110 resultados para DETECTION SYSTEM


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on the semiconductor laser whose spectral line with width is compressed to be less than 1.2Mhz, a system was designed to measure and improve the amplitude and frequency of the real-time microvibration with sinusoidal modulation. real-time microvibration measurement was executed without alignment problem in the interferometry; and low-frequency disturbance of environment could be eliminated. Suggestions were also given to consummate the system. The system also has resistance against the low frequency disturbance of the environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the ground target detection, classification and sensor fusion problems in distributed fiber seismic sensor network. Compared with conventional piezoelectric seismic sensor used in UGS, fiber optic sensor has advantages of high sensitivity and resistance to electromagnetic disturbance. We have developed a fiber seismic sensor network for target detection and classification. However, ground target recognition based on seismic sensor is a very challenging problem because of the non-stationary characteristic of seismic signal and complicated real life application environment. To solve these difficulties, we study robust feature extraction and classification algorithms adapted to fiber sensor network. An united multi-feature (UMF) method is used. An adaptive threshold detection algorithm is proposed to minimize the false alarm rate. Three kinds of targets comprise personnel, wheeled vehicle and tracked vehicle are concerned in the system. The classification simulation result shows that the SVM classifier outperforms the GMM and BPNN. The sensor fusion method based on D-S evidence theory is discussed to fully utilize information of fiber sensor array and improve overall performance of the system. A field experiment is organized to test the performance of fiber sensor network and gather real signal of targets for classification testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The basic principle and critical characteristics of unattended ground sensors (UGS) based on fiber optic disk accelerometers are introduced. Mechanical principles of fiber optic disk accelerometers (FODA) and calculation methods are presented. An FODA with a high sensitivity of 120rad/g and a resonance frequency of 300Hz is designed and used for detection in military affair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Homoepitaxial growth of 4H-SiC p(+)/pi/n(-) multi-epilayer on n(+) substrate and in-situ doping of p(+) and pi-epilayer have been achieved in the LPCVD system with SiH4+C2H4+H-2. The surface morphologies, homogeneities and doping concentrations of the n(-)-single-epilayers and the p(+)/pi/n(-) multi-epilayers were investigated by Nomarski, AFM, Raman and SIMS, respectively. AFM and Raman investigation showed that both single- and,multi-epilayers have good surface morphologies and homogeneities, and the SIMS analyses indicated the boron concentration in p+ layer was at least 100 times higher than that in pi layer. The UV photodetectors fabricated on 4H-SiC p(+)/pi/n(-) multi-epilayers showed low dark current and high detectivity in the UV range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel architecture of vision chip for fast traffic lane detection (FTLD). The architecture consists of a 32*32 SIMD processing element (PE) array processor and a dual-core RISC processor. The PE array processor performs low-level pixel-parallel image processing at high speed and outputs image features for high-level image processing without I/O bottleneck. The dual-core processor carries out high-level image processing. A parallel fast lane detection algorithm for this architecture is developed. The FPGA system with a CMOS image sensor is used to implement the architecture. Experiment results show that the system can perform the fast traffic lane detection at 50fps rate. It is much faster than previous works and has good robustness that can operate in various intensity of light. The novel architecture of vision chip is able to meet the demand of real-time lane departure warning system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reliable messaging is a key component necessary for mobile agent systems. Current researches focus on reliable one-to-one message delivery to mobile agents. But how to implement a group communication system for mobile agents remains an open issue, which is a powerful block that facilitates the development of fault-tolerant mobile agent systems. In this paper, we propose a group communication system for mobile agents (GCS-MA), which includes totally ordered multicast and membership management functions. We divide a group of mobile agents into several agent clusters,and each agent cluster consists of all mobile agents residing in the same sub-network and is managed by a special module, named coordinator. Then, all coordinators form a ring-based overlay for interchanging messages between clusters. We present a token-based algorithm, an intra-cluster messaging algorithm and an inter-cluster migration algorithm to achieve atomicity and total ordering properties of multicast messages, by building a membership protocol on top of the clustering and failure detection mechanisms. Performance issues of the proposed system have been analysed through simulations. We also describe the application of the proposed system in the context of the service cooperation middleware (SCM) project.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A glutamate biosensor based on the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH), which was generated by the enzymatic reaction, was developed via employing a single-walled carbon nanotubes/thionine (Th-SWNTs) nanocomposite as a mediator and an enzyme immobilization matrix. The biosensor, which was fabricated by immobilizing glutamate dehydrogenase (GIDH) on the surface of Th-SWNTs, exhibited a rapid response (ca. 5 s), a low detection limit (0.1 mu M), a wide and useful linear range (0.5-400 mu M), high sensitivity (137.3 +/- 15.7) mu A mM(-1) cm(-2), higher biological affinity, as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low operating potential (190 mV vs. NHE). The biosensor can be used to quantify the concentration of glutamate in the physiological level. The Th-SWNTs system represents a simple and effective approach to the integration of dehydrogenase and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Real-time detection of single electron tunneling through a T-shaped double quantum dot is simulated, based on a Monte Carlo scheme. The double dot is embedded in a dissipative environment and the presence of electrons on the double dot is detected with a nearby quantum point contact. We demonstrate directly the bunching behavior in electron transport, which leads eventually to a super-Poissonian noise. Particularly, in the context of full counting statistics, we investigate the essential difference between the dephasing mechanisms induced by the quantum point contact detection and the coupling to the external phonon bath. A number of intriguing noise features associated with various transport mechanisms are revealed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A distributed temperature sensor based on Rayleigh scattering Brillouin optical time domain analysis (Rayleigh-BOTDA) is proposed in this paper. The sensor uses Rayleigh backscattering effect of microwave modulated pulse base sidebands as probe wave and a high sensitive photon counting detector for Brillouin signal intensity detection. Compared with a conventional BOTDA system, the Rayleigh-BOTDA effectively suppresses polarization-induced signal fluctuation resulting in improved signal intensity. The experimental scheme presented is simplified by using a single laser with one-end access. The temperature accuracy of the new sensing system was demonstrated as 1 degrees C on spatial resolution of 3 m.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

介绍了在CSR同步加速器高频控制系统改进项目中,高频前端控制器的改进设计。根据系统改进的具体要求,采用DSP+FPGA双电路板的体系结构,对高频前端控制器各个部分做了详细的设计,并给出了具体的资源消耗结果和设计图。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

介绍了一种基于CPLD设计的电源控制模块,并且利用Atmegal128单片机和RTL8019S实现逻辑功能和远程控制功能。该电源系统主要用于重离子加速器注入器(SFC)中,具有很好的灵活性、可远程控制、性能稳定等特点。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

介绍了一种基于一线总线数字温度传感器的HIFRL-CSR循环冷却水温度远程测量系统,阐述了以DT400模块为核心的温度测量的硬件模块和软件设计。该系统具有测温精度高、易扩展性、低成本、低功耗、可靠性高、抗干扰能力强等特点,根据不同需要可应用于多种温度测量系统中。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

介绍了国家重大科学工程项目——兰州重离子加速器冷却存储环(HIRFL-CSR)的实验环(CSRe)团簇内靶温度闭环控制器的设计。该控制器给气体喷嘴处测温电阻提供长时间稳定度为0.1%的1mA恒定电流,通过12位ADC得到喷嘴温度,并通过混合信号处理器MSP430F149来实现制冷/加热闭环操作。在多种不同实验气体的情况下,该控制器的温度控制精度小于0.5K。目前,该控制器在现场工作良好。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-Cov). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.