88 resultados para Fetal calf serum


Relevância:

20.00% 20.00%

Publicador:

Resumo:

H-1 NMR spectroscopy has been used to assess long-term toxicological effects of a rare earth. Male Wistar rats were administrated orally with La(NO3)(3) at doses of 0.1, 0.2, 2.0, 10, and 20 mg/kg body wt, resp., for 3-6 months. Urine was collected at 1, 2, and 3 months and serum samples were taken after 6 months. Numerous low-M-r metabolites in rats serum and rats urine, including creatinine, citrate, glucose, ketone bodies, trimethylamine N-oxide (TMAO), and various amino acids, were identified on 400- and 500-MHz H-1 NMR spectra. La3+-induced renal and liver damage is characterized by an increase in the amounts of the excreted ketone bodies, amino acids, lactate, ethanol, succinate, TMAO, dimethylamine, and taurine and a decrease in citrate, glucose, urea, and allantoin. Information on the molecular basis of the long-term toxicity of La(NO3)(3) was derived from the abnormal patterns of metabolite excretions. An assay of some biochemical indexes and analysis of some enzymes in plasma supported NMR results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance biosensor has been used to determine antibody activity in serum. As a model system, the interaction of mouse IgG and sheep anti-mouse IgG polyclonal antibody was investigated in real time. The factors, including pH value, ionic strength, protein concentration, influencing electrostatic adsorption of mouse IgG protein onto carboxylated dextran-coated sensor chip surface, were studied. The procedures of mouse IgG protein immobilization and immune reaction were monitored in real time. The regeneration effect using the different elution reagents was also investigated. The same mouse IgG immobilized surface can be used for 100 cycles of binding and elution with only 0.38% loss per regeneration in reactivity. The results show that the surface plasmon resonance biosensor is a rapid, simple, sensitive, accurate and reliable detection technique for real-time immunoassay of antibody activity. The assay allows antibodies to be detected and studied in their native form without any purification. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxidation and adsorption of the temperature-denatured DNA at GC electrode are studied by differential pulse voltammetry and in situ FTIR spectroelectrochemistry. The temperature-denatured DNA is adsorbed and formed a DNA multilayer at electrode surface. The temperature-denatured DNA showing partly reversible process was first observed based on the reduction peaks appearing at negative scans and the reversible spectral change. The oxidation product of the temperature-denatured DNA can not diffuse away from the electrode surface easily due to the impediment of the DNA multilayer, so it can be partly reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DNA interaction with cationic lipids promises to be a versatile and effective synthetic transfection agent. This paper presents the study on binding of a simple artifical cationic lipid, cetyltrimethylammonium bromide (CTAB), to calf thymus DNA (CT DNA) prior to the condensation process, taking methyl green (MG) as a probe. The results show that the CTAB binds to DNA through electrostatic interaction forming a hydrophobic complex, thus changing the micro-environment of duplex of DNA, so the binding state of MG and DNA is changed, and a complex CTAB-CT DNA-MG is formed. This fact suggests a new way to mediate the conformation of molecular assemblies of DNA and lipids. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biosensor based on surface plasmon resonance(SPR) technology is a very useful tool to study the interaction between biomolecles. The main advantages of this technique is to "visualize" macromolecular interactions directly in real time, and in a label-free mode rather than indirect methods like enzyme-linked immunosorbent assays (ELISAs). We immobilize human serum albumin (HSA) to the carboxymethyldextran-modified sensor chip surface covalently to detect the activity of anti-HSA in serum, and regenerate the surface with .1 mol/L phosphoric acid. The results show that SPR biosensor can detect the activity of anti-HSA in real-time quickly and the sensor chip can be used over 100 cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the water relaxation enhancement behavior of Gd-diethylenetriamine pentaacetic acid(DTPA) in water and in aqueous solution of bovine serum albumine(BSA) has been studied. The T-1 relaxivity of Gd-DTPA in BSA solution is higher than that in aqueous solution. The results indicate that Gd-DTPA can integrate non-covalently with BSA mainly in forms of (Gd-DTPA) . BSA, (Gd-DTPA)(2) . BSA, for which the apparent equilibrium constant is 0.026 mmol(-1).L,0.0018 mmol(-2).L-2 respectively. This method would be used to study the interactivities between protein and contrast agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The irreversible conformational transition of bovine serum albumin (BSA) from alpha-helix to beta-sheet, induced by electric field near the electrode surface, was monitored by circular dichroism (CD) with a long optical path thin layer cell (LOPTLC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conformational transition of disulfides in bovine serum albumin (BSA) induced by electrochemical redox reaction of disulfides were monitored by in-situ circular dichroism (CD) spectroelectrochemistry, with a long optical path thin layer cell and analyzed by a singular value decomposition least square (SVDLS) method. Electrochemical reduction of disulfides drives the left-handed conformation of disulfides changed into the right-handed. At open circuit, eight of the 17 disulfides were of left-handed conformation. Four of the 17 disulfides took part in the electrochemical reduction with an EC mechanism. Only one-fourth of the reduced disulfides returned to left-handed conformation in the re-oxidation process. Some parameters of the electrochemical reduction process, i.e. the number of electrons transferred and electron transfer coefficient, n=8, alphan=0.15, apparent formal potential, E-1(0') = -0.65(+/-0.01) V, standard heterogeneous electron transfer rate constant, k(1)(0) = (2.84 +/- 0.14)x 10(-5) cm s(-1) and chemical reaction equilibrium constant, K-c=(5.13 +/- 0.12) x 10(-2), were also obtained by double logarithmic analysis based on the near-UV absorption spectra with applied potentials. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In-situ Fourier transform infra-red (FTIR) spectra of native and thermally denatured calf thymus DNA (CT DNA) adsorbed and/or oxidized at a glassy carbon (GC) electrode surface are reported. The adsorption of native DNA occurs throughout the potential range (-0.2 similar to 1.3 V) studied, and the adsorbing state of DNA at electrode surface is changed from through the C=O band of bases and pyrimidine rings to through the C=O of cytosine and imidazole rings while the potential shifts negatively from 1.3 V to -0.2 V. An in-situ FTIR spectrum of native CT DNA adsorbed at GC electrode surface is similar to that of the dissolved DNA, indicating that the structure of CT DNA is not distorted while it is adsorbed at the GC electrode surface. In the potential range of -0.2 similar to 1.30 V, the temperature-denatured CT DNA is adsorbed at the electrode surface first, then undergoes electrochemical oxidation reaction and following that, diffuses away from the electrode surface. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The water relaxation enhancement behavior of GdDTPA in human serum albumin (HSA) solution has been studied. The results indicate that GdDTPA can integrate noncovalently with HSA, mainly in forms of (GdDTPA)HSA and (GdDTPA),HSA, for which the apparent equilibrium constants are 0.05 mM(-1) and 0.02 mM(-2), respectively. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable gadolinium complexes, such as Gd(DTPA) and Gd(DOTA), are usually used as the contrast agents for magnetic resonance imaging(MRI). Reported here are the enhanced relaxation properties of a novel gadolinium complex, diethylene-triaminopentaacetate Lis (isoniazid) [Gd(DTPA-BIN)], in aqueous and in human serum albumin(HSA) solution, which indicates that (1) two Gd(DTPA-BIN) can integrate non-covalently with one HSA with an equilibrium constant of 0. 02 mmol(-2) . L-2 ; (2) the relaxivities are 3. 28 and 4. 92 mmol(-1) . L . s(-1) for the free Gd(DTPA-BIN) and the [Gd(DTPA-BIN)](2), HSA conjugator, respectively; (3) the rotational correlation time of protein conjugator is notably higher than that of the free complex, The above results may imply that Gd(DTPA-BIN) has a higher tissue selectivity than that of its parent Gd(DTPA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1.0 moll(-1) HCl with a pulse current density of 20 mA cm(-2), and the pulse wave parameters of t(a)/t(c) = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t(r)) to the working time (t(w)) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 moll(-1) KCl was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper. the interaction of tripositive terbium ions (Tb3+) with bovine serum albumin (BSA) has been investigated in the presence of some alkaline earth metals and citric acid (Cit) by using fluorescence spectroscopy. The results show that Tb-31. BSA and Cit can form ternary complex BSA . Tb-2. Cit(4) in mu =0.1 mol/l NaCl. pH6.3 hexamethylenetetramine buffer. Other tare earths are able to compete for the same binding site in BSA with Tb3+-. The sequence of con,petition is Eu3+>Pr3+>Yb3+>Gd3+>La3+>Ca2+ and Mg2+ cannot replace Tb bound to BSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electro-oxidation of bilirubin (BR) in aqueous solution was investigated by cyclic voltammetry and in-situ thin-layer spectroelectrochemical techniques, It was found that both oxidation processes of BR are two electron transfer reactions. A mechanism