98 resultados para hydrophilic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The porosity and the hydrophobicity of membranes are two essential requirements for membrane distillation (MD) of aqueous solutions. So far, the hydrophobic porous membranes used in MD studies have been prepared from hydrophobic materials. In this work, hydrophilic cellulose acetate and cellulose nitrate membranes were modified into hydrophobic membranes by radiation grafting polymerization and plasma polymerization, and used in MD studies successfully. The results indicated that modified membranes with good performance in MD can be obtained if the modifying conditions are controlled appropriately. Especially plasma polymerization, in which many particular kinds of monomer could be polymerized onto the surface of porous materials, has become an efficient method to prepare hydrophobic porous membrane with high performance from hydrophilic membranes. It will stimulate the development and practical application of MD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a good alternative method to improve the tribological properties of polymer films by chemisorbing a long-chain monolayer on the functional polymer surface. Thus, a novel self-assembled monolayer is successfully prepared on a silicon substrate coated with amino-group-containing polyethyleneimine (PEI) by the chemical adsorption of stearic acid (STA) molecules. The formation and structure of the STA-PEI film are characterized by means of contact-angle measurement and ellipsometric thickness measurement, and of Fourier transformation infrared spectrometric and atomic force microscopic analyses. The micro- and macro-tribological properties of the STA-PEI film are investigated on an atomic force microscope (AFM) and a unidirectional tribometer, respectively. It has been found that the STA monolayer about 2.1-nm thick is produced on the PEI coating by the chemical reaction between the amino groups in the PEI and the carboxyl group in the STA molecules to form a covalent amide bond in the presence of N,N'-dicyclohexylcarbodiimide (DCCD) as a dehydrating regent. By introducing the STA monolayer, the hydrophilic PEI polymer surface becomes hydrophobic with a water contact angle to be about 105degrees. Study of the time dependence of the film formation shows that the adsorption of PEI is fast, whereas at least 24 h is needed to generate the saturated STA monolayer. Whereas the PEI coating has relatively high adhesion, friction, and poor anti-wear ability, the STA-PEI film possesses good adhesive resistance and high load-carrying capacity and anti-wear ability, which could be attributed to the chemical structure of the STA-PEI thin film. It is assumed that the hydrogen bonds between the molecules of the STA-PEI film act to stabilize the film and can be restored after breaking during sliding. Thus, the self-assembled STA-PEI thin film might find promising application in the lubrication of micro-electromechanical systems (MEMS).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new approach is developed to the fabrication of high-quality three-dimensional macro-porous copper films. A highly-ordered macroporous copper film is successfully produced on a polystyrene sphere (PS) template that has been modified by sodium dodecyl sulfate (SDS). It is shown that this procedure can change a hydrophobic surface of PS template into a hydrophilic surface. The present study is devoted to the influence of the electrolyte solution transport on the nucleation process. It is demonstrated that the permeability of the electrolyte solution in the nanochannels of the PS template plays an important role in the chemical electrodeposition of high-quality macroporous copper film. The permeability is drastically enhanced in our experiment through the surface modi. cation of the PS templates. The method could be used to homogeneously produce a large number of nucleations on a substrate, which is a key factor for the fabrication of the high-quality macroporous copper film.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文用原子力显微术(AFM)研究了牛血清白蛋白(BSA)在亲水硅片表面的吸附,硅片表面经亲水处理后,将牛血清蛋白(BSA)吸附在表面,采用轻敲模式,可获得清晰的AFM图像,牛血清蛋白(BSA)的AFM图像表明:BSA在亲水硅片表面是单分子,水平吸附在硅片表面,且吸颗粒状;1mg/ml的BSA在吸附30min后为饱和吸附。BSA到达硅表面后,蛋白中可移动的带正电荷的基团可以趋向亲水表面,使BSA与硅表面的静电相互作用由斥力变为吸引力,BSA可以稳定地吸附在亲水硅片表面。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adsorption and competitive adsorption of collagen and bovine serum albumin (BSA) were directly visualized and quantified using atomic force microscopy (AFM) and imaging ellipsometry. Chemically modified silicon surfaces were used as hydrophilic and hydrophobic substrates. The results showed that collagen and BSA in single component solution adsorbed onto a hydrophobic surface two times more than that onto a hydrophilic surface. The competitive adsorption between collagen and BSA showed that serum albumin preferentially adsorbed onto a hydrophobic surface, while collagen on a hydrophilic surface. In the binary solution of BSA (1 mg/ml BSA) and collagen (0.1 mg/ml), nearly 100% of the protein adsorbed onto the hydrophobic surface was BSA, but on the hydrophilic surface only about 6% was BSA. Surface affinity was the main factor controlling the competitive adsorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The template-directed fabrication of highly-ordered porous film is of significant importance in implementation of the photonic band gap structure. The paper reports a simple and effective method to improve the electrodeposition of metal porous film by utilizing highly-ordered polystyrene spheres (PSs) template. By surface-modification method, the hydrophobic property of the PSs template surfaces was changed into hydrophilic one. It was demonstrated that the surface modi. cation process enhanced the permeability of the electrolyte solution in the nanometer-sized voids of the colloidal template. The homogeneously deposited copper film with the highly-ordered voids in size of less than 500 nm was successfully obtained. In addition, it was found that large defects, such as microcracks in the template, strongly influenced the macroporous films quality. An obvious preferential growth in the cracked area was observed. (C) 2008 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polydimethylsiloxane (PDMS) has been widely used as a base material for bio-MEMS/NEMS devices. It is difficult for PDMS to transfer and spread aqueous solution as a kind of highly hydrophobic material. Therefore, surface modification is necessary for PDMS to make it hydrophilic. In this paper, a method of hydrophilization of PDMS surface is proposed. Gold is sputtered to the PDMS substrate by sputter coater in different average thicknesses. Relationship between the average thickness of gold on the PDMS substrate and the contact angle of the surface was studied. It was found that even gold of average thickness less than 1 nm can result in about 25 degrees change of contact angle. AFM is also used to get topographic information of PDMS surface coated with gold. Three cases are classified with different amount of Au: (1) Heterogeneous zone; (2) Transition zone; (3) Film zone. For heterogeneous zone, a simple model about heterogeneous phase wetting is put forward to interpret this phenomenon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atomic force microscopy (AFM) was used to study the competitive adsorption between bovine serum albumin (BSA) and type I collagen on hydrophilic and hydrophobic silicon wafers. BSA showed a grain shape and the type I collagen displayed fibril-like molecules with relatively homogeneous height and width, characterized with clear twisting (helical formation). These AFM images illustrated that quite a lot of type I collagen appeared in the adsorption layer on hydrophilic surface in a competitive adsorption state, but the adsorption of BSA was more preponderant than that of type I collagen on hydrophobic silicon wafer surface. The experiments showed that the influence of BSA on type I collagen adsorption on hydrophilic surface was less than that on hydrophobic surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we measured 14 horizontal velocity profiles along the vertical direction of a rectangular microchannel with aspect ratio alpha = h/w = 0.35 (h is the height of the channel and w is the width of the channel) using microPIV at Re = 1.8 and 3.6. The experimental velocity profiles are compared with the full 3D theoretical solution, and also with a Poiseuille parabolic profile. It is shown that the experimental velocity profiles in the horizontal and vertical planes are in agreement with the theoretical profiles, except for the planes close to the wall. The discrepancies between the experimental data and 3D theoretical results in the center vertical plane are less than 3.6%. But the deviations between experimental data and Poiseuille's results approaches 5%. It indicates that 2D Poiseuille profile is no longer a perfect theoretical approximation since a = 0.35. The experiments also reveal that, very near the hydrophilic wall (z = 0.5-1 mu m), the measured velocities are significantly larger than the theoretical velocity based on the no-slip assumption. A proper discussion on some physical effects influencing the near wall velocity measurement is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluid transportation in microfluidic system could be benefit from the slip on solid-liquid interface. Slip length on many kinds of hydrophilic/hydrophobic surfaces have been measured recently. The two common-used experimental methods for boundary slip measurement include: (1) surface force measurement, such as surface force apparatus (SFA), atom force microscope (AFM), and (2) velocity measurement, like microPIV/PTV (Particle image velocimetry / Particle tracking velocimetry), total internal reflection velocimetry (TIRV). However, the measured results are rather scattered, larger measured slip lengths were reported by microPIV/PTV experiments. In this paper, we will investigate the deviations of the measured slip length on smooth hydrophilic surface. After measuring detailed velocity profiles very close to hydrophilic glass wall, we give a discussion on the effects influencing the slip measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

多孔SiO2膜层经热处理后,具有很高的激光破坏阈值,但是结构中有许多Si-OH亲水基团,导致光学透过率受环境相对湿度的影响很大。实验目的是改善膜层内部结构,使膜层结构中的亲水基团转变为疏水基团。提高膜层的疏水性,增强膜层的透过率稳定性。系统地研究了膜层透过率随时间变化的规律,在氨气和六甲基二硅氮烷(HMDS)混合气氛下热处理膜层,处理后生成Si-O-Si(CH2)3非极性疏水基团,使膜层的疏水性大大提高,因而膜层的透过率稳定性有大幅度提高。稳定性的提高延长了膜层的寿命。处理后膜层的表面粗糙度良好,均方根表

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Five models for human interleukin-7 (HIL-7), HIL-9, HIL-13, HIL-15 and HIL-17 have been generated by SYBYL software package. The primary models were optimized using molecular dynamics and molecular mechanics methods. The final models were optimized using a steepest descent algorithm and a subsequent conjugate gradient method. The complexes with these interleukins and the common gamma chain of interleukin-2 receptor (IL-2R) were constructed and subjected to energy minimization. We found residues, such as Gln127 and Tyr103, of the common gamma chain of IL-2R are very important. Other residues, e.g. Lys70, Asn128 and Glu162, are also significant. Four hydrophobic grooves and two hydrophilic sites converge at the active site triad of the gamma chain. The binding sites of these interleukins interaction with the common gamma chain exist in the first helical and/or the fourth helical domains. Therefore, we conclude that these interleukins binds to the common gamma chain of IL-2R by the first and the fourth helix domain. Especially at the binding sites of some residues (lysine, arginine, asparagine, glutamic acid and aspartic acid), with a discontinuous region of the common gamma chain of IL-2R, termed the interleukins binding sites (103-210). The study of these sites can be important for the development of new drugs. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemorrhagic disease, caused by the grass carp reovirus (GCRV), is one of the major diseases of grass carp in China. Little is known about the structure and function of the gene segments of this reovirus. The S10 genome segment of GCRV was cloned and the complete nucleotide sequence is reported here. The S10 is 909 nucleotides long and contains a large open reading frame (ORF) encoding a protein of 276 amino acids with a deduced molecular weight of approximately 29.7 kDa. Comparisons of the deduced amino acid sequence of GCRV S10 with those of other reoviruses revealed no significant homologies. However, GCRV S10 shared a putative zinc-finger sequence and a similar distribution of hydrophilic motifs with the outer capsid proteins encoded by Coho salmon aquareovirus (SCSV) S10, striped bass reovirus (SBRV) S10, and mammalian reovirus (MRV) S4. It was predicted that this segment gene encodes an outer capsid protein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From the effective absorption coefficient of bonded interface and the relationship of interface to reflectivity at cavity mode for double bonded vertical cavity laser, it can be seen that bonded interfaces should be positioned at the null of standing wave distribution, and the thickness of interface should be less than 20 nm. Using the finite elements method, the temperature contour map of laser can be calculated. Results showed that the influence of thin interface to thermal characteristics of VCSELS is slight, while thick interface will lead to temperature increase of active region. SEM images demonstrate that hydrophobic bonding is suitable for the fabrication of the device, while hydrophilic bonding interface is unfavorable to optical and thermal properties of devices with interface thickness larger than 40 nm.