently ionized by APPI. Ionization of nonpolar and polar analytes is not possible with previously presented chips for LC–MS since they rely on ESI. Preliminary quantitative performance of the new chip was evaluated and the chip was also demonstrated with optical detection. A new ambient ionization technique for mass spectrometry, desorption atmospheric pressure photoionization (DAPPI), was presented. The DAPPI technique is based on an HN microchip providing desorption of analytes from a surface. Photons from a photoionization lamp ionize the analytes via gas-phase chemical reactions, and the ions are directed into an MS. Rapid analysis of pharmaceuticals from tablets was successfully demonstrated as an application of DAPPI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present challenge in drug discovery is to synthesize new compounds efficiently in minimal time. The trend is towards carefully designed and well-characterized compound libraries because fast and effective synthesis methods easily produce thousands of new compounds. The need for rapid and reliable analysis methods is increased at the same time. Quality assessment, including the identification and purity tests, is highly important since false (negative or positive) results, for instance in tests of biological activity or determination of early-ADME parameters in vitro (the pharmacokinetic study of drug absorption, distribution, metabolism, and excretion), must be avoided. This thesis summarizes the principles of classical planar chromatographic separation combined with ultraviolet (UV) and mass spectrometric (MS) detection, and introduces powerful, rapid, easy, low-cost, and alternative tools and techniques for qualitative and quantitative analysis of small drug or drug-like molecules. High performance thin-layer chromatography (HPTLC) was introduced and evaluated for fast semi-quantitative assessment of the purity of synthesis target compounds. HPTLC methods were compared with the liquid chromatography (LC) methods. Electrospray ionization mass spectrometry (ESI MS) and atmospheric pressure matrix-assisted laser desorption/ionization MS (AP MALDI MS) were used to identify and confirm the product zones on the plate. AP MALDI MS was rapid, and easy to carry out directly on the plate without scraping. The PLC method was used to isolate target compounds from crude synthesized products and purify them for bioactivity and preliminary ADME tests. Ultra-thin-layer chromatography (UTLC) with AP MALDI MS and desorption electrospray ionization mass spectrometry (DESI MS) was introduced and studied for the first time. Because of the thinner adsorbent layer, the monolithic UTLC plate provided 10 100 times better sensitivity in MALDI analysis than did HPTLC plates. The limits of detection (LODs) down to low picomole range were demonstrated for UTLC AP MALDI and UTLC DESI MS. In a comparison of AP and vacuum MALDI MS detection for UTLC plates, desorption from the irregular surface of the plates with the combination of an external AP MALDI ion source and an ion trap instrument provided clearly less variation in mass accuracy than the vacuum MALDI time-of-flight (TOF) instrument. The performance of the two-dimensional (2D) UTLC separation with AP MALDI MS method was studied for the first time. The influence of the urine matrix on the separation and the repeatability was evaluated with benzodiazepines as model substances in human urine. The applicability of 2D UTLC AP MALDI MS was demonstrated in the detection of metabolites in an authentic urine sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poor pharmacokinetics is one of the reasons for the withdrawal of drug candidates from clinical trials. There is an urgent need for investigating in vitro ADME (absorption, distribution, metabolism and excretion) properties and recognising unsuitable drug candidates as early as possible in the drug development process. Current throughput of in vitro ADME profiling is insufficient because effective new synthesis techniques, such as drug design in silico and combinatorial synthesis, have vastly increased the number of drug candidates. Assay technologies for larger sets of compounds than are currently feasible are critically needed. The first part of this work focused on the evaluation of cocktail strategy in studies of drug permeability and metabolic stability. N-in-one liquid chromatography-tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the multiple component analysis of samples in cocktail experiments. Together, cocktail dosing and LC/MS/MS were found to form an effective tool for increasing throughput. First, cocktail dosing, i.e. the use of a mixture of many test compounds, was applied in permeability experiments with Caco-2 cell culture, which is a widely used in vitro model for small intestinal absorption. A cocktail of 7-10 reference compounds was successfully evaluated for standardization and routine testing of the performance of Caco-2 cell cultures. Secondly, cocktail strategy was used in metabolic stability studies of drugs with UGT isoenzymes, which are one of the most important phase II drug metabolizing enzymes. The study confirmed that the determination of intrinsic clearance (Clint) as a cocktail of seven substrates is possible. The LC/MS/MS methods that were developed were fast and reliable for the quantitative analysis of a heterogenous set of drugs from Caco-2 permeability experiments and the set of glucuronides from in vitro stability experiments. The performance of a new ionization technique, atmospheric pressure photoionization (APPI), was evaluated through comparison with electrospray ionization (ESI), where both techniques were used for the analysis of Caco-2 samples. Like ESI, also APPI proved to be a reliable technique for the analysis of Caco-2 samples and even more flexible than ESI because of the wider dynamic linear range. The second part of the experimental study focused on metabolite profiling. Different mass spectrometric instruments and commercially available software tools were investigated for profiling metabolites in urine and hepatocyte samples. All the instruments tested (triple quadrupole, quadrupole time-of-flight, ion trap) exhibited some good and some bad features in searching for and identifying of expected and non-expected metabolites. Although, current profiling software is helpful, it is still insufficient. Thus a time-consuming largely manual approach is still required for metabolite profiling from complex biological matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reciprocal development of the object and subject of learning. The renewal of the learning practices of front-line communities in a telecommunications company as part of the techno-economical paradigm change. Current changes in production have been seen as an indication of a shift from the techno-economical paradigm of a mass-production era to a new paradigm of the information and communication technological era. The rise of knowledge management in the late 1990s can be seen as one aspect of this paradigm shift, as knowledge creation and customer responsiveness were recognized as the prime factors in business competition. However, paradoxical conceptions concerning learning and agency have been presented in the discussion of knowledge management. One prevalent notion in the literature is that learning is based on individuals’ voluntary actions and this has now become incompatible with the growing interest in knowledge-management systems. Furthermore, commonly held view of learning as a general process that is independent of the object of learning contradicts the observation that the current need for new knowledge and new competences are caused by ongoing techno-economic changes. Even though the current view acknowledges that individuals and communities have key roles in knowledge creation, this conception defies the idea of the individuals’ and communities’ agency in developing the practices through which they learn. This research therefore presents a new theoretical interpretation of learning and agency based on Cultural-Historical Activity Theory. This approach overcomes the paradoxes in knowledge-management theory and offers means for understanding and analyzing changes in the ways of learning within work communities. This research is also an evaluation of the Competence-Laboratory method which was developed as part of the study as a special application of Developmental Work Research methodology. The research data comprises the videotaped competence-laboratory processes of four front-line work communities in a telecommunications company. The findings reported in the five articles included in this thesis are based on the analyses of this data. The new theoretical interpretation offered here is based on the assessment that the findings reported in the articles represent one of the front lines of the ongoing historical transformation of work-related learning since the research site represents one of the key industries of the new “knowledge society”. The research can be characterized as elaboration of a hypothesis concerning the development of work related learning. According to the new theoretical interpretation, the object of activity is also the object of distributed learning in work communities. The historical socialization of production has increased the number of actors involved in an activity, which has also increased the number of mutual interdependencies as well as the need for communication. Learning practices and organizational systems of learning are historically developed forms of distributed learning mediated by specific forms of division of labor, specific tools, and specific rules. However, the learning practices of the mass production era become increasingly inadequate to accommodate the conditions in the new economy. This was manifested in the front-line work communities in the research site as an aggravating contradiction between the new objects of learning and the prevailing learning practices. The constituent element of this new theoretical interpretation is the idea of a work community’s learning as part of its collaborative mastery of the developing business activity. The development of the business activity is at the same time a practical and an epistemic object for the community. This kind of changing object cannot be mastered by using learning practices designed for the stable conditions of mass production, because learning has to change along the changes in business. According to the model introduced in this thesis, the transformation of learning proceeds through specific stages: predefined learning tasks are first transformed into learning through re-conceptualizing the object of the activity and of the joint learning and then, as the new object becomes stabilized, into the creation of new kinds of learning practices to master the re-defined object of the activity. This transformation of the form of learning is realized through a stepwise expansion of the work community’s agency. To summarize, the conceptual model developed in this study sets the tool-mediated co-development of the subject and the object of learning as the theoretical starting point for developing new, second-generation knowledge management methods. Key words: knowledge management, learning practice, organizational system of learning, agency

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen kohderyhmänä oli mediatyöntekijöitä, joiden toimenkuva on viime vuosina muuttunut yhä kuormittavammaksi epäsäännöllisen vuorotyön sekä jatkuvien teknisten, organisatoristen ja taloudellisten tekijöiden ristipaineessa. Väitöskirjatutkimus on osa laajempaa tutkimushanketta, joka suunniteltiin selvittämään epäsäännöllisen vuorotyön mahdollisia haittoja. Tutkimusta tukivat taloudellisesti Työsuojelurahasto ja Suomen Hammaslääkäriseura Apollonia sekä resurssipanostuksin Hammaslääketieteen laitos (HY), Työterveyslaitos ja Yleisradio Oy. Bruksismi on tahdosta riippumatonta hampaiden narskuttelua tai yhteenpuristamista. Hampaiden narskuttelu on rytmistä jaksoittain toistuvaa puremalihasten toimintaa, joka esiintyy nukkuessa -tavallisimmin kevyen unen ja havahtumisjaksojen yhteydessä. Valveilla ollessa bruksismi on terveillä ihmisillä lähinnä hampaiden yhteenpuristamista. Yleisen käsityksen mukaan toistuvaa unibruksismia esiintyy noin 10 %:lla ja valveilla tapahtuvaa hampaiden yhteenpuristamista noin 20 %:lla. Aiemmin bruksismi kuului kansainvälisen unihäiriöluokituksen (ICSD 1997) mukaan unen erityishäiriöihin, mutta tuorein luokitus (ICSD 2005) listaa sen unen liikehäiriöihin. Väitöstutkimuksen yleisenä tavoitteena oli kartoittaa koetun bruksismin ja uni- valvehäiriöiden yhteyttä. Tutkimus oli poikittainen vertailututkimus epäsäännöllistä vuorotyötä ja säännöllisiä päivävuoroja tekevien välillä. Mielenkiinto kohdistui myös bruksismin ja kasvojen alueen kivun mahdolliseen yhteyteen. Lisäksi tutkimuksessa selvitettiin joidenkin tunnetusti unen laatua huonontavien psykososiaalisten, neurologisten ja fysiologisten tekijöiden yhteyttä koettuun bruksismiin. Tutkimuksen kohderyhmän muodosti 750 Yleisradion epäsäännöllistä vuorotyötä tekevää työntekijää. Vertailuryhmänä käytettiin samansuuruista satunnaistetusti valittua kaltaistettua Yleisradion työntekijäjoukkoa, joka tekee samankaltaista työtä, mutta säännöllisenä päivätyönä. Kohderyhmälle lähetettiin kyselylomakkeet, jotka kartoittivat koetun bruksismin lisäksi mm. tutkittavien taustatiedot, yleisen terveydentilan, yleisiä koettuja stressioireita ja tuntemuksia, kipuoireita, sekä unen laatua. Lisäksi esitettiin jaksamista ja työympäristöä koskevia kysymyksiä. Kyselyyn vastasi kaikkiaan 874 henkilöä. Kokonaisvastausprosentti oli 58,3 % (53,7 % miehiä). Epäsäännöllistä vuorotyötä tekevien vastausprosentti oli 82,3 % ja säännöllistä päivätyötä tekevien ryhmässä 34,3 %. Työtehtävät sisälsivät ohjelmien toimitus- ja tuottamistyötä, teknistä tuotanto- ja tukityötä, sekä esimies- ja hallintotyötä. Miesten keski-ikä vuorotyöryhmässä oli 45,0 (± 10,6) vuotta ja naisten keski-ikä 42,6 (± 10,7) vuotta, vastaavat luvut päivätyötä tekeville olivat 47,4 (± 9,7) ja 45,5 (± 10,1) vuotta. Vuorotyötä tekevistä oli miehiä 56,6 %, päivätyöryhmässä miehien osuus oli 46,7 %. Usein koettua bruksismia havaittiin koko tutkimusjoukossa 10,6 %:lla. Bruksismin esiintyvyydessä ei ollut merkitsevää eroa epäsäännöllistä vuorotyötä ja päivätyötä tekevien välillä. Kun bruksismia ja stressiä arvioitiin suhteessa tyytyväisyyteen nykyiseen työaikamuotoon, molemmat olivat merkitsevästi vallitsevimpia niillä, jotka halusivat vaihtaa nykyistä työaikamuotoaan. Epäsäännöllistä vuorotyötä tekevät lisäksi ilmoittivat kokevansa enemmän stressiä kuin päivätyötä tekevät sekä olivat tyytymättömämpiä työaikamuotoonsa. Tutkittavista henkilöistä katkonaista unta esiintyi 43,6 %:lla sekä 36,2 % koki unensa virkistämättömäksi. Kasvokipua esiintyi 19,6 %:lla. Usein toistuva bruksaus sekä tyytymättömyys työaikamuotoon olivat erittäin merkitsevästi yhteydessä unihäiriöiden sekä riittämättömän unen oireiden kanssa. Bruksismi ja katkonainen uni osoittautuivat myös kasvokivun taustatekijöiksi. Tutkimus osoitti, että koetulla bruksismilla oli merkitsevä yhteys unihäiriöihin, kasvokipuun, koettuun stressiin ja ahdistuneisuuteen, nuorempaan ikään, runsaampiin hammaslääkäri- ja lääkärikäynteihin sekä siihen että oli tyytymätön työaikamuotoonsa (itse työaikamuoto ei ollut merkitsevä tekijä). Tutkimuksen yhtenä johtopäätöksenä todettiin, että koettu bruksismi voi terveillä työikäisillä henkilöillä olla osa stressaavaa tilannetta ja siihen liittyvää käyttäytymistä. Tämän tiedostaminen terveydenhuollossa voisi olla hyödyllistä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A population-based early detection program for breast cancer has been in progress in Finland since 1987. According to regulations during the study period 1987-2001, free of charge mammography screening was offered every second year to women aged 50-59 years. Recently, the screening service was decided to be extended to age group 50-69. However, the scope of the program is still frequently discussed in public and information about potential impacts of mass-screening practice changes on future breast cancer burden is required. The aim of this doctoral thesis is to present methodologies for taking into account the mass-screening invitation information in breast cancer burden predictions, and to present alternative breast cancer incidence and mortality predictions up to 2012 based on scenarios of the future screening policy. The focus of this work is not on assessing the absolute efficacy but the effectiveness of mass-screening, and, by utilizing the data on invitations, on showing the estimated impacts of changes in an existing screening program on the short-term predictions. The breast cancer mortality predictions are calculated using a model that combines incidence, cause-specific and other cause survival on individual level. The screening invitation data are incorporated into modeling of breast cancer incidence and survival by dividing the program into separate components (first and subsequent rounds and years within them, breaks, and post screening period) and defining a variable that gives the component of the screening program. The incidence is modeled using a Poisson regression approach and the breast cancer survival by applying a parametric mixture cure model, where the patient population is allowed to be a combination of cured and uncured patients. The patients risk to die from other causes than breast cancer is allowed to differ from that of a corresponding general population group and to depend on age and follow-up time. As a result, the effects of separate components of the screening program on incidence, proportion of cured and the survival of the uncured are quantified. According to the predictions, the impacts of policy changes, like extending the program from age group 50-59 to 50-69, are clearly visible on incidence while the effects on mortality in age group 40-74 are minor. Extending the screening service would increase the incidence of localized breast cancers but decrease the rates of non-localized breast cancer. There were no major differences between mortality predictions yielded by alternative future scenarios of the screening policy: Any policy change would have at the most a 3.0% reduction on overall breast cancer mortality compared to continuing the current practice in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Buffer zones are vegetated strip-edges of agricultural fields along watercourses. As linear habitats in agricultural ecosystems, buffer strips dominate and play a leading ecological role in many areas. This thesis focuses on the plant species diversity of the buffer zones in a Finnish agricultural landscape. The main objective of the present study is to identify the determinants of floral species diversity in arable buffer zones from local to regional levels. This study was conducted in a watershed area of a farmland landscape of southern Finland. The study area, Lepsämänjoki, is situated in the Nurmijärvi commune 30 km to the north of Helsinki, Finland. The biotope mosaics were mapped in GIS. A total of 59 buffer zones were surveyed, of which 29 buffer strips surveyed were also sampled by plot. Firstly, two diversity components (species richness and evenness) were investigated to determine whether the relationship between the two is equal and predictable. I found no correlation between species richness and evenness. The relationship between richness and evenness is unpredictable in a small-scale human-shaped ecosystem. Ordination and correlation analyses show that richness and evenness may result from different ecological processes, and thus should be considered separately. Species richness correlated negatively with phosphorus content, and species evenness correlated negatively with the ratio of organic carbon to total nitrogen in soil. The lack of a consistent pattern in the relationship between these two components may be due to site-specific variation in resource utilization by plant species. Within-habitat configuration (width, length, and area) were investigated to determine which is more effective for predicting species richness. More species per unit area increment could be obtained from widening the buffer strip than from lengthening it. The width of the strips is an effective determinant of plant species richness. The increase in species diversity with an increase in the width of buffer strips may be due to cross-sectional habitat gradients within the linear patches. This result can serve as a reference for policy makers, and has application value in agricultural management. In the framework of metacommunity theory, I found that both mass effect(connectivity) and species sorting (resource heterogeneity) were likely to explain species composition and diversity on a local and regional scale. The local and regional processes were interactively dominated by the degree to which dispersal perturbs local communities. In the lowly and intermediately connected regions, species sorting was of primary importance to explain species diversity, while the mass effect surpassed species sorting in the highly connected region. Increasing connectivity in communities containing high habitat heterogeneity can lead to the homogenization of local communities, and consequently, to lower regional diversity, while local species richness was unrelated to the habitat connectivity. Of all species found, Anthriscus sylvestris, Phalaris arundinacea, and Phleum pretense significantly responded to connectivity, and showed high abundance in the highly connected region. We suggest that these species may play a role in switching the force from local resources to regional connectivity shaping the community structure. On the landscape context level, the different responses of local species richness and evenness to landscape context were investigated. Seven landscape structural parameters served to indicate landscape context on five scales. On all scales but the smallest scales, the Shannon-Wiener diversity of land covers (H') correlated positively with the local richness. The factor (H') showed the highest correlation coefficients in species richness on the second largest scale. The edge density of arable field was the only predictor that correlated with species evenness on all scales, which showed the highest predictive power on the second smallest scale. The different predictive power of the factors on different scales showed a scaledependent relationship between the landscape context and local plant species diversity, and indicated that different ecological processes determine species richness and evenness. The local richness of species depends on a regional process on large scales, which may relate to the regional species pool, while species evenness depends on a fine- or coarse-grained farming system, which may relate to the patch quality of the habitats of field edges near the buffer strips. My results suggested some guidelines of species diversity conservation in the agricultural ecosystem. To maintain a high level of species diversity in the strips, a high level of phosphorus in strip soil should be avoided. Widening the strips is the most effective mean to improve species richness. Habitat connectivity is not always favorable to species diversity because increasing connectivity in communities containing high habitat heterogeneity can lead to the homogenization of local communities (beta diversity) and, consequently, to lower regional diversity. Overall, a synthesis of local and regional factors emerged as the model that best explain variations in plant species diversity. The studies also suggest that the effects of determinants on species diversity have a complex relationship with scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Miniaturized mass spectrometric ionization techniques for environmental analysis and bioanalysis Novel miniaturized mass spectrometric ionization techniques based on atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were studied and evaluated in the analysis of environmental samples and biosamples. The three analytical systems investigated here were gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry (GC-µAPCI-MS) and gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry (GC-µAPPI-MS), where sample pretreatment and chromatographic separation precede ionization, and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS), where the samples are analyzed either as such or after minimal pretreatment. The gas chromatography-microchip atmospheric pressure ionization-mass spectrometry (GC-µAPI-MS) instrumentations were used in the analysis of polychlorinated biphenyls (PCBs) in negative ion mode and 2-quinolinone-derived selective androgen receptor modulators (SARMs) in positive ion mode. The analytical characteristics (i.e., limits of detection, linear ranges, and repeatabilities) of the methods were evaluated with PCB standards and SARMs in urine. All methods showed good analytical characteristics and potential for quantitative environmental analysis or bioanalysis. Desorption and ionization mechanisms in DAPPI were studied. Desorption was found to be a thermal process, with the efficiency strongly depending on thermal conductivity of the sampling surface. Probably the size and polarity of the analyte also play a role. In positive ion mode, the ionization is dependent on the ionization energy and proton affinity of the analyte and the spray solvent, while in negative ion mode the ionization mechanism is determined by the electron affinity and gas-phase acidity of the analyte and the spray solvent. DAPPI-MS was tested in the fast screening analysis of environmental, food, and forensic samples, and the results demonstrated the feasibility of DAPPI-MS for rapid screening analysis of authentic samples.