10 resultados para ARMATURE WINDINGS
em Universidad Politécnica de Madrid
Resumo:
Transformers with parallel windings are commonly used to reduce the losses in the windings. Windings losses depend on the winding positioning and the frequency effects because each winding affects the current sharing of itself and the neighboring windings. In this paper a methodology for determining the connections of the parallel windings that reduces the power losses (and temperature) in the windings of multi-winding transformers is presented. Other applications of the method, such as balanced current sharing and voltage drop reduction are also explored. In this paper a methodology for determining the connections of the parallel windings that reduces the power losses (and temperature) in the windings of multi-winding transformers is presented. Other applications of the method, such as balanced current sharing and voltage drop reduction are also explored.
Resumo:
In this paper, the applicability of the FRA technique is discussed as a method for detecting inter-turn faults in stator windings. Firstly, this method is tested in an individual medium-voltage stator coil with satisfactory results. Secondly, the tests are extended to a medium-voltage induction motor stator winding, in which inter-turn faults are performed in every coil end of one phase. Results of the frequency response in case of inter-turn faults are evaluated in both cases for different fault resistance values. The experimental setup is also described for each experiment. The results of the application of this technique to the detection of inter-turn faults justify further research in optimizing this technique for preventive maintenance.
Resumo:
This paper presents a microinverter to be integrated into a solar module. The proposed solution combines a forward converter and a constant off-time boundary mode control, providing MPPT capability and unity power factor in a single-stage converter. The transformer structure of the power stage remains as in the classical DC-DC forward converter. Transformer primary windings are utilized for power transfer or demagnetization depending on the grid semi-cycle. Furthermore, bidirectional switches are used on the secondary side allowing direct connection of the inverter to the grid. Design considerations for the proposed solution are provided, regarding the inductance value, transformer turns ratio and frequency variation during a line semi-cycle. The decoupling of the twice the line frequency power pulsation is also discussed, as well as the maximum power point tracking (MPPT) capability. Simulation and experimental results for a 100W prototype are enclosed
Finite Element Analysis Model of a Contactless Transformer for Battery Chargers in Electric Vehicles
Resumo:
A contactless transformer model is proposed in this paper using Finite Element Analysis (FEA). This model can be used to simulate Inductive Coupling Power Transfer (ICPT) systems with good accuracy of the transformer and reduce the fabrication time of these systems. The model not only takes into account the geometry of the windings but also the frequency effects in them. As the transformer does not have a magnetic core, it is complicated to model because the flux is expanded in the area around the windings. In order to obtain a very accurate model, it is necessary to use a 2D/3D field solver.
Resumo:
A modified winding layout for three-phase transformers with PCB windings is proposed in this paper. This modified layout can be used in high current transformers with many PCB layers to simplify the fabrication process. One of the key factors that might increase the cost and complexity in the construction of planar transformers is the number of layers of each PCB winding. This issue becomes even more important in medium-high power three-phase transformers, where the number of PCB layers is higher. In addition to that, the proposed method allows the use of commercial core shapes that are commonly used to design single-phase transformers. This fact makes possible the reduction of cost and flexibility of the design solutions. The proposed solution has been validated and compared using the conventional and the proposed methodologies to design a high power (20 kW) transformer.
Resumo:
Las fuentes de alimentación de modo conmutado (SMPS en sus siglas en inglés) se utilizan ampliamente en una gran variedad de aplicaciones. La tarea más difícil para los diseñadores de SMPS consiste en lograr simultáneamente la operación del convertidor con alto rendimiento y alta densidad de energía. El tamaño y el peso de un convertidor de potencia está dominado por los componentes pasivos, ya que estos elementos son normalmente más grandes y más pesados que otros elementos en el circuito. Para una potencia de salida dada, la cantidad de energía almacenada en el convertidor que ha de ser entregada a la carga en cada ciclo de conmutación, es inversamente proporcional a la frecuencia de conmutación del convertidor. Por lo tanto, el aumento de la frecuencia de conmutación se considera un medio para lograr soluciones más compactas con los niveles de densidad de potencia más altos. La importancia de investigar en el rango de alta frecuencia de conmutación radica en todos los beneficios que se pueden lograr: además de la reducción en el tamaño de los componentes pasivos, el aumento de la frecuencia de conmutación puede mejorar significativamente prestaciones dinámicas de convertidores de potencia. Almacenamiento de energía pequeña y el período de conmutación corto conducen a una respuesta transitoria del convertidor más rápida en presencia de las variaciones de la tensión de entrada o de la carga. Las limitaciones más importantes del incremento de la frecuencia de conmutación se relacionan con mayores pérdidas del núcleo magnético convencional, así como las pérdidas de los devanados debido a los efectos pelicular y proximidad. También, un problema potencial es el aumento de los efectos de los elementos parásitos de los componentes magnéticos - inductancia de dispersión y la capacidad entre los devanados - que causan pérdidas adicionales debido a las corrientes no deseadas. Otro factor limitante supone el incremento de las pérdidas de conmutación y el aumento de la influencia de los elementos parásitos (pistas de circuitos impresos, interconexiones y empaquetado) en el comportamiento del circuito. El uso de topologías resonantes puede abordar estos problemas mediante el uso de las técnicas de conmutaciones suaves para reducir las pérdidas de conmutación incorporando los parásitos en los elementos del circuito. Sin embargo, las mejoras de rendimiento se reducen significativamente debido a las corrientes circulantes cuando el convertidor opera fuera de las condiciones de funcionamiento nominales. A medida que la tensión de entrada o la carga cambian las corrientes circulantes incrementan en comparación con aquellos en condiciones de funcionamiento nominales. Se pueden obtener muchos beneficios potenciales de la operación de convertidores resonantes a más alta frecuencia si se emplean en aplicaciones con condiciones de tensión de entrada favorables como las que se encuentran en las arquitecturas de potencia distribuidas. La regulación de la carga y en particular la regulación de la tensión de entrada reducen tanto la densidad de potencia del convertidor como el rendimiento. Debido a la relativamente constante tensión de bus que se encuentra en arquitecturas de potencia distribuidas los convertidores resonantes son adecuados para el uso en convertidores de tipo bus (transformadores cc/cc de estado sólido). En el mercado ya están disponibles productos comerciales de transformadores cc/cc de dos puertos que tienen muy alta densidad de potencia y alto rendimiento se basan en convertidor resonante serie que opera justo en la frecuencia de resonancia y en el orden de los megahercios. Sin embargo, las mejoras futuras en el rendimiento de las arquitecturas de potencia se esperan que vengan del uso de dos o más buses de distribución de baja tensión en vez de una sola. Teniendo eso en cuenta, el objetivo principal de esta tesis es aplicar el concepto del convertidor resonante serie que funciona en su punto óptimo en un nuevo transformador cc/cc bidireccional de puertos múltiples para atender las necesidades futuras de las arquitecturas de potencia. El nuevo transformador cc/cc bidireccional de puertos múltiples se basa en la topología de convertidor resonante serie y reduce a sólo uno el número de componentes magnéticos. Conmutaciones suaves de los interruptores hacen que sea posible la operación en las altas frecuencias de conmutación para alcanzar altas densidades de potencia. Los problemas posibles con respecto a inductancias parásitas se eliminan, ya que se absorben en los Resumen elementos del circuito. El convertidor se caracteriza con una muy buena regulación de la carga propia y cruzada debido a sus pequeñas impedancias de salida intrínsecas. El transformador cc/cc de puertos múltiples opera a una frecuencia de conmutación fija y sin regulación de la tensión de entrada. En esta tesis se analiza de forma teórica y en profundidad el funcionamiento y el diseño de la topología y del transformador, modelándolos en detalle para poder optimizar su diseño. Los resultados experimentales obtenidos se corresponden con gran exactitud a aquellos proporcionados por los modelos. El efecto de los elementos parásitos son críticos y afectan a diferentes aspectos del convertidor, regulación de la tensión de salida, pérdidas de conducción, regulación cruzada, etc. También se obtienen los criterios de diseño para seleccionar los valores de los condensadores de resonancia para lograr diferentes objetivos de diseño, tales como pérdidas de conducción mínimas, la eliminación de la regulación cruzada o conmutación en apagado con corriente cero en plena carga de todos los puentes secundarios. Las conmutaciones en encendido con tensión cero en todos los interruptores se consiguen ajustando el entrehierro para obtener una inductancia magnetizante finita en el transformador. Se propone, además, un cambio en los señales de disparo para conseguir que la operación con conmutaciones en apagado con corriente cero de todos los puentes secundarios sea independiente de la variación de la carga y de las tolerancias de los condensadores resonantes. La viabilidad de la topología propuesta se verifica a través una extensa tarea de simulación y el trabajo experimental. La optimización del diseño del transformador de alta frecuencia también se aborda en este trabajo, ya que es el componente más voluminoso en el convertidor. El impacto de de la duración del tiempo muerto y el tamaño del entrehierro en el rendimiento del convertidor se analizan en un ejemplo de diseño de transformador cc/cc de tres puertos y cientos de vatios de potencia. En la parte final de esta investigación se considera la implementación y el análisis de las prestaciones de un transformador cc/cc de cuatro puertos para una aplicación de muy baja tensión y de decenas de vatios de potencia, y sin requisitos de aislamiento. Abstract Recently, switch mode power supplies (SMPS) have been used in a great variety of applications. The most challenging issue for designers of SMPS is to achieve simultaneously high efficiency operation at high power density. The size and weight of a power converter is dominated by the passive components since these elements are normally larger and heavier than other elements in the circuit. If the output power is constant, the stored amount of energy in the converter which is to be delivered to the load in each switching cycle is inversely proportional to the converter’s switching frequency. Therefore, increasing the switching frequency is considered a mean to achieve more compact solutions at higher power density levels. The importance of investigation in high switching frequency range comes from all the benefits that can be achieved. Besides the reduction in size of passive components, increasing switching frequency can significantly improve dynamic performances of power converters. Small energy storage and short switching period lead to faster transient response of the converter against the input voltage and load variations. The most important limitations for pushing up the switching frequency are related to increased conventional magnetic core loss as well as the winding loss due to the skin and proximity effect. A potential problem is also increased magnetic parasitics – leakage inductance and capacitance between the windings – that cause additional loss due to unwanted currents. Higher switching loss and the increased influence of printed circuit boards, interconnections and packaging on circuit behavior is another limiting factor. Resonant power conversion can address these problems by using soft switching techniques to reduce switching loss incorporating the parasitics into the circuit elements. However the performance gains are significantly reduced due to the circulating currents when the converter operates out of the nominal operating conditions. As the input voltage or the load change the circulating currents become higher comparing to those ones at nominal operating conditions. Multiple Input-Output Many potential gains from operating resonant converters at higher switching frequency can be obtained if they are employed in applications with favorable input voltage conditions such as those found in distributed power architectures. Load and particularly input voltage regulation reduce a converter’s power density and efficiency. Due to a relatively constant bus voltage in distributed power architectures the resonant converters are suitable for bus voltage conversion (dc/dc or solid state transformation). Unregulated two port dc/dc transformer products achieving very high power density and efficiency figures are based on series resonant converter operating just at the resonant frequency and operating in the megahertz range are already available in the market. However, further efficiency improvements of power architectures are expected to come from using two or more separate low voltage distribution buses instead of a single one. The principal objective of this dissertation is to implement the concept of the series resonant converter operating at its optimum point into a novel bidirectional multiple port dc/dc transformer to address the future needs of power architectures. The new multiple port dc/dc transformer is based on a series resonant converter topology and reduces to only one the number of magnetic components. Soft switching commutations make possible high switching frequencies to be adopted and high power densities to be achieved. Possible problems regarding stray inductances are eliminated since they are absorbed into the circuit elements. The converter features very good inherent load and cross regulation due to the small output impedances. The proposed multiple port dc/dc transformer operates at fixed switching frequency without line regulation. Extensive theoretical analysis of the topology and modeling in details are provided in order to compare with the experimental results. The relationships that show how the output voltage regulation and conduction losses are affected by the circuit parasitics are derived. The methods to select the resonant capacitor values to achieve different design goals such as minimum conduction losses, elimination of cross regulation or ZCS operation at full load of all the secondary side bridges are discussed. ZVS turn-on of all the switches is achieved by relying on the finite magnetizing inductance of the Abstract transformer. A change of the driving pattern is proposed to achieve ZCS operation of all the secondary side bridges independent on load variations or resonant capacitor tolerances. The feasibility of the proposed topology is verified through extensive simulation and experimental work. The optimization of the high frequency transformer design is also addressed in this work since it is the most bulky component in the converter. The impact of dead time interval and the gap size on the overall converter efficiency is analyzed on the design example of the three port dc/dc transformer of several hundreds of watts of the output power for high voltage applications. The final part of this research considers the implementation and performance analysis of the four port dc/dc transformer in a low voltage application of tens of watts of the output power and without isolation requirements.
Resumo:
The generator differential protection is one of the most important electrical protections of synchronous generator stator windings. Its operation principle is based on the comparison of the input current and output current at each phase winding. Unwanted trip commands are usually caused by CT saturation, wrong CT selection, or the fact that they may come from different manufacturers. In generators grounded through high impedance, only phase-to-phase or three-phase faults can be detected by the differential protection. This kind of fault causes differential current to flow in, at least, two phases of the winding. Several cases of unwanted trip commands caused by the appearance of differential current in only one phase of the generator have been reported. In this paper multi-phase criterion is proposed for generator differential protection algorithm when applied to high impedance grounded generators.
New On-Line Excitation-System Ground Fault Location Method Tested in a 106 MVA Synchronous Generator
Resumo:
In this paper, a novel excitation-system ground-fault location method is described and tested in a 106 MVA synchronous machine. In this unit, numerous rotor ground-fault trips took place always about an hour after the synchronization to the network. However, when the field winding insulation was checked after the trips, there was no failure. The data indicated that the faults in the rotor were caused by centrifugal forces and temperature. Unexpectedly, by applying this new method, the failure was located in a cable between the excitation transformer and the automatic voltage regulator. In addition, several intentional ground faults were performed along the field winding with different fault resistance values, in order to test the accuracy of this method to locate defects in rotor windings of large generators. Therefore, this new on-line rotor ground-fault detection algorithm is tested in high-power synchronous generators with satisfactory results.
Resumo:
Uno de los defectos más frecuentes en los generadores síncronos son los defectos a tierra tanto en el devanado estatórico, como de excitación. Se produce un defecto cuando el aislamiento eléctrico entre las partes activas de cualquiera de estos devanados y tierra se reduce considerablemente o desaparece. La detección de los defectos a tierra en ambos devanados es un tema ampliamente estudiado a nivel industrial. Tras la detección y confirmación de la existencia del defecto, dicha falta debe ser localizada a lo largo del devanado para su reparación, para lo que habitualmente el rotor debe ser extraído del estator. Esta operación resulta especialmente compleja y cara. Además, el hecho de limitar la corriente de defecto en ambos devanados provoca que el defecto no sea localizable visualmente, pues apenas existe daño en el generador. Por ello, se deben aplicar técnicas muy laboriosas para localizar exactamente el defecto y poder así reparar el devanado. De cara a reducir el tiempo de reparación, y con ello el tiempo en que el generador esta fuera de servicio, cualquier información por parte del relé de protección acerca de la localización del defecto resultaría de gran utilidad. El principal objetivo de esta tesis doctoral ha sido el desarrollo de nuevos algoritmos que permitan la estimación de la localización de los defectos a tierra tanto en el devanado rotórico como estatórico de máquinas síncronas. Respecto al devanado de excitación, se ha presentado un nuevo método de localización de defectos a tierra para generadores con excitación estática. Este método permite incluso distinguir si el defecto se ha producido en el devanado de excitación, o en cualquiera de los componentes del sistema de excitación, esto es, transformador de excitación, conductores de alimentación del rectificador controlado, etc. En caso de defecto a tierra en del devanado rotórico, este método proporciona una estimación de su localización. Sin embargo, para poder obtener la localización del defecto, se precisa conocer el valor de resistencia de defecto. Por ello, en este trabajo se presenta además un nuevo método para la estimación de este parámetro de forma precisa. Finalmente, se presenta un nuevo método de detección de defectos a tierra, basado en el criterio direccional, que complementa el método de localización, permitiendo tener en cuenta la influencia de las capacidades a tierra del sistema. Estas capacidades resultan determinantes a la hora de localizar el defecto de forma adecuada. En relación con el devanado estatórico, en esta tesis doctoral se presenta un nuevo algoritmo de localización de defectos a tierra para generadores que dispongan de la protección de faltas a tierra basada en la inyección de baja frecuencia. Se ha propuesto un método general, que tiene en cuenta todos los parámetros del sistema, así como una versión simplificada del método para generadores con capacidades a tierra muy reducida, que podría resultar de fácil implementación en relés de protección comercial. Los algoritmos y métodos presentados se han validado mediante ensayos experimentales en un generador de laboratorio de 5 kVA, así como en un generador comercial de 106 MVA con resultados satisfactorios y prometedores. ABSTRACT One of the most common faults in synchronous generators is the ground fault in both the stator winding and the excitation winding. In case of fault, the insulation level between the active part of any of these windings and ground lowers considerably, or even disappears. The detection of ground faults in both windings is a very researched topic. The fault current is typically limited intentionally to a reduced level. This allows to detect easily the ground faults, and therefore to avoid damage in the generator. After the detection and confirmation of the existence of a ground fault, it should be located along the winding in order to repair of the machine. Then, the rotor has to be extracted, which is a very complex and expensive operation. Moreover, the fact of limiting the fault current makes that the insulation failure is not visually detectable, because there is no visible damage in the generator. Therefore, some laborious techniques have to apply to locate accurately the fault. In order to reduce the repair time, and therefore the time that the generator is out of service, any information about the approximate location of the fault would be very useful. The main objective of this doctoral thesis has been the development of new algorithms and methods to estimate the location of ground faults in the stator and in the rotor winding of synchronous generators. Regarding the excitation winding, a new location method of ground faults in excitation winding of synchronous machines with static excitation has been presented. This method allows even to detect if the fault is at the excitation winding, or in any other component of the excitation system: controlled rectifier, excitation transformer, etc. In case of ground fault in the rotor winding, this method provides an estimation of the fault location. However, in order to calculate the location, the value of fault resistance is necessary. Therefore, a new fault-resistance estimation algorithm is presented in this text. Finally, a new fault detection algorithm based on directional criterion is described to complement the fault location method. This algorithm takes into account the influence of the capacitance-to-ground of the system, which has a remarkable impact in the accuracy of the fault location. Regarding the stator winding, a new fault-location algorithm has been presented for stator winding of synchronous generators. This algorithm is applicable to generators with ground-fault protection based in low-frequency injection. A general algorithm, which takes every parameter of the system into account, has been presented. Moreover, a simplified version of the algorithm has been proposed for generators with especially low value of capacitance to ground. This simplified algorithm might be easily implementable in protective relays. The proposed methods and algorithms have been tested in a 5 kVA laboratory generator, as well as in a 106 MVA synchronous generator with satisfactory and promising results.
Resumo:
Frequency Response Analysis is a well-known technique for the diagnosis of power transformers. Currently, this technique is under research for its application in rotary electrical machines. This paper presents significant results on the application of Frequency Response Analysis to fault detection in field winding of synchronous machines with static excitation. First, the influence of the rotor position on the frequency response is evaluated. Secondly, some relevant test results are shown regarding ground fault and inter-turn fault detection in field windings at standstill condition. The influence of the fault resistance value is also taken into account. This paper also studies the applicability of Frequency Response Analysis in fault detection in field windings while rotating. This represents an important feature because some defects only appear with the machine rated speed. Several laboratory test results show the applicability of this fault detection technique in field windings at full speed with no excitation current.