75 resultados para Spectral Line Broadening (Slb) Model
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
A semi-gas kinetics (SGK) model for performance analyses of flowing chemical oxygen-iodine laser (COIL) is presented. In this model, the oxygen-iodine reaction gas flow is treated as a continuous medium, and the effect of thermal motions of particles of different laser energy levels on the performances of the COIL is included and the velocity distribution function equations are solved by using the double-parameter perturbational method. For a premixed flow, effects of different chemical reaction systems, different gain saturation models and temperature, pressure, yield of excited oxygen, iodine concentration and frequency-shift on the performances of the COIL are computed, and the calculated output power agrees well with the experimental data. The results indicate that the power extraction of the SGK model considering 21 reactions is close to those when only the reversible pumping reaction is considered, while different gain saturation models and adjustable parameters greatly affect the output power, the optimal threshold gain range, and the length of power extraction.
Resumo:
The effect of the translational nonequilibrium on performance modeling of flowing chemical oxygen-iodine lasers (COIL) is emphasized in this paper. The spectral line broadening (SLB) model is a basic factor for predicting the performances of flowing COIL. The Voigt profile function is a well-known SLB model and is usually utilized. In the case of gas pressure in laser cavity less than 5 torr, a low pressure limit expression of the Voigt profile function is used. These two SLB models imply that ail lasing particles can interact with monochromatic laser radiation. Basically, the inhomogeneous broadening effects are not considered in these two SLB models and they cannot predict the spectral content. The latter requires consideration of finite translational relaxation rate. Unfortunately, it is rather difficult to solve simultaneously the Navier-Stokes (NS) equations and the conservation equations of the number of lasing particles per unit volume and per unit frequency interval. In the operating condition of flowing COIL, it is possible to obtain a perturbational solution of the conservational equations for lasing particles and deduce a new relation between the gain and the optical intensity, i.e., a new gain-saturation relation. By coupling the gain-saturation relation with other governing equations (such as the NS equations, chemical reaction equations and the optical model of gain-equal-loss), We have numerically calculated the performances of flowing COIL. The present results are compared with those obtained by the common rate-equation (RE) model, in which the Voigt profile function and its low pressure limit expression are used. The difference of different model's results is great. For instance, in the case of lasing frequency coinciding with the central frequency of line profile and very low gas pressure, the gain-saturation relation of the present model is quite different with that of the RE model.
Resumo:
phases should be specified when the particle Reynolds number is higher than
Resumo:
This paper investigates the absorptive spectral lines of four-level atomic system driven by a coupling, probe and microwave fields. Due to the perturbation of the microwave field, the original electromagnetically induced transparency is changed to electromagnetically induced absorption and the absorptive spectral line can be very narrow. This ultranarrow spectral line has potential applications to the microwave atomic frequency standard and the measurement of very weak magnetic field.
Resumo:
Strong laser-field-induced autoionisation in the presence of both photoionising and radiative decay of the autoionising state (AS) is investigated, focusing on the laser intensity dependence of the photoemission and photoelectron spectra. In contrast to previous predictions, power broadening and increasing reduction of the doublet peak heights with field strength are found in the photoemission spectrum. Similar effects leading to considerable suppression and even complete disappearance of the lowest-order peaks in the photoelectron spectrum, together with peak switching, are also demonstrated, which are closely related to above-threshold ionisation. In addition, it is suggested that the total number of energetic photoelectrons may serve as an alternative to measuring the atomic parameters of the AS. All these effects are attributed to the presence of the strong `probe': laser-induced decay of the AS.
Resumo:
A constrained high-order statistical algorithm is proposed to blindly deconvolute the measured spectral data and estimate the response function of the instruments simultaneously. In this algorithm, no prior-knowledge is necessary except a proper length of the unit-impulse response. This length can be easily set to be the width of the narrowest spectral line by observing the measured data. The feasibility of this method has been demonstrated experimentally by the measured Raman and absorption spectral data.
Resumo:
We investigate the fluorescence spectrum in a nearly degenerate atomic system of a F-e = 0 -> F-g = 1 transition by analytically solving Schrodinger equations. An ultranarrow fluorescence spectral line in between the two coherent population trapping windows has been found. Our analytic solutions clearly show the origin of the ultranarrow spectral line. Due to quantum interference effects between two coherent population trapping states, the width and intensity of the central spectral line can be controlled by an external magnetic field. Such an effect may be used to detect a magnetic field.
Resumo:
Based on the 2 x 2 (electric field) cross-spectral density matrix, a model for an electromagnetic J(0)-correlated Schell-model beam is given that is a generalization of the scalar J(0)-correlated Schell-model beam. The conditions that the matrix for the source to generate an electromagnetic J(0)-correlated Schell-model beam are obtained. The condition for the source to generate a scalar J(0)-correlated Schell-model beam can be considered as a special case. (C) 2008 Optical Society of America
Resumo:
A single longitudinal mode and narrow line width external cavity semiconductor laser is proposed. It is constructed with a semiconductor laser, collimator, a flame grating, and current and temperature control systems. The one facet of semiconductor laser is covered by high transmission film, and another is covered by high reflection film. The flame grating is used as light feedback element to select the mode of the semiconductor laser. The temperature of the constructed external cavity semiconductor laser is stabilized in order of 10(-3)degreesC by temperature control system. The experiments have been carried out and the results obtained-the spectral fine width of this laser is compressed to be less than 1.4MHz from its original line-width of more than 1200GHz and the output stability (including power and mode) is remarkably enhanced.
Resumo:
采用离子球模型,通过自治求解Poisson方程和Dirac方程,得到氖的类氢离子低能级组态的能级能量随等离子体电子温度和电子密度的变化关系,进一步研究了等离子体电子温度和电子密度对光谱漂移的影响。结果表明:光谱漂移随着等离子体电子密度的增大而增大,随着电子温度的升高而减小;谱线精细结构分裂随着电子密度的增大而减小.随着电子温度的升高而增大。等离子体对束缚电子的屏蔽是决定光谱漂移的主要原因。这些变化规律不仅对等离子体光谱模拟结果产生影响,而且使实验上观测光谱的相对或绝对漂移成为可能.从而为高密度等离子体诊断
Resumo:
Polybrominated diphenyl ethers (PBDEs) are an important class of halogenated organic brominated flame retardants. Because of their presence in abiotic and biotic environments widely and their structural similarity to polychlorinated biphenyls (PCBs), concern has been raised on their possible adverse health effects to humans. This study was designed to determine the anti-proliferative, apoptotic properties of decabrominated diphenyl ether (PBDE-209), using a human hepatoma Hep G2 line as a model system. Hep G2 cells were cultured in the presence of PBDE-209 at various concentrations (1.0-100.0 mu mol/L) for 72 h and the percentage of cell viability was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay. The results showed that PBDE-209 inhibited the cells viability in time and concentration-dependent characteristics at concentrations (10.0-100.0 mu mol/L). We found that anti-proliferative effect of PBDE-209 was associated with apoptosis on Hep G2 cells by determinations of morphological changes, cell cycle and apoptosis. Mechanism study showed that PBDE-209 could increase the generation of intracellular reactive oxygen species (ROS) concentration-dependently. Antioxidant N-acetylcyteine partially inhibited the increase of ROS. The mechanism for its hepatoma-inhibitory effects was the induction of cellular apoptosis through ROS generation. In addition, activity of lactate dehydrogenase (LDH) release increased when the cells incubated with PBDE-209 at various concentrations and times. These results suggested that PBDE-209 had the toxicity activity of anti-proliferation and induction of apoptosis in tumor cells in vitro. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The H4IIE rat hepatoma cell line was employed as a cell model to screen 7-ethoxyresorufin O-deethylase (EROD)-TCDD equivalents (EROD-TEQ) of human breast milk samples collected from Hong Kong and Guangzhou, China. The screening methods employed a 96-well plate spectrofluorometer-EROD assay. For cell-line validation, our results demonstrated a dose-dependent increase in the Ah receptor-mediated response (i.e., CYP1A1 mRNA and EROD) of the cells upon exposure to a number of known Ah receptor agonists, including 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), 2,3,7,8-tetrachlorodibenzothiophene, benzo[a]pyrene, and beta-naphthaflavone. TCDD induced CYP1A1 mRNA and EROD was in a close positive correlation (r = 0.98). For the screening of dioxin-like compounds, breast milk samples collected during lactation weeks 3-5 were used. One hundred (from Hong Kong) and 48 (from Guangzhou) breast milk samples were assayed, of which 65% and 68% of the samples, respectively, showed detectable dioxin-like activities using the H4IIE cell EROD screening method. For sixty-five samples from Hong Kong the mean EROD-TEQ values ranged from 58.1 to 96.5 pg/g of milk fat for those aged 21-36 years while 32 samples from Guangzhou had mean values of 98.8-202.1 pg/g of milk fat. In comparisons of the EROD-TEQ values for different age groups from both cities, there were no significant differences (P < 0.05). However, the mean and median EROD-TEQ values of the Guangzhou population were in general higher than those of the Hong Kong population. The results of the present study indicate that it is feasible to use the H4IIE cell-line as a model for screening dioxin-like compounds in human breast milk. In addition, the method is rapid and cost-effective, particularly for a routine and high-throughput sample screening analysis, compared to the costly and time-intensive chemical analytical techniques. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
Major State Basic Research Project 973 program of China 2006CB604907;National Science Foundation of China 60776015 60976008;863 High Technology R&D Program of China 2007AA03Z402
Resumo:
Based on the semiconductor laser whose spectral line with width is compressed to be less than 1.2Mhz, a system was designed to measure and improve the amplitude and frequency of the real-time microvibration with sinusoidal modulation. real-time microvibration measurement was executed without alignment problem in the interferometry; and low-frequency disturbance of environment could be eliminated. Suggestions were also given to consummate the system. The system also has resistance against the low frequency disturbance of the environment.
Resumo:
Plasmon resonance spectra of supported Ag nanoparticles are studied by depositing the particles on different substrates. It was found that the dielectric properties of the substrates have significant effects on the spectral line shape, except the resonance frequency. Beyond the plasmon resonance band, the spectral shape is mainly governed by the dielectric function, particularly its imaginary part, of the substrate. The plasmon resonance band, on the other hand, may be severely distorted if the substrate is absorbing strongly.