50 resultados para Automatic Calibration
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
A material model, whose framework is parallel spring-bundles oriented in 3-D space, is proposed. Based on a discussion of the discrete schemes and optimum discretization of the solid angles, a 3-D network cell consisted of one-dimensional components is developed with its geometrical and physical parameters calibrated. It is proved that the 3-D network model is able to exactly simulate materials with arbitrary Poisson ratio from 0 to 1/2, breaking through the limit that the previous models in the literature are only suitable for materials with Poisson ratio from 0 to 1/3. A simplified model is also proposed to realize high computation accuracy within low computation cost. Examples demonstrate that the 3-D network model has particular superiority in the simulation of short-fiber reinforced composites.
A new expression of hardening coefficients for fcc-crystal and calibration of the material constants
Resumo:
In order to describe the effect of latent hardening on the macro-plastic behavior of foc-crystal, a new expression for hardening coefficient is proposed in which there are 12 material constants, each having clear physical meaning. And a method of material constant calibration is suggested and used to determine the material constants of copper and aluminum crystal. The simulated load-elongation curves along various crystallographic orientations are comparable with the experimental ones.
Resumo:
The concept of biosensor with imaging ellipsometry was proposed about ten years ago. It has become an automatic analysis technique for protein detection with merits of label-free, multi-protein analysis, and real-time analysis for protein interaction process, etc. Its principle, andrelated technique units, such as micro-array, micro-fluidic and bio-molecule interaction cell, sampling unit and calibration for quantitative detection as well as its applications in biomedicine field are presented here.
Resumo:
In order to characterize the physical and spatial properties of nano-film pattern on solid substrates, an automatic imaging spectroscopic ellipsometer (ISE) based on a polarizer - compensator - specimen - analyzer configuration in the visible region is presented. It can provide the spectroscopic ellipsometric parameters psi (x, y, lambda) and Delta (x, y, lambda) of a large area specimen with a lateral resolution in the order of some microns. A SiO2 stepped layers pattern is used to demonstrate the function of the ISE which shows potential application in thin film devices' such as high-throughput bio-chips.
Resumo:
We propose an optical apparatus enabling the measurement of spherical power, cylindrical power, and optical center coordinates of ophthalmic lenses. The main advantage of this new focimeter is to provide a full bidimensional mapping of the characteristics of ophthalmic glasses. This is made possible thanks to the use of a large-area and high-resolution position-sensitive detector. We describe the measurement principle and present some typical mappings, particularly for progressive lenses. We then discuss the advantages in terms of speed and versatility of such a focimeter for the measurement of complex lens mappings. (C) 2002 Optical Society of America.
Resumo:
A novel phase-step calibration technique is presented on the basis of a two-run-times-two-frame phase-shift method. First the symmetry factor M is defined to describe the distribution property of the distorted phase due to phase-shifter miscalibration; then the phase-step calibration technique, in which two sets of two interferograms with a straight fringe pattern are recorded and the phase step is obtained by calculating M of the wrapped phase map, is developed. With this technique, a good mirror is required, but no uniform illumination is needed and no complex mathematical operation is involved. This technique can be carried out in situ and is applicable to any phase shifter, whether linear or nonlinear. (c) 2006 Optical Society of America.
Resumo:
A laser beam automatic alignment system is applied in a multipass amplifier of the SG-III prototype laser. Considering the requirements of the SG-III prototype facility, by combining the general techniques of the laser beam automatic alignment system, according to the image relayed of the pinholes in the spatial filter, and utilizing the optical position and the spatial distribution of the four pinholes of the main spatial filter in the multipass amplifier of the SG-III prototype, a reasonable and optimized scheme for automatic aligning multipass beam paths is presented. It is demonstrated on the multipass amplifier experimental system. (C) 2004 Society of Photo-Optical Instrumentation Engineers.
Resumo:
A new calibration method for a photoelastic modulator is proposed. The calibration includes a coarse calibration and a fine calibration. In the coarse calibration, the peak retardation of the photoelastic modulator is set near 1.841 rad. In the fine calibration, the value of the zeroth Bessel function is obtained. The zeroth Bessel function is approximated as a linear equation to directly calculate the peak retardation. In experiments, the usefulness of the calibration method is verified and the calibration error is less than 0.014 rad. The calibration is immune to the intensity fluctuation of the light source and independent of the circuit parameters. The method specially suits the calibration of a photoelastic modulator with a peak retardation of less than a half-wavelength. (c) 2007 Optical Society of America.
Resumo:
Although long chain alkenones (LCKs) occur widely in lacustrine sediments, their origin is not clear. Here, we report a lacustrine source, the non-calcifying species Chrysotila lamellosa Anand (Haptophyceae), collected and isolated from an inland saline water body, Lake Xiarinur (Inner Mongolia, China). Its alketione pattern is similar to those of coastal marine strains of C lamellosa,but the relationship between U-37(K') index and culture temperature for the lacustrine species is quite different from that of the coastal species. A significant feature of the alkenones in this strain of C lamellosa is a lack of C-38 methyl alkenones, which might be used to distinguish the species from the marine haptophyte species Emiliania huxleyi and Gephyrocapsa oceanica. The higher C-38 tetraunsaturated compound abundance might be another important feature for distinguishing the C lamellosa alkenone producer from the coastal species Isochrysis galbana. This alkenone distribution pattern has been detected in many lakes, which suggests that C lamellosa or a closely related species might be a very common alkenone precursor in lacustrine systems. We examined U-37(K') and U-37(K) values for C lamellosa as a function of culture temperature in a batch culture experiment. The calibration for U-37(K') vs. culture temperature (T) was U-37(K') = 0.0011 x T-2 - 0.0157 x T + 0.1057(n = 14, r(2) = 0.99) from 10 degrees C to 22 degrees C or U-37(K') = 0.0257 x T - 0.2608(n = 9, r(2) = 0.97) from 14 degrees C to 22 degrees C. U-37(K) vs. culture temperature was U-37(K) = 0 0377 x T - 0.5992(n = 14, r(2) = 0.98) from 10 degrees C to 22 degrees C. Our experiments show that the alkenone unsaturation index (U-37(K')) is strongly controlled by culture temperature and can be used for palaeoclimate reconstruction. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The error theory of linear equation system has been applied to the calibration procedure of microwave network analyser in this article. A new explanation for the choice of the linear calibration equations is proposed and a general principle for choosing calibration equations is presented. The method can also be used to predict the occurrence of the problem of frequency limitation at some periodic frequencies. This principle is employed to the thru-short-delay (TSD) method and the solution using the chosen equations gives the most accurate results. A good agreement between the theory and the experiment has been obtained.
Resumo:
Correct classification of different metabolic cycle stages to identification cell cycle is significant in both human development and clinical diagnostics. However, it has no perfect method has been reached in classification of metabolic cycle yet. This paper exploringly puts forward an automatic classification method of metabolic cycle based on Biomimetic pattern recognition (BPR). As to the three phases of yeast metabolic cycle, the correct classification rate reaches 90%, 100% and 100% respectively.
Resumo:
This paper presents a systematic description of the methods for calibrating microwave network analyzer and test fixtures, and discusses the problems arising in the calibration. The general criteria for choosing calibration standards and corresponding algorithms are discussed and suggestions to overcome these problems and improve the calibration accuracy are also given. It has been found that for reciprocal test fixtures, the four equations obtained with the thru standard can be used at the same time. Meanwhile, the calibration accuracy can be improved. It has been shown that using the same calibration procedures but different algorithms may lead to the occurrence of frequency limitation.
Resumo:
At least three known standards are normally required for the full two-port test fixture calibration in vector network analyzers (VNA). In this paper, a calibration procedure using only one standard, based on establishing two hypothetical symmetrical fixtures using triple-through method, is shown. The results using the calibrating method to subtract the influence of fixtures are in accord with the directly measured data of the device-under-test (DUT) without the fixtures very well, which shows that the proposed method is very simple and accurate.
Resumo:
Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.