Development of current-based microscopic defect analysis method using optical filling techniques for the defect study on heavily irradiated high-resistivity Si sensors/detectors


Autoria(s): Li, Z (Li, Z.); Li, CJ (Li, C. J.)
Data(s)

2006

Resumo

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

Current-based microscopic defect analysis method such as current deep level transient spectroscopy (I-DLTS) and thermally stimulated current have been developed over the years at Brookhaven National Laboratory (BNL) for the defect characterizations on heavily irradiated (Phi(n) >= 10(13) n/cm(2)) high-resistivity (>= 2 k Omega cm) Si sensors/detectors. The conventional DLTS method using a capacitance transient is not valid on heavily irradiated high-resistivity Si sensors/detectors. A new optical filling method, using lasers with various wavelengths, has been applied, which is more efficient and suitable than the traditional voltage-pulse filling. Optimum defect-filling schemes and conditions have been suggested for heavily irradiated high-resistivity Si sensors/detectors. (c) 2006 Published by Elsevier Ltd.

zhangdi于2010-03-29批量导入

zhangdi于2010-03-29批量导入

Brookhaven Natl Lab, Upton, NY 11973 USA; Chinese Acad Sci, Inst Semicond, Beijing 100083, Peoples R China

Identificador

http://ir.semi.ac.cn/handle/172111/10000

http://www.irgrid.ac.cn/handle/1471x/66001

Idioma(s)

英语

Publicador

ELSEVIER SCI LTD

THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND

Fonte

Li, Z (Li, Z.); Li, CJ (Li, C. J.) .Development of current-based microscopic defect analysis method using optical filling techniques for the defect study on heavily irradiated high-resistivity Si sensors/detectors .见:ELSEVIER SCI LTD .MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING,THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND ,FEB-JUN 2006,9 (1-3): 283-287

Palavras-Chave #半导体器件 #DLTS
Tipo

会议论文