Studies of timing for a TOF counter at external target facility


Autoria(s): 余玉洪; 徐华根; 徐瑚珊等
Data(s)

01/09/2009

Resumo

Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator af...

Identificador

http://ir.impcas.ac.cn/handle/113462/164

http://www.irgrid.ac.cn/handle/1471x/127500

Idioma(s)

英语

Fonte

余玉洪;徐华根;徐瑚珊等.Studies of timing for a TOF counter at external target facility,Chinese Physics C,2009,33(9):781

Palavras-Chave #原子核物理学 #external target facility
Tipo

期刊论文