Evaluation of the applicability of FRA for inter-turn fault detection in stator windings
Data(s) |
2013
|
---|---|
Resumo |
In this paper, the applicability of the FRA technique is discussed as a method for detecting inter-turn faults in stator windings. Firstly, this method is tested in an individual medium-voltage stator coil with satisfactory results. Secondly, the tests are extended to a medium-voltage induction motor stator winding, in which inter-turn faults are performed in every coil end of one phase. Results of the frequency response in case of inter-turn faults are evaluated in both cases for different fault resistance values. The experimental setup is also described for each experiment. The results of the application of this technique to the detection of inter-turn faults justify further research in optimizing this technique for preventive maintenance. |
Formato |
application/pdf |
Identificador | |
Idioma(s) |
eng |
Publicador |
E.T.S.I. Industriales (UPM) |
Relação |
http://oa.upm.es/29642/1/INVE_MEM_2013_170377.pdf info:eu-repo/semantics/altIdentifier/doi/10.1109/DEMPED.2013.6645714 |
Direitos |
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ info:eu-repo/semantics/restrictedAccess |
Fonte |
Proceedings 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives | 2013 9th IEEE International Symposium on | 27/08/2013 - 30/08/2013 | Valencia, España |
Palavras-Chave | #Energía Eléctrica |
Tipo |
info:eu-repo/semantics/conferenceObject Ponencia en Congreso o Jornada NonPeerReviewed |