35 resultados para Aspheric collimating lens

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

在传统哈特曼检验法基础上研制成功一种扫描型哈特曼检测新装置。可对最大口径为Ф300mm的聚焦镜在全口径范围内进行采样测量。该检测装置由大口径标准平行光管、扫描式哈特曼光阑、被俭聚焦镜、CCD摄像机及计算机组成。在水平和垂直两个径向上开有等间距排列且相互错开半个间距的小孔。并且在步进电机的驱动下绕光轴旋转。可对被检聚焦镜进行全口径连续采样。对有效口径为夺154mm的斐索平面干涉仪非球面准直物镜的球差及焦斑能量集中度进行了测量。进而由球差计算得到了波像差。并用干涉法对该准直物镜进行了测量。球差的理论值与测量值

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The encircled energy of a focusing lens is one of the parameters directly affecting the target efficiency in high-power laser facilities. The direct measurement method of the encircled energy for the focusing lens based on the scanning Hartmann test is proposed in this paper. With the scanning Hartmann test setup, the information in the whole aperture of the focusing lens can be achieved. The encircled energy can be obtained by analyzing the spot diagram on the focal plane of the focusing lens. In experiments, the encircled energy of an aspheric focusing lens is measured using this method. The measurement result is in good agreement with that derived from measurement data by an interferometer and the difference is 7.7%. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

提出了一种利用扫描型哈特曼检测装置检验靶镜光学质量的技术.该装置对传统哈特曼检验装置的光阑进行了改进,通过扫描型哈特曼光阑的旋转扫描,可对被检靶镜全口径范围内连续采样.利用该扫描型哈特曼检测装置对一块口径为φ270 mm的非球面靶镜的能量集中度和波像差进行了检验,其结果与激光数字波面干涉仪的测量结果相吻合,其中能量集中度的相对测量误差为7.7%,波像差的相对测量误差为10.2%,验证了该检测技术的有效性.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to design and fabricate a spectrometer for the infrared range widely used in the different applications, Volume Phase Grating (VPG) with. low Polarization Dependence Loss (PDL) and high efficiency has been adopted as the dispersion element. VPG is constructed by coating an optical substrate with a thin film of dichromated. gelatin and exposing the film to two mutually coherent laser beams to form index modulation. The diffraction efficiency for a VPG is governed by Bragg effects. The depth (d) and index modulation contrast of the grating structure control the efficiency at which the light is diffracted when the Bragg condition is satisfied. Gradient index lens with high performance and low aberration are used as collimating system instead of standard lens. The spot diagrams and MTF curve of the collimating lens are shown in the paper. The receive system is InCaAs photodiode (PD) array including 512 pixels with 25 mum pitch. The spectrum resolution of the spectrometer reaches to 0.2nm and wavelength accuracy is 40pm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

设计了一个激光光斑实时监测与光路自动准直装置,能够实时监测激光光斑并自动准直激光输出方向。基于透镜成像原理,使用CCD探测器获得光斑的二维成像,并根据两点确定一条直线原理和使用压电陶瓷电动调整架实现光路自动准直;监测控制程序采用虚拟仪器开发软件Lab View编写,可以实时监测激光光斑模式与光斑位置抖动情况,并进行反馈控制。经测试,设计装置的调整精度达0.5μrad,反馈控制频率约1 Hz,完全可降低或消除抖动周期在1 s以上的光斑飘移。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

用体布拉格光栅(VBG)作为反馈元件与瓦级半导体激光器(LD)以及快轴准直柱透镜构成一个可以将半导体激光器的工作波长稳定在体布拉格光栅布拉格波长处的外腔激光器。测量了体布拉格光栅外腔激光器的波长稳定性与其工作电流、热汇温度、激光束准直装置等因素的关系。分析了波长稳定效果与半导体激光器增益谱特性、外腔结构参量等因素的关系。研究表明,在相同的工作电流、热汇温度下,当准直柱透镜直径为0.4 mm时的波长稳定效果较好;在此情况下,当热汇温度控制在30 ℃,工作电流从0.5 A增加到1.5 A的测量范围内,以及当工

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previously suggested birefringence-customized modular optical interconnect technique is extended for lens-free relay operation. Various lens-free relay imaging models are developed. We claim that the lens-free relay system is important in simplifying an optical interconnect system whenever the imaging conditions permit. To verify the validity of various proposed concepts, we experimentally implemented some 8 x 8 optical permutation modules. High-power efficiency and low channel cross talk were experimentally observed. In general, the larger the channel spacing, the less the cross talk. A quantitative cross-talk measurement of the lens-free relay system shows that, for a fixed channel width of 0.5 mm and channel spacings of 0.5, 1, and 2 mm, a less than -20-dB cross-talk performance can be guaranteed for lens-free relay distances of 40, 280, and 430 mm, respectively. (C) 1998 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme using a lens array and the technique of spectral dispersion is presented to improve target illumination uniformity in laser produced plasmas. Detailed two-dimensional simulation shows that a quasi-near-field target pattern, of steeper edges and without side lobes, is achieved with a lens array, while interference stripes inside the pattern are smoothed out by the use of the spectral dispersion technique. Moving the target slightly from the exact focal plane of the principal focusing lens can eliminate middle-scale-length intensity fluctuation further. Numerical results indicate that a well-irradiated laser spot with small nonuniformity and great energy efficiency can be obtained in this scheme. (c) 2007 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme of combining technology of lens array (LA) and smoothing by spectral dispersion (SSD) is introduced to improve the irradiation uniformity in laser fusion based on the earlier works on LA. The feasibility of the scheme is also analyzed by numerical simulation. It shows that a focal pattern with flat-top and sharp-edge profile could be obtained, and the irradiation nonuniformity can fall down from 14% with only LA to 3% with both SSD and LA. And this smoothing scheme is depended less on the incidence comparing to other smoothing methods. The preliminary experiment has demonstrated its effectiveness. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lens array composed of edge-softened elements is used to improve on-target irradiation uniformity in the Shenguang II Laser Facility, with which a Fresnel pattern of suppressed diffraction peaks is obtained. Additional uniformity can be reached by reducing short-wavelength interference speckles inside the pattern when the technique of smoothing by spectral dispersion is also used. Two-dimensional performance of irradiation is simulated and the results indicate that a pattern of steeper edges and a flat top can be achieved with this joint technique. (c) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the interferential theory, we deduce a new type of analytic expression suitable for describing the evolutions of the optical bottle beam generated from the axicon-lens optical system illuminated by the Gaussian beam for the first time. The theory does not use much approximation in the process of mathematical analysis and can better illustrate the optical bottle beam evolutions at any positions. With the derived expression, the three-dimensional (3D) longitudinal and transverse intensity profiles of the optical bottle beam are simulated numerically. The numerical calculations have been confirmed by the experimental results.