12 resultados para implant angulation

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Subretinal microphotodiode array (MPDA) is a type of visual prosthesis used for the implantation in the subretinal space of patients with progressive photoreceptor cell loss. The present study aimed to evaluate the effect of materials for MPDA on the viability, apoptosis and barrier function of cultured pig retinal pigment epithelium (RPE) cells.Methods: Primary culture of pig RPE cells was performed and 24 pig eyes were used to start RPE culture. The third passage of the cultures was plated on different materials for MPDA and MPDAs. The tetrazolium dye-reduction assay (MTT) was used to determine RPE cell viability. Flow cytometry was measured to indicate the apoptosis rates of RPE cells on different materials. RPE cells were also cultured on microporous filters, and the transepithelial resistance and permeability of the experimental molecule were measured to determine the barrier function.Results: The data from all the methods indicated no significant difference between the materials groups and the control group, and the materials tested showed good biocompatibility.Conclusions: The materials for MPDA used in the present study had no direct toxicity to the RPE cells and did not release harmful soluble factors that affected the barrier function of RPE in vitro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermally stable high-resistivity regions have been formed using hydrogen ion implantation at three energies (50, 100, and 180 keV) with three corresponding doses (6 X 10(14) 1.2 X 10(15), and 3 X 10(15) cm(-2)), oxygen implantation at 280keV with 2 X 10(14) cm(-2) as well as subsequent annealing at about 600 degrees C for 10-20s, in AlGaAs/GaAs multiple epitaxial heterojunction structure. After anncaling at 600 degrees C, the sheet resistivity increases by six orders more of magnitude from the as-grown values. This creation of high resistivity is different from that of the conventional damage induced isolation by H or O single implantation which becomes ineffective when anneal is carried out at 400-600 degrees C and the mechanism there of is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Somatic cell nuclei of giant pandas can dedifferentiate in enucleated rabbit ooplasm, and the reconstructed eggs can develop to blastocysts. In order to observe whether these interspecies cloned embryos can implant in the uterus of an animal other than th

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we investigate the effects of the indium ion implantation towards the back-channel interface on the total dose hardness of the n-channel SOI MOSFET. The results show that the indium implant has slight impact on the normal threshold voltage while preserving low leakage current after irradiation. The advantage is attributed to the narrow as-implanted and postanneal profile of the indium implantation. Two-dimensional simulations have been used to understand the physical mechanisms of the effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A subretinal implant device, Micro Photo Diode Array, which can partly imitate the function of photoreceptor cells, was presented. Process to fabricate the MPDA and characteristics of the MPDA in vivo were described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study reports a subretinal implant device which can imitate the function of photoreceptor cells. Photodiode (PD) arrays on the chip translate the incident light into current according to the intensity of light. With an electrode at the end of every photodiode, the PDs transfer the current to the remnant healthy visual cells such as bipolar cells and horizontal cells and then activate these cells. Biocompatible character of the materials and artificial photoreceptor itself were tested and the photoelectric characteristics of the chips in simulative condition were described and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work p-type Si specimens were implanted with Cl ions of 100 keV to successively increasing fluences of 1 x 10(15), 5 x 10(15), 1 x 10(16) and 5 x 10(16) ions cm(-2) and subsequently annealed at 1073 K for 30 min. The microstructure was investigated with the transmission electron microscopy (TEM) in both the plane-view and the cross-sectional view. The implanted layer was amorphized after chlorine implantation even at the lowest ion fluence, while re-crystallization of the implanted layer occurs on subsequent annealing at 1073 K. In the annealed specimens implanted above the lowest fluence three layers along depth with different microstructures were found, which include a shallow polycrystalline porous layer, a deeper single-crystalline layer containing high density of gas bubbles, a well separated deeper layer composed of dislocation loops in low density. With increasing ion fluence the thickness of the porous polycrystalline layer increases. It is indicated that chlorine can suppress the epitaxial re-crystallization of implanted silicon, when the implant fluence of Cl ions exceeds a certain level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

种质问题是养殖健康发展的基础。在鱼类养殖中,卵子和精子的质量直接关系到受精、胚胎发育,仔稚鱼发育以及幼鱼生长等一系列过程。本论文针对大西洋庸鲽和大西洋鲑的配子质量进行研究。研究内容涉及大西洋庸鲽精子冷冻保存方法;促性腺激素释放激素类似物(GnRHa)使用对其精子冷冻保存效果、以及脂肪酸组成的影响;野生和驯养大西洋鲑卵子在脂肪酸、类胡萝卜素、矿物盐方面的差异比较。 精子冷冻保存通过提高对精子的利用效率,进而对于种质改良,推进鱼类养殖科研和生产具有重要意义。本实验建立了大西洋庸鲽精子大容量冷冻保存方法。八种抗冻剂冷冻保存实验结果表明:10% 及15% DMSO配以 HBSS 或KS 的抗冻剂组合冷冻保存效果最佳,4 mL体积冷冻保存可获得与1.6 mL同样的保存效果。 在繁殖季节后期注射GnRHa激素缓释剂,可获得质量稳定的大西洋庸鲽精液,将激素注射方法与精子冷冻保存方法相结合对于提高雄鱼利用率,扩大生产规模具有重要实用价值。本项研究分三个时间采集注射GnRHa激素后的雄鱼精子以及同期未注射激素的雄鱼精子,对所有精子样品使用同样的方法进行冷冻保存,检测冷冻保存后解冻精子的受精率与活力。结果表明,激素注射与否对于冷冻保存后精子的受精率和活力无显著影响,两类冷冻精液均达到鲜精水平。实验结果还表明,注射激素14天后的精子的密度显著的降低。说明GnRHa激素的使用可以显著降低精子密度,但不会影响精子的冷冻保存效果。 本相研究同时对注射GnRHa 缓释激素和未注射GnRHa 缓释激素的大西洋庸鲽精液脂肪酸成分进行分析,以检测该激素使用对精子生化组分的影响。结果表明激素的使用对在DHA (22:6n-3,二十二碳六烯酸)、EPA(20:5n-3,二十碳五烯酸)、AA(20:4n-6,花生四烯酸)等重要脂肪酸,不饱和脂肪酸、饱和脂肪酸以及n-3、n-6等重要种类的脂肪酸总量及其比例没有显著影响。精液脂肪酸中DHA含量最高,约占25%;PUFA约为44%。 作为世界性的重要养殖品种,野生和驯养大西洋鲑在形态、生化组成以及遗传 等方面表现出的差异被广泛关注。本论文,对野生和驯养大西洋鲑受精卵关键生化成分进行分析,通过与野生受精卵比较阐明驯养受精卵的质量状况,为亲鱼营养需求提供指导依据。本实验中野生配子和驯养配子的受精率没有显著差异,但重要脂肪酸组成、类胡萝卜素以及矿物盐含量都存在多方面显著差异。两类受精卵脂肪酸中含量最高的依次为18:1n-9(油酸)、DHA(二十二碳六烯酸)、16:0(棕榈酸)、EPA(二十碳五烯酸)。野生受精卵的单不饱和脂肪酸总量显著高于驯养受精卵,而多不饱和脂肪酸(PUFA)比例显著低于驯养的受精卵。在主要必需不饱和脂肪酸(EFA)中,DHA和EPA在野生受精卵中的比例高于驯养受精卵,AA(花生四烯酸)低于驯养受精卵。野生受精卵虾青素(Ax)的含量低于驯养受精卵而鸡油菌素(Cx)含量高于驯养受精卵。野生受精卵中多种矿物盐的含量(铝、铜、铁、硒和锌)含量显著高于驯养的受精卵。差别最大的为铜。诸多方面的差异表明,野生亲鱼与驯养亲鱼产出的卵子确实存在显著差异,因此关注亲鱼的营养极为重要。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An Approach to the Rehabilitation of Prelingually Deaf Children After Cochlear Implantation Zheng Xiujin(Medical Psychology) Directed by Professor Yin WenGang Abstract Objective: To sum up the acquirement rule of speech and language capability which is for the prelingually deaf children after cochlear implantation by listening and language rehabilitation training and to investigate the factors that affect rehabilitation speed. Method: Sixty-four children received a cochlear implant at the age of 2 to 5 years from 2001 to 2005. They begin to be trained under group pattern after switch on 1 month. The whole training program lasted more than 7 months; after that, according to the teacher’s plan the training program was to be continued at home. Result: The period is 108±7.7 days that they can pronounce correctly 50 percent of all of simple-finals and compound-finals, the period is 115.0±7.8 days that they begin auditory repeating, the period is 135.3±10.9 days that they can speech the first specific word independently and the period is 200.3±13.9 days that they can speak 70 words and come into tri-gamut-word and two-word sentence period. The patient that is the group at the age of 2-3 years can take part in normal kindergarten after switch on about 10 months. There are no significant differences in various grades of speech-language development with different age groups and so do with different sex groups. There are significant differences in various grade of speech-language development with various IQ group (P<0.01) and so do with using and not using hearing aids before implantation. Conclusion: From the research we find that the speech and language development sequence is the same level between the prelingually deaf children of 2 to 5 years who received cochlear implant after speech training and normal children and which are stages of uncomplicated sound production, continuous syllabic (babbling), speech sprout, single-word utterances and two-word utterances in proper order. The time is short significantly and the reason is that cognition capability is enhanced along with the increase of age. The intelligence is main factor that affect rehabilitation speed and the speed in the group of high IQ is faster than common IQ. It is not because of the dominance cognition of the senior group that makes the increasing of the rehabilitation, it even makes slowly. The reason of which is that the senior group are exposed the language environment too late to achieve speech and language development. So we should perform an operation and training early. The effectiveness of rehabilitation after cochlear implantation is improved by using hearing aids before implantation. The reason is auditory stimulate can be benefit of to deaf children. The rehabilitation speeds in the children at the age of 2 to 5 years have nothing to do with sex. Key words: cochlear implant; speech therapy; paediatric rehabilitation