399 resultados para tao
Resumo:
The construction and commissioning of HIRFL-CSR were finished in 2007. From 2000 to 2005 the subsystem and key devices of CSR were successfully fabricated, such as magnet, power supply, UHV system, e-cooler, electric-static deflector with the septum of 0.1 mm, and the fast-pulse kicker with the rise time of 150 ns. After that the CSR commissioning activities were performed in 2006 and 2007, including the accumulation of those heavy ions of C, Ar, Kr and Xe by the combination of stripping injection (STI) or multiple multi-turn injection (MMI) and e-cooling with a hollow e-beam, wide energy-range synchrotron ramping by changing the RF harmonic-number at mid-energy, the beam stacking in the experimental ring CSRe, the RIBs mass-measurement with the isochronous-mode in CSRe by using the time-of-flight method, and the ion beam slow-extraction from CSRm.
Resumo:
Four high-purity germanium 4-fold segmented Clover detectors have been applied in the experiment of neutron-rich nucleus N-21. The performance of those, four Clovers have been tested with radioactive sources and in-beam experiments and the main results including energy resolution, peak-to-total ratios, the variation of the hit pattern distribution in difficult crystals of one Clover detector with the energy of gamma ray, and absolute full energy peak detection efficiency curve, were presented.
Resumo:
In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved.
Resumo:
A method of loop-mediated isothermal amplification (LAMP) was employed to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). The amplification could be finished in 60 min under isothermal condition at 64 degrees C by employing a set of four primers targeting the cap gene of PCV2. The LAMP assay showed higher sensitivity than the conventional PCR, with a detection limit of five copies per tube of purified PCV2 genomic DNA. No cross-reactivity was observed from the samples of other related viruses including porcine circovirus type 1 (PCV1), porcine parvovirus (PPV), porcine pseudorabies virus (PRV) and porcine reproductive and respiratory syndrome virus (PRRSV). The detection rate of PCV2 LAMP for 86 clinical samples was 96.5% and appeared greater than that of the PCR method. The LAMP assay reported can provide a rapid yet simple test of PCV2 suitable for laboratory diagnosis and pen-side detection due to ease of operation and the requirement of only a regular water bath or heat block for the reaction. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
The beta-delayed neutron and gamma energy spectra taken from the decay of neutron-rich nucleus N-21 were measured by using the beta - gamma and beta - n coincidence detection method. Thirteen new neutron groups ranging from 0.28MeV to 4.98 MeV and with a total branching ratio of 88.7 +/- 4.2% were observed and presented. One gamma transition with an energy of 1222 keV emitted from the excited state of O-21, and four gamma transitions with energies of 1674, 2397, 2780, and 3175 keV emitted from the excited states of O-20 were identified in the 3 decay chain of N-21. The beta decay half-life for N-21 is determined to be 82.9 +/- 1.9 ms. The uncertainty of half-life is much smaller than the previous result.
Resumo:
Defect engineering for SiO2] precipitation is investigated using He-ion implantation as the first stage of separation by implanted oxygen (STMOX). Cavities are created in Si by implantation with helium ions. After thermal annealing at different temperatures, the sample is implanted with 120keV 8.0 x 10(16) cm(-2) O ions. The O ion energy is chosen such that the peak of the concentration distribution is centred at the cavity band. For comparison, another sample is implanted with O ions alone. Cross-sectional transmission electron microscopy (XTEM), Fourier transform infrared absorbance spectrometry (FTIR) and atomic force microscopy (AFM) measurements are used to investigate the samples. The results show that a narrow nano-cavity layer is found to be excellent nucleation sites that effectively assisted SiO2 formation and released crystal lattice strain associated with silicon oxidation.
Resumo:
利用卢瑟福沟道背散射技术结合表面的原子力显微分析,对注He的铝镁尖晶石晶体的晶格损伤及表面形变随退火温度变化的关系进行了研究.结果表明,不同注入剂量的样品中晶格损伤和表面形变表现出显著不同的退火行为.分析认为造成损伤演化的这种差异与注入的He原子在晶体中不同的聚集状态有关.
Resumo:
不同电荷态低速离子(Arq+,Pbq+)轰击Si(110)晶面,测量不同入射角情况下的次级粒子的产额. 通过比较溅射产额与入射角的关系,证实沟道效应的存在. 高电荷态离子与Si相互作用产生的沟道效应说明溅射产额主要是由动能碰撞引起的. 在小角入射条件下,高电荷态离子能够增大溅射产额. 当高电荷态离子以40°—50°入射时,存在势能越高溅射产额越大的势能效应.
Resumo:
对注入Ar+后不同晶面取向的蓝宝石晶体在不同退火条件下的光致发光谱进行了分析.分析结果表明:三种晶面取向的蓝宝石样品经Ar+注入后,其光致发光谱中均出现了新的位于506nm处的发光峰;真空和空气气氛下的退火均对样品在506nm处的发光有增强作用,不同晶面取向的样品发光增强程度不同,且发光增强至最大时的退火温度也不同,空气气氛下的退火使样品发光增强程度更为显著.由此可以看出,退火气氛、退火温度和晶面取向均对样品发光峰强度有影响.
Resumo:
介绍了自行研制的Micromegas探测器的基本结构和工作原理. 在不同工作气体(Ar和CO2)配比条件下,利用55Fe放射源对该探测器的能量分辨、计数曲线和气体增益等特性进行了较为详尽的测试. 对相关结果进行了讨论.
Resumo:
In the present work, a Cz-Silicon wafer is implanted with helium ions to produce a buried porous layer, and then thermally annealed in a dry oxygen atmosphere to make oxygen transport into the cavities. The formation of the buried oxide layer in the case of internal oxidation (ITOX) of the buried porous layer of cavities in the silicon sample is studied by positron beam annihilation (PBA). The cavities are formed by 15 keV He implantation at a fluence of 2 x 10(16) cm(-2) and followed by thermal annealing at 673 K for 30 min in vacuum. The internal oxidation is carried out at temperatures ranging from 1073 to 1473 K for 2 h in a dry oxygen atmosphere. The layered structures evolved in the silicon are detected by using the PBA and the thicknesses of their layers and nature are also investigated. It is found that rather high temperatures must be chosen to establish a sufficient flux of oxygen into the cavity layer. On the other hand high temperatures lead to coarsening the cavities and removing the cavity layer finally.
Resumo:
The status of heavy-ion cancer therapy has been reviewed. The existing and constructing heavy-ion beam facilities for cancer therapy in the world are introduced. The first clinical trials of superficially placed tumor therapy at heavy ion research facility in Lanzhou (HIRFL) are presented.
Resumo:
The beam must be extracted into the air through the vacuum window to irradiate the living cell. In the window design, the material and thickness must be chosen to compromise the beam spot size broadening and the window safety. The structure-static analysis on the window of different structures and materials is done with the finite element analysis method, and the deformation and the equivalent stress axe simulated. The safety of these candidates is investigated using the intensity theory. In addition, the small angle scattering and the transverse range of ions are simulated using SRIM code, including all the effects on the beam spot size broadening, such as the incident ion energy, the material and the thickness of the window and the air composing. At last, the appropriate vacuum windows are presented, including the structure, material and thickness.
Resumo:
The. total electron emission yields following the interaction of slow highly charged ions (SHCI) O4+ with different material surfaces (W, Au, Si and SiO2) have been measured. It is found that the electron emission yield gamma increases proportionally with the projectile velocity v ranging from 5.36 x 10(5)m/s to 10.7 x 10(5)m/s. The total emission yield is dependent on the target materials, and it turns out to follow the relationship gamma(Au) > gamma(Si)> gamma(W). The result shows that the electron emission yields are mainly determined by the electron stopping power of the target when the projectile potential energy is taken as a constant, which is in good agreement with the former studies
Resumo:
Single-crystalline Si (100) samples were implanted with 30 keV He2+ ions to doses ranging from 2.0x10(16) to 2.0x10(17) ions/cm(2) and subsequently thermally annealed at 800 degrees C for 30min. The morphological change of the samples with the increase of implantation dose was investigated using atomic force microscopy (AFM). It was found that oblate-shaped blisters with an average height around 4.0nm were found on the 2.0 x 10(16) ions /cm(2) implanted sample surface; spherical-shaped blisters with an average height wound 10.0nm were found on the 5.0 x 10(16) ions/cm(2) implanted sample surface; strip-shaped and conical cracks were observed on the sample He-implanted to a dose of 1.0 X 10(17) ions /cm(2). Exfoliations occurred on the sample surface to a dose of 2.0 x10(17) ions /cm(2). Mechanisms underlying the surface change were discussed.