Influence Of Different Amount Of Au On The Wetting Behavior Of Pdms Membrane


Autoria(s): 冯江涛; 赵亚溥
Data(s)

2008

Resumo

Polydimethylsiloxane (PDMS) has been widely used as a base material for bio-MEMS/NEMS devices. It is difficult for PDMS to transfer and spread aqueous solution as a kind of highly hydrophobic material. Therefore, surface modification is necessary for PDMS to make it hydrophilic. In this paper, a method of hydrophilization of PDMS surface is proposed. Gold is sputtered to the PDMS substrate by sputter coater in different average thicknesses. Relationship between the average thickness of gold on the PDMS substrate and the contact angle of the surface was studied. It was found that even gold of average thickness less than 1 nm can result in about 25 degrees change of contact angle. AFM is also used to get topographic information of PDMS surface coated with gold. Three cases are classified with different amount of Au: (1) Heterogeneous zone; (2) Transition zone; (3) Film zone. For heterogeneous zone, a simple model about heterogeneous phase wetting is put forward to interpret this phenomenon.

Identificador

http://dspace.imech.ac.cn/handle/311007/26160

http://www.irgrid.ac.cn/handle/1471x/2579

Idioma(s)

英语

Fonte

Biomedical Microdevices, 2008, 10(1): 65-72

Palavras-Chave #Pdms #Wetting #Hydrophilic Modification #Heterogeneous Phase #Thin Gold Layers #Polyelectrolyte Multilayers #Polydimethylsiloxane Pdms #Microfluidic Devices #Water-Repellent #Poly(Dimethylsiloxane) #Surfaces #Polyethyleneterephthalate #Discharges #Exposure
Tipo

期刊论文