110 resultados para Feeding techniques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were conducted to identify the rules of the individual sense organs in the feeding behaviour of Chinese perch Siniperca chuatsi by determining the consumption of natural food after selective removal or blocking of eyes, lateral lines and olfactory organs, and also by observing the behavioural response to visual, mechanical and chemical stimulation by artificial prey. Chinese perch were able to feed properly on live prey fish when either eyes or lateral lines were intact or functional, but could scarcely feed without these two senses. Chinese perch recognized its prey by vision through the perception of motion and shape, and showed a greater dependence on vision in predation when both visual and mechanical cues were available. Chemical stimulation by natural food could not elicit any feeding response in Chinese perch, and gustation was only important to the fish for the last stage of food discrimination in the oropharyngeal cavity. The sensory basis of Chinese perch in feeding is well adapted to its nocturnal stalking hunting strategy. and also explains its peculiar food habit of accepting live prey fish only and refusing dead prey fish or artificial diets. (C) 1998 The Fisheries Society of the British Isles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Juvenile (mean +/- SE, 8.6 +/- 0.1 g) white sturgeon Acipenser transmontanus were fed for 8 weeks under one of six feeding regimens: continuously 24 h/d (C24); continuously 12.8 h/d during the day (C12/D), continuously 12.8 h/d at night (C12/N), 6 meals/d (M6), 4 meals/d (M4), and 2 meals/d (M2). Specific growth rate, feed efficiency, and body lipid content were significantly (P < 0.05) affected by the feeding regimen. These variables were highest in the C24 group and lowest in the M2 group; fish in the M6 group showed the second best performance. Specific growth rate and feed efficiency in terms of wet weight in the M6 groups were not significantly different from those in the C24 groups, but specific growth rate in terms of energy and energy retention efficiency were significantly lower. Feeding regimen had no effect on condition factor, hepatosomatic index, coefficient of variation in final body weight, and protein and ash contents. There was no significant difference in these indexes between 12.8-h/d continuous feeding by day or by night. It was concluded that continuous feeding for 24 h/d was the optimum feeding regimen for juvenile white sturgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two 8-week growth trials were conducted to determine the effect of continuous (CF) versus 2 meals day(-1) (MF) feeding and 30% starch versus 30% glucose diets on the carbohydrate utilization of 9.0-g white sturgeon and 0.56-g hybrid tilapia. The two trials were conducted under similar conditions except that sturgeon were kept at 18.5 degrees C in a flow-through system and tilapia were kept at 26 degrees C in a recirculating system. Significantly (P less than or equal to 0.05) higher specific growth rate (SGR), feed efficiency (FE), protein efficiency ratio (PER), body lipid content and liver glucose-6-phosphate dehydrogenase (G6PDH) and 6-phosphogluconate dehydrogenase (6PGDH) activities were observed in the CF than MF sturgeon. Only SGR, FE and PER were higher in sturgeon fed the starch than the glucose diets. Only higher liver G6PDH and malic enzyme (ME) activities were observed in the CF than MF tilapia but higher SGR, FE, PER and liver G6PDH, 6PGDH and ME activities were observed in tilapia fed the starch diet than those fed the glucose diet. This suggested that carbohydrate utilization by sturgeon was more affected by feeding strategy whereas tilapia was more affected by carbohydrate source. Furthermore, white sturgeon can utilize carbohydrates better than hybrid tilapia regardless of feeding strategy and carbohydrate source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feeding intensities (number of bites per minute) were recorded each hour over a 24-h diel cycle for young grass carp fed three diets. The grass carp did not show distinct meals. Grass carp receiving plant diets (duckweed or elodea) fed almost continuously throughout the 24 h, while fish fed the animal diet (tubificids) ceased feeding or had very low feeding intensities for about a quarter of the diel cycle. The average feeding intensity in fish fed duckweed was three times higher than that in fish fed elodea and tubificids. Average dry matter intake per bite was much higher in fish fed the animal diet than in those fed the plant diets. In most individuals, there was no significant difference in feeding intensity between daytime and nighttime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this letter, the power spectrum of a cooled distributed feedback laser module is measured using the self-heterodyne technique. Periodical oscillation peaks have been observed in the measurement. Further investigation shows that the additional modulation signal is coupled from the thermal electric cooler (TEC) controller to the laser driver, and then applied to the laser diode. The additional modulation can be eliminated by properly isolating the laser driving source from the TEC controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two simple methods for estimating the potential modulation bandwidth of TO packaging technique are presented. The first method is based upon the comparison of the measured frequency responses of the laser diodes and the TO laser modules, and the second is from the equivalent circuit for the test fixture, the TO header, the submount and the bonding wire. It is shown that the TO packaging techniques used in the experiments can potentially achieve a frequency bandwidth of over 10.5 GHz, and the two proposed methods give similar results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effects of techniques of implanting nitrogen into buried oxide on the characteristics of the partially depleted silicon-on-insulator (SOI) p-channel metal-oxide-semiconductor field-effect transistors (PMOSFETs) have been studied with three different nitrogen implantation doses, 8 x 10(15), 2 x 10(16), and 1 x 10(17) cm(-2). The experimental results show that this technology can affect the threshold voltage, channel hole mobility and output characteristics of the partially depleted SOI PMOSFETs fabricated with the given material and process. For each type of the partially depleted SOI PMOSFET with nitrided buried oxide, the absolute value of the average threshold voltage increases due to the nitrogen implantation. At the same time, the average channel hole mobility decreases because of the nitrogen implantation. In particular, with the high nitrogen implantation doses, the output characteristic curves of the tested transistors present a distinct kink effect, which normally exists in the characteristic output curves of only partially depleted SOI NMOSFETs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scattering parameters of photodiode chip, TO header and TO packaged module are measured, and the effects of TO packaging network on the high-frequency response of photodiode are investigated. Based on the analysis, the potential bandwidth of TO packaging techniques is estimated from the scattering parameters of the TO packaging network. Another method for estimating the potential bandwidth from the equivalent circuit for the TO packaged photodiode model is also presented. The results obtained using both methods show that the TO packaging techniques used in the experiments can potentially achieve a frequency bandwidth of 22 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A SiGe/Si multiple-quantum-well resonant-cavity-enhanced (RCE) photodetector for 1.3 mum operation was fabricated using bonding reflector process. A full width at half maximum (FWHM) of 6 nm and a quantum efficiency of 4.2% at 1314 nm were obtained. Compared to our previously reported SiGe RCE photodetectors fabricated on separation-by-implanted-oxygen wafer, the mirrors in the device can be more easily fabricated and the device can be further optimized. The FWHM is expected to be less than 1 nm and the detector is fit for density wavelength division multiplexing applications. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conduction-band offset Delta E-C has been determined for a molecular beam epitaxy grown GaAs/In0.2Ga0.8As single quantum-well structure, by measuring the capacitance-voltage (C - V) profiling, taking into account a correction for the interface charge density, and the capacitance transient resulting from thermal emission of carriers from the quantum well, respectively. We found that Delta E-C = 0.227 eV, corresponding to about 89% Delta E-g, from the C - V profiling; and Delta E-C = 0.229eV, corresponding to about 89.9% Delta E-g, from the deep-level transient spectroscopy (DLTS) technique. The results suggest that the conduction-band discontinuity Delta E-C obtained from the C-V profiling is in good agreement with that obtained from the DLTS technique. (C) 1998 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The composition and stain distributions in the InGaN epitaxial films are jointly measured by employing various x-ray diffraction (XRD) techniques, including out-of-plane XRD at special planes, in-plane grazing incidence XRD, and reciprocal space mapping (RSM). It is confirmed that the measurement of (204) reflection allows a rapid access to estimate the composition without considering the influence of biaxial strain. The two-dimensional RSM checks composition and degree of strain relaxation jointly, revealing an inhomogeneous strain distribution profile along the growth direction. As the film thickness increases from 100 nm to 450 nm, the strain status of InGaN films gradually transfers from almost fully strained to fully relaxed state and then more in atoms incorporate into the film, while the near-interface region of InGaN films remains pseudomorphic to GaN.