8 resultados para Power transactions

em Universidad Politécnica de Madrid


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The efficiency of power optimization tools depends on information on design power provided by the power estimation models. Power models targeting different power groups can enable fast identification of the most power consuming parts of design and their properties. The accuracy of these estimation models is highly dependent on the accuracy of the method used for their characterization. The highest precision is achieved by using physical onboard measurements. In this paper, we present a measurement methodology that is primarily aimed at calibrating and validating high-level dynamic power estimation models. The measurements have been carefully designed to enable the separation of the interconnect power from the logic power and the power of the clock circuitry, so that each of these power groups can be used for the corresponding model validation. The standard measurement uncertainty is lower than 2% of the measured value even with a very small number of repeated measurements. Additionally, the accuracy of a commercial low-level power estimation tool has been also assessed for comparison purposes. The results indicate that the tool is not suitable for power estimation of data path-oriented designs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The growth of wind power as an electric energy source is profitable from an environmental point of view and improves the energetic independence of countries with little fossil fuel resources. However, the wind resource randomness poses a great challenge in the management of electric grids. This study raises the possibility of using hydrogen as a mean to damp the variability of the wind resource. Thus, it is proposed the use of all the energy produced by a typical wind farm for hydrogen generation, that will in turn be used after for suitable generation of electric energy according to the operation rules in a liberalized electric market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an envelope amplifier solution for envelope elimination and restoration (EER), that consists of a series combination of a switch-mode power supply (SMPS), based on three-level voltage cells and a linear regulator. This cell topology offers several advantages over a previously presented envelope amplifier based on a different multilevel topology (two-level voltage cells). The topology of the multilevel converter affects to the whole design of the envelope amplifier and a comparison between both design alternatives regarding the size, complexity and the efficiency of the solution is done. Both envelope amplifier solutions have a bandwidth of 2 MHz with an instantaneous maximum power of 50 W. It is also analyzed the linearity of the three-level cell solution, with critical importance in the EER technique implementation. Additionally, considerations to optimize the design of the envelope amplifier and experimental comparison between both cell topologies are included.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deorbit, power generation, and thrusting performances of a bare thin-tape tether and an insulated tether with a spherical electron collector are compared for typical conditions in low-Earth orbit and common values of length L = 4−20 km and cross-sectional area of the tether A = 1−5 mm2. The relative performance of moderately large spheres, as compared with bare tapes, improves but still lags as one moves from deorbiting to power generation and to thrusting: Maximum drag in deorbiting requires maximum current and, thus, fully reflects on anodic collection capability, whereas extracting power at a load or using a supply to push current against the motional field requires reduced currents. The relative performance also improves as one moves to smaller A, which makes the sphere approach the limiting short-circuit current, and at greater L, with the higher bias only affecting moderately the already large bare-tape current. For a 4-m-diameter sphere, relative performances range from 0.09 sphere-to-bare tether drag ratio for L = 4 km and A = 5 mm2 to 0.82 thrust–efficiency ratio for L = 20 km and A = 1 mm2. Extremely large spheres collecting the short-circuit current at zero bias at daytime (diameters being about 14 m for A = 1 mm2 and 31 m for A = 5 mm2) barely outperform the bare tape for L = 4 km and are still outperformed by the bare tape for L = 20 km in both deorbiting and power generation; these large spheres perform like the bare tape in thrusting. In no case was sphere or sphere-related hardware taken into account in evaluating system mass, which would have reduced the sphere performances even further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of power and time conditions of in situ N2 plasma treatment, prior to silicon nitride (SiN) passivation, were investigated on an AlGaN/GaN high-electron mobility transistor (HEMT). These studies reveal that N2 plasma power is a critical parameter to control the SiN/AlGaN interface quality, which directly affects the 2-D electron gas density. Significant enhancement in the HEMT characteristics was observed by using a low power N2 plasma pretreatment. In contrast, a marked gradual reduction in the maximum drain-source current density (IDS max) and maximum transconductance (gm max), as well as in fT and fmax, was observed as the N2 plasma power increases (up to 40% decrease for 210 W). Different mechanisms were proposed to be dominant as a function of the discharge power range. A good correlation was observed between the device electrical characteristics and the surface assessment by atomic force microscopy and Kelvin force microscopy techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The price formation of the Iberian Energy Derivatives Market-the power futures market-starting in July 2006, is assessed until November 2011, through the evolution of the difference between forward and spot prices in the delivery period (“ex-post forward risk premium”) and the comparison with the forward generation costs from natural gas (“clean spark spread”). The premium tends to be positive in all existing mechanisms (futures, Over-the-Counter and auctions for catering part of the last resort supplies). Since year 2011, the values are smaller due to regulatorily recognized prices for coal power plants. The power futures are strongly correlated with European gas prices. The spreads built with prompt contracts tend also to be positive. The biggest ones are for the month contract, followed by the quarter contract and then by the year contract. Therefore, gas fired generation companies can maximize profits trading with contracts of shorter maturity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless power transfer (WPT) is an emerging technology with an increasing number of potential applications to transfer power from a transmitter to a mobile receiver over a relatively large air gap. However, its widespread application is hampered due to the relatively low efficiency of current Wireless power transfer (WPT) systems. This study presents a concept to maximize the efficiency as well as to increase the amount of extractable power of a WPT system operating in nonresonant operation. The proposed method is based on actively modifying the equivalent secondary-side load impedance by controlling the phase-shift of the active rectifier and its output voltage level. The presented hardware prototype represents a complete wireless charging system, including a dc-dc converter which is used to charge a battery at the output of the system. Experimental results are shown for the proposed concept in comparison to a conventional synchronous rectification approach. The presented optimization method clearly outperforms state-of-the-art solutions in terms of efficiency and extractable power.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On-line partial discharge (PD) measurements have become a common technique for assessing the insulation condition of installed high voltage (HV) insulated cables. When on-line tests are performed in noisy environments, or when more than one source of pulse-shaped signals are present in a cable system, it is difficult to perform accurate diagnoses. In these cases, an adequate selection of the non-conventional measuring technique and the implementation of effective signal processing tools are essential for a correct evaluation of the insulation degradation. Once a specific noise rejection filter is applied, many signals can be identified as potential PD pulses, therefore, a classification tool to discriminate the PD sources involved is required. This paper proposes an efficient method for the classification of PD signals and pulse-type noise interferences measured in power cables with HFCT sensors. By using a signal feature generation algorithm, representative parameters associated to the waveform of each pulse acquired are calculated so that they can be separated in different clusters. The efficiency of the clustering technique proposed is demonstrated through an example with three different PD sources and several pulse-shaped interferences measured simultaneously in a cable system with a high frequency current transformer (HFCT).