893 resultados para spot tests
Resumo:
The add protection effect promoted by traces of PdCl2 in [Ni(dmgH)(2)] spot tests was elucidated from confocal Raman microscopy imaging, which revealed the formation of protecting layers of [Pd(dmgH)(2)] closing the extremities of the [Ni(dmgH)(2)] filaments.
Resumo:
Fritz Feigl's scientific legacy of more than 500 original publications of spot reactions and new chemical concepts, includes a precise definition of identification limit, the difference between specific and selective reactions, and the masking/demasking of chemical reactions, the selective functionalization for the development of new reactions. It resulted in a considerable and varied number of new applications evident in hundreds of citations of his publications, up to 2003, throughout the thirty years following his passing away, and comprehending scientific as well as commercial fields, like that of kits for exploratory tests, based on his reactions and of his followers.
Resumo:
Brumadoite, ideally Cu(2)Te(6+)O(4)(OH)(4)center dot 5H(2)O, is a new mineral from Pedra Preta mine, Serra das Eguas, Brumado, Bahia, Brazil. It occurs as microcrystalline aggregates both on and, rarely, pseudomorphous after coarse-grained magnesite, associated with mottramite and quartz. Crystals are platy, subhedral, 1-2 mu m in size. Brumadoite is blue (near RHS 114B), has a pale blue streak and a vitreous lustre. It is transparent to translucent and does not fluoresce. The empirical formula is (Cu(2.90)Pb(0.04)Ca(0.01))(Sigma 2.95) (Te(0.93)(6+)Si(0.05))(Sigma 0.98)O(3.92)(OH)(3.84)center dot 5.24H(2)O. Infrared spectra clearly show both (OH) and H(2)O. Microchemical spot tests using a KI Solution show that brumadoite has tellurium in the 6(+) state. The mineral is monoclinic, P2(1)/m or P2(1). Unit-cell parameters refined from X-ray powder data are a 8.629(2) angstrom, b 5.805(2) angstrom, c 7.654(2) angstrom, beta 103.17(2)degrees, V 373.3(2) angstrom(3), Z = 2. The eight strongest X-ray powder-diffraction lines [d in angstrom, (l),(hkl)] are: 8.432,(100),(100); 3.162,(66),((2) over bar 02); 2.385,(27),(220); 2.291,((1) over bar 12),(22); 1.916,(11),(312); 1.666,(14),((4) over bar 22,114); 1.452,(10), (323, 040); 1.450,(10),(422,403). The name is for the type locality, Brumado, Bahia, Brazil. The new mineral species has been approved by the CNMNC (IMA 2008-028).
Sistema inteligente para detecção de manchas de óleo na superfície marinha através de imagens de SAR
Resumo:
Oil spill on the sea, accidental or not, generates enormous negative consequences for the affected area. The damages are ambient and economic, mainly with the proximity of these spots of preservation areas and/or coastal zones. The development of automatic techniques for identification of oil spots on the sea surface, captured through Radar images, assist in a complete monitoring of the oceans and seas. However spots of different origins can be visualized in this type of imaging, which is a very difficult task. The system proposed in this work, based on techniques of digital image processing and artificial neural network, has the objective to identify the analyzed spot and to discern between oil and other generating phenomena of spot. Tests in functional blocks that compose the proposed system allow the implementation of different algorithms, as well as its detailed and prompt analysis. The algorithms of digital image processing (speckle filtering and gradient), as well as classifier algorithms (Multilayer Perceptron, Radial Basis Function, Support Vector Machine and Committe Machine) are presented and commented.The final performance of the system, with different kind of classifiers, is presented by ROC curve. The true positive rates are considered agreed with the literature about oil slick detection through SAR images presents
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Biológicas (Botânica) - IBB
Resumo:
Water is a common impurity of jet fuel, and can exist in three forms: dissolved in the fuel, as a suspension and as a distinct layer at the bottom of the fuel tank. Water cannot practically be eliminated from fuel but must be kept to a minimum as large quantities can cause engine problems, particularly when frozen, and the interface between water and fuel acts as a breeding ground for biological contaminants. The quantities of dissolved or suspended water are quite small, ranging from about 10 ppm to 150 ppm. This makes the measurement task difficult and there is currently a lack of a convenient, electrically passive system for water-in-fuel monitoring; instead the airlines rely on colorimetric spot tests or simply draining liquid from the bottom of fuel tanks. For all these reason, people have explored different ways to detect water in fuel, however all these approaches have problems, e.g. they may not be electrically passive or they may be sensitive to the refractive index of the fuel. In this paper, we present a simple, direct and sensitive approach involving the use of a polymer optical fibre Bragg grating to detect water in fuel. The principle is that poly(methyl methacrylate) (PMMA) can absorb moisture from its surroundings (up to 2% at 23 °C), leading to both a swelling of the material and an increase in refractive index with a consequent increase in the Bragg wavelength of a grating inscribed in the material.
Resumo:
Water is a common impurity of jet fuel, and can exist in three forms: dissolved in the fuel, as a suspension and as a distinct layer at the bottom of the fuel tank. Water cannot practically be eliminated from fuel but must be kept to a minimum as large quantities can cause engine problems, particularly when frozen, and the interface between water and fuel acts as a breeding ground for biological contaminants. The quantities of dissolved or suspended water are quite small, ranging from about 10 ppm to 150 ppm. This makes the measurement task difficult and there is currently a lack of a convenient, electrically passive system for water-in-fuel monitoring; instead the airlines rely on colorimetric spot tests or simply draining liquid from the bottom of fuel tanks. For all these reason, people have explored different ways to detect water in fuel, however all these approaches have problems, e.g. they may not be electrically passive or they may be sensitive to the refractive index of the fuel. In this paper, we present a simple, direct and sensitive approach involving the use of a polymer optical fibre Bragg grating to detect water in fuel. The principle is that poly(methyl methacrylate) (PMMA) can absorb moisture from its surroundings (up to 2% at 23 °C), leading to both a swelling of the material and an increase in refractive index with a consequent increase in the Bragg wavelength of a grating inscribed in the material.
Resumo:
The common bean is affected by several pathogens that can cause severe yield losses. Here we report the introgression of resistance genes to anthracnose, angular leaf spot and rust in the `carioca-type` bean cultivar `Ruda`. Initially, four backcross (BC) lines were obtained using `TO`, `AB 136`, `Ouro Negro` and `AND 277` as donor parents. Molecular fingerprinting was used to select the lines genetically closer to the recurrent parent. The relative genetic distances between `Ruda` and the BC lines varied between 0.0% and 1.99%. The BC lines were intercrossed and molecular markers linked to the resistance genes were used to identify the plants containing the genes of interest. These plants were selfed to obtain the F(2), F(3) and F(4) plants which were selected based on the presence of the molecular markers mentioned and resistance was confirmed in the F(4) generation by inoculation. Four F(4:7) pyramid lines with all the resistance genes showed resistance spectra equivalent to those of their respective donor parents. Yield tests showed that these lines are as productive as the best `carioca-type` cultivars.
Resumo:
Early studies in patients with systemic lupus erythematosus (SLE) reported increased incidence of tuberculosis. The tuberculin skin test (TST) is the technique of choice to detect latent tuberculosis infection (LTBI) but has several limitations. OBJECTIVES We compared TST and the newer T.SPOT.TB test to diagnose LTBI in SLE patients. METHODS In this observational cohort study conducted between August 2009 and February 2012, we recruited 92 patients from those attending the SLE clinic of our university hospital. Data recorded were epidemiological and sociodemographic characteristics. Laboratory analyses included TST and T.SPOT.TB tests. RESULTS Of the patients studied, 92% were women with an average age of 42.7 years. Overall, the degree of correlation between the two tests was low (Kappa index = 0.324) but was better in patients not receiving corticosteroids (CTC)/immunosuppressive (IS) therapy (Kappa = 0.436) and in those receiving hydroxychloroquine (Kappa = 0.473). While TST results were adversely affected by those receiving CTC and/or IS drugs (P = 0.021), the T.SPOT.TB results were not. CONCLUSION Although the TST test remains a useful tool for diagnosing LTBI in SLE patients, the T.SPOT.TB test is perhaps better employed when the patient is receiving CTC and/or IS drugs.
Resumo:
Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.
Resumo:
In the regions of Campinas and Sumaré, São Paulo, Brazil, hidroponically grown crops of Lettuce (Lactuca sativa) cv. Verônica, which showed virus-like symptoms were examined by electron microscope, biological, serological and molecular tests. Pleomorphic, enveloped particles (80-100 nm in diameter) were always detected in these samples. Experimentally inoculated host plants, including lettuce, reacted with tospoviruses-induced symptoms. Some differences were observed in Gomphrena globosa, which reacted by showing local lesions and systemic mosaic. Two isolates of Tomato chlorotic spot virus (TCSV) were identified by DAS-ELISA and by RT-PCR. The sequencing and alignment of the RT-PCR coat protein amplified fragments have indicated a high degree of homology with the TCSV sequences stored in the GenBank. This is the first report of losses due to a virus from the genus Tospovirus in commercial hydroponic lettuce crops in Brazil. Further epidemiological studies are needed for better understanding the spread of the virus in hydroponic crops, since Tomato spotted wilt virus (TSWV) is reported to spread through the nutritive solution.
Resumo:
A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.
Resumo:
Changes in urinary porphyrin excretion may be the result of hereditary causes and/or from environmental or occupational exposure. The objective of this study was to measure the amount of some porphyrins in spot urine samples obtained from volunteers randomly selected from a healthy adult population of São Paulo with a sensitive HPLC method and to estimate normal ranges for a non-exposed population. Spot urine samples were collected from 126 subjects (both genders, 18 to 65 years old) not occupationally exposed to porphyrinogenic agents. Porphyrin fractions were separated on RP-18 HPLC column eluted with a methanol/ammonium acetate buffer gradient, pH 4.0, and measured fluorometrically (excitation 405 nm/emission 620 nm). The amount of porphyrins was corrected for urinary creatinine excretion. Only 8-carboxyl (uro) and 4-carboxyl (copro) porphyrins were quantified as µg/g creatinine. Data regarding age, gender, occupational activities, smoking and drinking habits were analyzed by Mann-Whitney and Kruskal-Wallis tests. Uroporphyrin results did not differ significantly between the subgroups studied. Copro and uro + copro porphyrins were significantly different for smokers (P = 0.008) and occupational activities (P = 0.004). With respect to alcohol consumption, only men drinking >20 g/week showed significant differences in the levels of copro (P = 0.022) and uro + copro porphyrins (P = 0.012). The 2.5-97.5th percentile limit values, excluding those for subjects with an alcohol drinking habit >20 g/week, were 0-20.8, 11.7-93.1, and 15.9-102.9 µg/g creatinine for uro, copro and uro + copro porphyrins, respectively. These percentile limit values can be proposed as a first attempt to provide urinary porphyrin reference values for our population, serving for an early diagnosis of porphyrinopathies or as biomarkers of exposure to porphyrinogenic agents.