103 resultados para EXTERNAL LOAD
Resumo:
An extension of Faulkner's method for the energy levels of the shallow donor in silicon and germanium at zero field is made in order to investigate the effects of a magnetic field upon the excited states. The effective-mass Hamiltonian matrix elements of an electron bound to a donor center and subjected to a magnetic field B, which involves both the linear and quadratic terms of magnetic field, are expressed analytically and matrices are solved numerically. The photothermal ionization spectroscopy of phosphorus in ultrapure silicon for magnetic fields parallel to the [1,0,0] and [1,1,1] directions and up to 10 T is explained successfully.
Resumo:
We have conducted numerical studies of ballistic electron transport in a semiconductor II-structure when an external transverse electric field is applied. The device conductance as a function of electron energy and the strength of the transverse electric field is calculated on the basis of tight-binding Green's function formalism. The calculations show that a relatively weak electric field can induce very large decrease in the electron transmission across the structure. When the transverse electric field is sufficiently strong, electrons can hardly be transported through the device. Thus the performance of the device can be greatly improved for it is much easier to control electron transport through the device with an external transverse electric field.
Resumo:
A single longitudinal mode and narrow line width external cavity semiconductor laser is proposed. It is constructed with a semiconductor laser, collimator, a flame grating, and current and temperature control systems. The one facet of semiconductor laser is covered by high transmission film, and another is covered by high reflection film. The flame grating is used as light feedback element to select the mode of the semiconductor laser. The temperature of the constructed external cavity semiconductor laser is stabilized in order of 10(-3)degreesC by temperature control system. The experiments have been carried out and the results obtained-the spectral fine width of this laser is compressed to be less than 1.4MHz from its original line-width of more than 1200GHz and the output stability (including power and mode) is remarkably enhanced.
Resumo:
An external cavity semiconductor laser interferometer used to measure far distance micro-vibration in real time is proposed. In the interferometer, a single longitudinal mode and excellent coherent characteristic grating external cavity semiconductor laser is constructed and acted as a light source and a phase compensator. Its coherent length exceeds 200 meters. The angle between normal and incidence beam of the far object is allowed to change in definite range during the measurement with this interferometer, and this makes the far distance interference measurement easier and more convenient. Also, it is not required to keep the amplitudes of the first and second harmonic components equal, and then the dynamic range is increased. A feedback control system is used to compensate the phase disturbance between the two interference beams introduced by environmental vibration.
Resumo:
In this paper, an experiment on tunable resonant cavity enhanced (RCE) photodetector with external cavity is reported. It is the first time to realize a tunable RCE photodetector in China. A tuning range about 10 nm has been obtained and further extension is expected. Corresponding theoretical analysis and discussions are presented. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
A broadly tunable and high-power grating-coupled external cavity laser with a tuning range of more than 200 nm and a similar to 200-mW maximum output power was realized, by utilizing a gain device with the chirped multiple quantum-dot (QD) active layers and bent waveguide structure. The chirped QD active medium, which consists of QD layers with InGaAs strain-reducing layers different in thickness, is beneficial to the broadening of the material gain spectrum. The bent waveguide structure and facet antireflection coating are both effective for the suppression of inner-cavity lasing under large injection current.
Resumo:
We present a novel system design that can generate the optimized wavelength-tunable optical pulse streams from an uncooled gain-switched Fabry-Perot semiconductor laser using an optical amplifier as external light source. The timing jitter of gain-switched laser has been reduced from about 3 ps to 600 fs and the pulse width has been optimized by using our system. The stability of the system was also experimentally investigated. Our results show that an uncooled gain-switched FP laser system can feasibly produce the stable optical pulse trains with pulse width of 18 ps at the repetition frequency of 5 GHz during 7 h continuous working. We respectively proved the system feasibility under 1 GHz, 2.5 GHz and 5 GHz operation. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The physics-based parameter: load/unload response ratio (LURR) was proposed to measure the proximity of a strong earthquake, which achieved good results in earthquake prediction. As LURR can be used to describe the damage degree of the focal media qualitatively, there must be a relationship between LURR and damage variable (D) which describes damaged materials quantitatively in damage mechanics. Hence, based on damage mechanics and LURR theory, taking Weibull distribution as the probability distribution function, the relationship between LURR and D is set up and analyzed. This relationship directs LURR applied in damage analysis of materials quantitatively from being qualitative earlier, which not only provides the LURR method with a more solid basis in physics, but may also give a new approach to the damage evaluation of big scale structures and prediction of engineering catastrophic failure. Copyright (c) 2009 John Wiley & Sons, Ltd.
Resumo:
The physics-based parameter: load/unload response ratio (LURR) was proposed to measure the proximity of a strong earthquake, which achieved good results in earthquake prediction. As LURR can be used to describe the damage degree of the focal media qualitatively, there must be a relationship between LURR and damage variable (D) which describes damaged materials quantitatively in damage mechanics. Hence, based on damage mechanics and LURR theory, taking Weibull distribution as the probability distribution function, the relationship between LURR and D is set up and analyzed. This relationship directs LURR applied in damage analysis of materials quantitatively from being qualitative earlier, which not only provides the LURR method with a more solid basis in physics, but may also give a new approach to the damage evaluation of big scale structures and prediction of engineering catastrophic failure. Copyright (c) 2009 John Wiley & Sons, Ltd.
Resumo:
单宁是一种典型的有毒难降解污染物,在制革、造纸、制药、印染等行业废水中广泛存在,对水环境造成污染并且影响废水生物处理效果。本研究针对含单宁废水生物处理效率低、较高浓度时微生物受抑制且污泥容易膨胀等问题,采用超声和磁粉来强化含单宁废水生物处理,研究超声和磁粉对微生物活性、污染物去除及污泥沉降性能的影响,并对其作用机理进行了分析和探讨。 研究结果表明,活性污泥系统中单宁酸容积负荷可以达到1.8kgCOD/(m3·d),单宁酸和COD去除率分别达到85.2%和79.6%,但如果负荷进一步增大则微生物活性迅速降低。系统在pH 5~8、温度20~35℃、DO>1 mg/L的条件下具有较好的单宁酸降解效果和处理稳定性。单宁降解动力学参数为:μmax =0.208h-1;Ks=226mg/L;Ki=522mg/L;kd=0.0092h-1;Y =0.594。 磁粉对系统处理效果和污泥沉降性能有一定的促进作用,且效果要优于外磁场。适宜的磁粉粒径和投加量分别为0.05~0.15mm和1.0g/L,COD去除率比对照系统提高6.4%,SVI降低28.6%,污泥絮体结构紧密。磁粉强化主要是通过其对污泥菌胶团的凝聚、吸附作用以及对微生物活性的强化作用实现。 在适当强度(0.4W/cm2)和辐照时间(20min)的超声作用下污泥絮体和细胞膜通透性增大,酶分泌也增多,系统的COD去除率比对照提高了8.8%,单宁酶酶活提高了11%。但超声也使污泥絮体结构松散,沉降性能下降,SVI比对照系统升高9.3%。 由于污泥流失加剧导致污泥浓度相对较低,声磁联合强化系统相对于磁粉强化系统其处理效果并没有提高。但相对于单纯活性污泥系统,声磁联合作用下系统处理效果、污泥沉降性能以及系统运行稳定性都得到明显改善。本研究为难降解废水的生物处理提供了一个新的思路。 Tannins are typical refractory and toxic pollutants that commonly exist in wastewater from dye, medicine, paper and leather industries and cause many problems associated with environmental pollution and biological treatment of wastewater. Biological treatment efficiency of tannin-containing wastewater is usually low owing to its biological toxicity and low biodegradability, microbes are usually inhibited under high tannin concentration and sludge bulking frequently occurs. In this study, ultrasound and magnetic powder were used to improve the biological treatment performance of simulated tannic acid-containing wastewater. The effects of ultrasonic irradiation and magnetic powder on microbial activity, tannic acid degradation rate and sludge sedimentation were investigated. The augmentation mechanisms were analyzed and discussed. The experimental results showed that the microbes were prominently inhibited under high tannic acid concentration, but moderate degradation efficiency can be maintained under a tannic acid load of up to 1.8kgCOD/(m3·d), with the tannic acid degradation and COD removal percentage of 85.2% and 79.6% respectively. The highest degradation rates and treatment stability were achieved at pH range of 5~8, temperature range of 20~35℃ and DO concentration of above 1mg/L. The kinetic parameters were estimated, including: μmax =0.208h-1;Ks=226mg/L;Ki=522mg/L;kd=0.0092h-1;Y =0.594. The microbial activity, tannic acid degradation rate and sludge sedimentation were improved by adding Fe3O4 magnetic powder, and the augmentation performance was better than external magnetic field. The appropriate particle size and dosage of magnetic powder were found to be 0.05~0.15mm and 1.0g/L, respectively, under which the COD removal percentage was improved by 6.4% and SVI value decreased by 28.6%, and compact floc structure was observed. This was mainly caused by the flocculation and adsorption effects of magnetic powder against sludge floc and the stimulation of microbial activity under appropriate magnetic field. Under appropriate ultrasonic irradiation (ultrasonic intensity 0.4W/cm2, ultrasonic irradiation time 20min), the permeability of floc and cell membrane are improved, transfer of substrate and oxygen were reinforced; meanwhile, more enzyme were produced by microbes under the slight damage caused by ultrasound. However, the floc structure became loose under ultrasonic irradiation, leading to relatively poor sedimentation, with the SVI value 9.3% higher than the control system. Although the magnetic powder-ultrasonic irradiation combined augmentation system showed no improvement in treatment performance compared with sole magnetic augmentation system owing to its relatively low sludge concentration, it guaranteed the stable operation of system, meanwhile the tannic acid degradation and sludge sedimentation were significantly improved compared with sole activated sludge system. This study gives a new idea for biological treatment of refractory wastewater.
Resumo:
Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator af...
Resumo:
To study the injection of additional electrons from an external electron gun into the plasma of a Penning ionization gauge (PIG) ion source, a test bench for the external electron-beam enhancement of the PIG (E-PIG) ion source was set up. A source magnet assembly was built to satisfy the request for magnetic field configuration of the E-PIG ion source. Numerical calculations have been done to optimize the magnetic field configuration so as to fit the primary electrons to be fed into the PIG discharge chamber along the spreading magnetic field lines. Many possible methods for improving the performance and stability of the PIG ion source have been used in the E-PIG ion source, including the use of multicrystal LaB6 cathode and optimized axial magnetic field. This article presents a detailed design of the E-PIG ion source. Substantial enhancement of ion charge state is expected to be observed which demonstrates that the E-PIG is a viable alternative to other much more costly and difficult to operate devices for the production of intense ion beams of higher charge state.