126 resultados para double gloving technique
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
于2010-11-17批量导入
Resumo:
We fabricated a bandpass filter based on Moire Bragg grating in fiber with a uniform phase mask We employed a stretch and two-exposure technique, in which the fiber was exposed to UV light from a KrF excimer through a phase mask and then the fiber is stretched and given another exposure at the same region. Due to the stretch, the periods of these two grating are slightly different, and there is a transmission between two reflection peaks at the Bragg wavelength of these two gratings.Applying different stretch can control the bandpass width of the filter. We measured the stretch characterization of a uniform Bragg grating and found the Bragg wavelength of the grating shifts linearly with the stretched length.We theoretically analyzed the grating structure and its reflection spectrum. The filter's characteristics can be optimized by choosing appropriate parameters. We will give a theoretical discussion concerning which parameters and how they affect the filter's operation.
Resumo:
The present paper describes a systematic study of argon plasmas in a bell-jar inductively coupled plasma (ICP) source over the range of pressure 5-20 mtorr and power input 0.2-0.5 kW, Experimental measurements as well as results of numerical simulations are presented. The models used in the study include the well-known global balance model (or the global model) as well as a detailed two-dimensional (2-D) fluid model of the system, The global model is able to provide reasonably accurate values for the global electron temperature and plasma density, The 2-D model provides spatial distributions of various plasma parameters that make it possible to compare with data measured in the experiments, The experimental measurements were obtained using a tuned Langmuir double-probe technique to reduce the RF interference and obtain the light versus current (I-V) characteristics of the probe. Time-averaged electron temperature and plasma density were measured for various combinations of pressure and applied RF power, The predictions of the 2-D model were found to be in good qualitative agreement with measured data, It was found that the electron temperature distribution T-e was more or less uniform in the chamber, It was also seen that the electron temperature depends primarily on pressure, but is almost independent of the power input, except in the very low-pressure regime. The plasma density goes up almost linearly with the power input.
Resumo:
The wind error of the double-edge technique Doppler lidar due to the instability of injection-seeding solid laser and the drift of interferometer s spectrum was analyzed. Corresponding numerical simulation indicated that if the wind error of 1 m/s was achieved, the unsuccessful injection-seeding pulses should be less than 0.06% in integration time of 5 min. (30000 pulses). In the respect of spectrum drift of the interferometer, double temperature control systems were used and the accuracy of minus or plus 0.002°C was obtained, corresponding to the wind error of minus or plus 0.226 m/s. Monitoring of buildup time of the injection-seeding laser and temperature of the interferometer was significantly to improve the invertion accuracy of wind error by rejecting the data with frequency jumping and drifting. Researches of injection-seeding and spectrum stability of the interferometer were practical for the development of double-edge wind lidar.}
Resumo:
Using directional freezing, Our objective was to cryopreserve rabbit semen and achieve fertility that was equal or higher than that achieved with conventional freezing. The working hypothesis was that controlling the ice-front propagation would allow redu
Resumo:
We report a new technique, called SAP, for side pumping of double-clad, rare-earth-doped fiber lasers using fiber-coupled pump sources. The highest coupling efficiency can even exceed 92% in theory with this structure.
Resumo:
Investigation of a heterogeneous electron-transfer (ET) reaction at the water/1,2-dichloroethane interface employing a double-barrel micropipet technique is reported. The chosen system was the reaction between Fe(CN)(6)(3-) in the aqueous phase (W) and ferrocene in 1,2-dichloroethane (DCE). According to the generation and the collection currents as well as collection efficiency, the ET-ion-transfer (IT) coupling process at such an interface and competing reactions with the organic supporting electrolyte in the organic phase can be studied. In addition, this technique has been found to be an efficient method to distinguish and measure the charge-transfer coupling reaction between two ions (IT-IT) processes occurring simultaneously at a liquid/liquid interface. On this basis, the formal Gibbs energies of transfer of some ions across the W/DCE interface, such as NO3-, NO2-, Cl-, COO-, TBA(+), IPAs+, Cs+, Rb+, K+, Na+, and Li+, for which their direct transfers are usually difficult to obtain because of the IT-IT coupling processes, were quantitatively evaluated.
Resumo:
Because of high efficiencies, compact structure, and excellent heat dissipation, high-power fiber lasers are extremely useful for applications such as cutting, welding, precision drilling, trimming, sensing, optical transmitter, material processing, micromachining, and so on. However, the wavefront of the double clad fiber laser doped with ytterbium is still unknown. In this paper, wavefront of a fiber laser is measured and the traditional Hartmann-shack wavefront sensing method is adopted. We measured a double clad fiber laser doped with ytterbium which produces pulse wave output at infrared wavelength. The wavefront shape and contour are reconstructed and the result shows that wavefront is slightly focused and not an ideal plane wavefront. Wavefront measurement of fiber laser will be useful to improving the lasers' performance and developing the coherent technique for its applications.
Resumo:
Doubled femtosecond laser pulses in-line are needed in the collinear pump-probe technique, collinear second harmonic generation frequency-resolved optical gating (SHG FROG) and the spectral phase interferometry for direct electric-field reconstruction (SPIDER), etc. Normally, it is generated by using a Michelson's structure. In this paper, we proposed a novel structure with two-layered reflective Dammann gratings and the reflective mirrors to generate doubled femtosecond laser pulses in line without transmission optical elements. Angular dispersion and spectral spatial walk-off are both compensated. In addition, this structure can also compress the positive chirped pulse, which cannot be realized with a Michelson's structure. By adopting triangular grating and blazed gratings, the efficiency of the system would in principle be increased as the Michelson's scheme. Experiments demonstrated that this method should be an alternative approach for generation of the double compressed pulses of femtosecond laser for practical applications. (c) 2006 Elsevier GmbH. All rights reserved.
Resumo:
In plants and less-advanced animal species, such as C.elegans, introduction of exogenous double-stranded RNA (dsRNA) into cells would trigger degradation of the mRNA with homologous sequence and interfere with the endogenous gene expression. It might represent an ancient anti-virus response which could prevent the mutation in the genome that was caused by virus infection or mobile DNA elements insertion. This phenomenon was named RNA interference, or RNAi. In this study, RNAi was used to investigate the function of basonuclin gene during oogenesis. Microinjection of dsRNA directed towards basonuclin into mouse germinal-vesicle-intact (GV) oocytes brought down the abundance of the cognate mRNA effectively in a time- and concentration-dependent manner. This reduction effect was sequence-specific and showed no negative effect on other non-homologous gene expression in oocytes, which indicated that dsRNA can recognize and cause the degradation of the transcriptional products of endogenous basonuclin gene in a sequence-specific manner. Immunofluorescence results showed that RNAi could reduce the concentration of basonuclin protein to some extent, but the effect was less efficient than the dsRNA targeting towards tPA and cMos which was also expressed in oocytes. This result might be due to the long half life of basonuclin protein in oocytes and the short reaction time which was posed by the limited life span of GV oocytes cultured in vitro. In summary, dsRNA could inhibit the expression of the cognate gene in oocytes at both mRNA and protein levels. The effect was similar to Knock-out technique which was based on homologous recombination. Furthermore, hairpin-style dsRNA targeting basonuclin gene could be produced by transcription from a recombinant plasmid and worked efficiently to deplete the cognate mRNA in oocytes. This finding offered a new way to study the function of basonuclin in the early stage of oogenesis by infection of primordial oocytes with the plasmid expressing hairpin-style basonuclin dsRNA.
Resumo:
The transmiss on time and tunneling probability of an electron through a double quantum dot are studied using the transfer matrix technique. The time-dependent Schrodinger equation is applied for a Gaussian wave packet passing through the double quantum clot. The numerical calculations are carried out for a double quantum clot consisting of GaAs/InAs material. We find that the electron tunneling resonance peaks split when the electron transmits through the double quantum dot. The splitting energy increases as the distance between the two quantum dots decreases. The transmission time can be elicited from the temporal evolution of the Gaussian wave packet in the double quantum dot. The transmission time increases quickly as the thickness of tire barrier increases. The lifetime of the resonance state is calculated tram the temporal evolution of the Gaussian-state at the centers of quantum dots.
Resumo:
We report the technique of the ion-implanted semi-insulating GaAs wafer used for passive Q-switched mode locking in double-cladding Yb:fiber laser. The wafer was implanted with 400-keV energy, 10(16)/cm(2) dose As+ ions, and was annealed at 600degreesC for 20 min. At the pump power of 5W, we achieved output power of 200mW. The repetition rate of envelope of Q-switched mode locking is 50-kHz with a FWHM envelope of 4mus. The repetition rate of mode locked pulse train was found to be 15-MHz. This is the first report of such a kind of laser to the best of our knowledge.
Resumo:
The ground states and degree of entanglement of double hydrogenic impurities in a pair of vertically stacked InGaAs/GaAs quantum dots are studied with a proposed diagonalization technique. It is found that at short barrier widths, the entanglement is small due to the coupling between the intra- and interdot orbitals. At large barrier widths, large entanglement occurs.
Resumo:
Semiconducting gadolinium silicide GdxSi samples were prepared by mass-analyzed low-energy dual ion beam epitaxy technique. Auger electron spectroscopy depth profiles indicate that the gadolinium ions are implanted into the single-crystal silicon substrate and formed 20 nm thick GdxSi film. X-ray double-crystal diffraction measurement shows that there is no new phase formed. The XPS spectra show that one type of silicon peaks whose binding energy is between that of silicide and silicon dioxide, and the gadolinium peak of binding energy is between that of metal Gd and Gd2O3. All of these results indicate that an amorphous semiconductor is formed. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
A model for analyzing point defects in compound crystals was improved. Based on this modified model, a method for measuring Mn content in GaMnAs was established. A technique for eliminating the zero-drift-error was also established in the experiments of X-ray diffraction. With these methods, the Mn content in GaMnAs single crystals fabricated by the ion-beam epitaxy system was analyzed.