54 resultados para Vibration tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An association of the dopamine receptor D4 (DRD4) gene located on chromosome 11p15.5 and attention deficit/hyperactivity disorder (ADHD) has been demonstrated and replicated by multiple investigators. A specific allele [the 7-repeat of a 48-bp variable number of tandem repeats (VNTR) in exon 3] has been proposed as an etiological factor in attentional deficits manifested in some children diagnosed with this disorder. In the current study, we evaluated ADHD subgroups defined by the presence or absence of the 7-repeat allele of the DRD4 gene, using neuropsychological tests with reaction time measures designed to probe attentional networks with neuroanatomical foci in D4-rich brain regions. Despite the same severity of symptoms on parent and teacher ratings for the ADHD subgroups, the average reaction times of the 7-present subgroup showed normal speed and variability of response whereas the average reaction times of the 7-absent subgroup showed the expected abnormalities (slow and variable responses). This was opposite the primary prediction of the study. The 7-present subgroup seemed to be free of some of the neuropsychological abnormalities thought to characterize ADHD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The polymorphism of a gene or a locus is studied with increasing frequency by multiple laboratories or the same group at different times. Such practice results in polymorphism being revealed by different samples at different regions of the locus. Tests of neutrality have been widely conducted for polymorphism data but commonly used statistical tests cannot be applied directly to such data. This article provides a procedure to conduct a neutrality test and details are given for two commonly used tests. Applying the two new tests to the chemokine-receptor gene (CCR5) in humans, we found that the hypothesis that all mutations are selectively neutral cannot explain the observed pattern of DNA polymorphism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of lattice vibration on the system in which the electron is weakly coupled with bulk longitudinal optical phonons and strongly coupled with interface optical phonons in an infinite quantum well were studied by using Tokuda' linear-combination operator and a modified LLP variational method. The expressions for the effective mass of the polaron in a quantum well QW as functions of the well's width and temperature were derived. In particular, the law of the change of the vibration frequency of the polaron changing with well' s width and temperature are obtained. Numerical results of the effective mass and the vibration frequency of the polaron for KI/AgCl/Kl QW show that the vibration frequency and the effective mass of the polaron decrease with increasing well's width and temperature, but the contribution of the interaction between the electron and the different branches of phonons to the effective mass and the vibration frequency and the change of their variation with the well's width and temperature are greatly different.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the semiconductor laser whose spectral line with width is compressed to be less than 1.2Mhz, a system was designed to measure and improve the amplitude and frequency of the real-time microvibration with sinusoidal modulation. real-time microvibration measurement was executed without alignment problem in the interferometry; and low-frequency disturbance of environment could be eliminated. Suggestions were also given to consummate the system. The system also has resistance against the low frequency disturbance of the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a high-performance multiplexed vibration sensor system using fiber lasers. A serial vibration sensor array consists of four short cavity fiber lasers. The system employs a single, polarization-insensitive, unbalanced Michelson interferometer to translate individual laser wavelength shifts induced by vibration signals into interferometer phase shifts. A dense wavelength division demultiplexor (DWDM) with high channel isolation is inserted to demultiplex each laser signal as a wavelength filter. Finally, a digital phase demodulator based on the phase generated carrier technique is used to achieve high-resolution interrogation. Experimental results show that no observable crosstalk is measured on the output channels, and the minimal detectable acceleration of this system is similar to 200ng/root Hz at 250Hz, which is fundamentally limited by the frequency noise of the lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An external cavity semiconductor laser interferometer used to measure far distance micro-vibration in real time is proposed. In the interferometer, a single longitudinal mode and excellent coherent characteristic grating external cavity semiconductor laser is constructed and acted as a light source and a phase compensator. Its coherent length exceeds 200 meters. The angle between normal and incidence beam of the far object is allowed to change in definite range during the measurement with this interferometer, and this makes the far distance interference measurement easier and more convenient. Also, it is not required to keep the amplitudes of the first and second harmonic components equal, and then the dynamic range is increased. A feedback control system is used to compensate the phase disturbance between the two interference beams introduced by environmental vibration.