944 resultados para small-animal PET


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transgenic mouse models of human cancers represent one of the most promising approaches to elucidate clinically relevant mechanisms of action and provide insights into the treatment efficacy of new antitumor drugs. The use of Trp53 transgenic mice (Trp53 knockout [Trp53(-/-)] mice) for these kinds of studies is, so far, restricted by limitations in detecting developing tumors and the lack of noninvasive tools for monitoring tumor growth, progression, and treatment response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Positron Emission Tomography (PET), bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Small animal fracture models have gained increasing interest in fracture healing studies. To achieve standardized and defined study conditions, various variables must be carefully controlled when designing fracture healing experiments in mice or rats. The strain, age and sex of the animals may influence the process of fracture healing. Furthermore, the choice of the fracture fixation technique depends on the questions addressed, whereby intra- and extramedullary implants as well as open and closed surgical approaches may be considered. During the last few years, a variety of different, highly sophisticated implants for fracture fixation in small animals have been developed. Rigid fixation with locking plates or external fixators results in predominantly intramembranous healing in both mice and rats. Locking plates, external fixators, intramedullary screws, the locking nail and the pin-clip device allow different degrees of stability resulting in various amounts of endochondral and intramembranous healing. The use of common pins that do not provide rotational and axial stability during fracture stabilization should be discouraged in the future. Analyses should include at least biomechanical and histological evaluations, even if the focus of the study is directed towards the elucidation of molecular mechanisms of fracture healing using the largely available spectrum of antibodies and gene-targeted animals to study molecular mechanisms of fracture healing. This review discusses distinct requirements for the experimental setups as well as the advantages and pitfalls of the different fixation techniques in rats and mice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine genital campylobacteriosis (BGC), caused by Campylobacter fetus subsp. venerealis, is associated with production losses in cattle worldwide. This study aimed to develop a reliable BGC guinea pig model to facilitate future studies of pathogenicity, abortion mechanisms and vaccine efficacy. Seven groups of five pregnant guinea pigs (1 control per group) were inoculated with one of three strains via intra-peritoneal (IP) or intra-vaginal routes. Samples were examined using culture, PCR and histology. Abortions ranged from 0 to 100 and re-isolation of causative bacteria from sampled sites varied with strain, dose of bacteria and time to abortion. Histology indicated metritis and placentitis, suggesting that the bacteria induce inflammation, placental detachment and subsequent abortion. Variation of virulence between strains was observed and determined by culture and abortion rates. IP administration of C. fetus subsp. venerealis to pregnant guinea pigs is a promising small animal model for the investigation of BGC abortion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed tomography (CT) is one of the most valuable modalities for in vivo imaging because it is fast, high-resolution, cost-effective, and non-invasive. Moreover, CT is heavily used not only in the clinic (for both diagnostics and treatment planning) but also in preclinical research as micro-CT. Although CT is inherently effective for lung and bone imaging, soft tissue imaging requires the use of contrast agents. For small animal micro-CT, nanoparticle contrast agents are used in order to avoid rapid renal clearance. A variety of nanoparticles have been used for micro-CT imaging, but the majority of research has focused on the use of iodine-containing nanoparticles and gold nanoparticles. Both nanoparticle types can act as highly effective blood pool contrast agents or can be targeted using a wide variety of targeting mechanisms. CT imaging can be further enhanced by adding spectral capabilities to separate multiple co-injected nanoparticles in vivo. Spectral CT, using both energy-integrating and energy-resolving detectors, has been used with multiple contrast agents to enable functional and molecular imaging. This review focuses on new developments for in vivo small animal micro-CT using novel nanoparticle probes applied in preclinical research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preclinical imaging has a critical role in phenotyping, in drug discovery, and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review high-resolution computed tomography (CT) also known as micro-CT for small-animal imaging. We present the principles, the technologies, the image quality parameters, and the types of applications. We show that micro-CT can be used to provide not only morphological but also functional information such as cardiac function or vascular permeability. Another way in which micro-CT can be used in the study of both function and anatomy is by combining it with other imaging modalities, such as positron emission tomography or single-photon emission tomography. Compared to other modalities, micro-CT imaging is usually regarded as being able to provide higher throughput at lower cost and higher resolution. The limitations are usually associated with the relatively poor contrast mechanisms and the radiation damage, although the use of novel nanoparticle-based contrast agents and careful design of studies can address these limitations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated a modification of the rat-pin model to enable testing of bone substitute materials. The model was characterized using the ceramic, beta-tricalcium phosphate (betaTCP) as a filler.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiation biology is being transformed by the implementation of small animal image-guided precision radiotherapy into pre-clinical research programmes worldwide. We report on the current status and developments of the small animal radiotherapy field, suggest criteria for the design and execution of effective studies and contend that this powerful emerging technology, used in combination with relevant small animal models, holds much promise for translational impact in radiation oncology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Für diese Arbeit wurden sechs neue Benzodiazepinderivate, TC07, TC08, TC09, TC10, TC11 und TC12, hergestellt. Diese wurden mittels Radioligandenbindungsassay sowohl auf ihre Bindungseigenschaften für Membranen des Cerebellum, des Hippo-campus und des Cortex der Ratte hin untersucht, als auch für Membranen von HEK293 Zellen, die transient rekombinante GABAA Rezeptoren exprimierten. Zusätz-lich wurden kompetitive in situ Rezeptorautoradiographien an Rattenhirnschnitten mit den Liganden [3H]Ro15-4513 und [3H]R015-1788 durchgeführt. Zusammen ergaben sich aus diesen Experimenten deutliche Hinweise auf eine Selektivität der Verbindun-gen TC07, TC11 und TC12 für a5-Untereinheiten enthaltende GABAA Rezeptoren mit a5-Affinitäten im niedrigen nanomolaren Bereich. In vivo Bindungsexperimente in Ratten, mit [3H]Ro15-1788 als Tracer und TC07 als Kompetitor, ergaben, dass TC07 mehr [3H]Ro15-1788 im Vorderhirn als im Cerebellum verdrängt. Bezog man die regionale Verteilung der a5-Untereinheit des GABAA Rezep-tors im Rattenhirn mit ein – sehr wenige a5-Untereinheiten im Cerebellum, etwa 20 % der GABAA Rezeptor-Untereinheiten im Hippocampus – untermauerten diese Ergeb-nisse die Vermutung, TC07 könne a5-selektiv sein. Diese Daten bestätigten darü-berhinaus, dass TC07 die Blut-Hirn-Schranke passieren kann. Für elektrophysiologische Messungen mit TC07 und TC12 wurden die oben erwähnten transient transfizierten HEK293 Zellen verwendet, welche die GABAA Rezeptor Unte-reinheitenkombination a5b3g2 exprimierten. Das Dosis-Antwort Verhalten ergab keinen signifikanten Effekt für TC12. Die Daten von TC07 dagegen lassen auf einen schwach negativ modulatorischen Effekt schließen, was, zumindest theoretisch, die Möglichkeit eröffnet, TC07 auch als sogenannten cognitive enhancer einzusetzen. Der errechnete Ki-Wert lag in derselben Größenordnung wie der Ki-Wert, der anhand der Bindungsas-saydaten errechnet wurde. Insgesamt rechtfertigen die bisherigen Ergebnisse die radiochemische Markierung mit 18F von drei der sechs getesteten Verbindungen in der Reihenfolge TC07, TC12 und TC11. Des Weiteren wurde [18F]MHMZ, ein potentiell 5-HT2A selektiver Ligand und PET-Tracer einschließlich Vorläufer und Referenzverbindungen, mit hohen Ausbeuten syn-thetisiert (Herth, Debus et al. 2008). Autoradiographieexperimente mit Rattenhirn-schnitten zeigten hervorragende in situ Bindungseigenschaften der neuen Verbindung. Die Daten wiesen eine hohe Selektivität für 5-HT2A Rezeptoren in Verbindung mit einer niedrigen unspezifischen Bindung auf. [18F]MHMZ erfährt in vivo eine schnelle Metabo-lisierung, wobei ein polarer aktiver Metabolit entsteht, welcher vermutlich nicht die Blut-Hirn-Schranke passieren kann. Transversale, sagittale und coronale Kleintier-PET-Bilder des Rattenhirns zeigten eine hohe Anreicherung im frontalen Cortex und im Striatum, während im Cerebellum so gut wie keine Anreicherung festzustellen war. Diese Verteilung deckt sich mit der bekann-ten Verteilung der 5-HT2A Rezeptoren. Die in vivo Anreicherung scheint sich ebenfalls gut mit der Verteilung der in den Autoradiographieexperimenten gemessenen Bindung zu decken. Nach Berechnungen mit dem 4-Parameter Referenzgewebe Modell beträgt das Bindungspotential (BP) für den frontalen Cortex 1,45. Das Cortex zu Cerebellum Verhältnis wurde auf 2,7 nach 30 Minuten Messzeit bestimmt, was bemerkenswert nah an den von Lundkvist et al. für [11C]MDL 100907 publizierten Daten liegt. Abgesehen von der etwas niedrigeren Affinität waren die gemessenen in vitro, in situ und in vivo Daten denen von [3H]MDL 100907 und [11C]MDL 100907 sehr ähnlich, so dass wir ein [18F]Analogon in der Hand haben, das die bessere Selektivität von MDL 100907 verglichen mit Altanserin mit der längeren Halbwertszeit und den besse-ren Eigenschaften für die klinische Routine von 18F verglichen mit 11C verbindet. Die Ergebnisse von [18F]MHMZ rechtfertigenden weitere Experimente, um diesen Liganden für die klinische Routine am Menschen nutzbar zu machen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Folic acid, also known as vitamin B9, is the oxidized form of 5,6,7,8-tetrahydrofolate, which serves as methyl- or methylene donor (C1-building blocks) during DNA synthesis. Under physiological conditions the required amount of 5,6,7,8-tetrahydrofolate for survival of the cell is accomplished through the reduced folate carrier (RFC). In contrast, the supply of 5,6,7,8-tetrahydrofolate is insufficient under pathophysiological conditions of tumors due to an increased proliferation rate. Consequently, many tumor cells exhibit an (over)expression of the folate receptor. This phenomenon has been applied to diagnostics (PET, SPECT, MR) to image FR-positive tumors and on the other hand to treat malignancies related to a FR (over)expression. Based on this concept, a new 18F-labeled folate for PET imaging has been developed and was evaluated in vivo using tumor-bearing mice. The incorporation of oligoethylene spacers into the molecular structure led to a significant enhancement of the pharmacokinetics in comparison to previously developed 18F-folates. The liver uptake could be reduced by one sixth by remaining a tumor uptake of 3%ID/g leading to better contrast ratios. Encouraged by these results, a clickable 18F-labeled serine-based prosthetic group has been synthesized, again with the idea to improve the metabolic and pharmacokinetic profile of hydrophilic radiotracers. Therefore, an alkyne-carrying azido-functionalized serine derivative for coupling to biomolecules was synthesized and a chlorine leaving group for 18F-labeling, which could be accomplished using a microwave-assisted synthesis, a [K⊂2.2.2]+/carbonate system in DMSO. Radiochemical yields of 77±6% could be achieved.rnThe promising results obtained from the FR-targeting concept in the diagnostic field have been transferred to the boron neutron capture therapy. Therefore, a folate derivative was coupled to different boron clusters and cell uptake studies were conducted. The synthesis of the folate-boron clusters was straightforward. At first, a linker molecule based on maleic acid was synthesized, which was coupled to the boron cluster via Michael Addition of a thiol and alkene and subsequently coupled to the targeting moiety using CuAAC. The new conjugates of folate and boron clusters led to a significant increase of boron concentration in the cell of about 5-times compared to currently used and approved boron pharmaceuticals. rnMoreover, azido-folate derivatives were coupled to macromolecular carrier systems (pHPMA), which showed an enhanced and specific accumulation at target sites (up to 2.5-times) during in vivo experiments. A specific blockade could be observed up to 30% indicating an efficient targeting effect. A new kind of nanoparticles consisting of a PDLLA core and p((HPMA)-b-LMA)) as surfactants were developed and successfully radiolabeled via 18F-click chemistry in good RCYs of 8±3%rnThe nanoparticles were obtained via the miniemulsion technique in combination with solvent evaporation. The 18F-labeled nanoparticles were applied to in vivo testing using a mouse model. PET imaging showed a “mixed” biodistribution of low molecular weight as well as high molecular weight systems, indicating a partial loss of the 18F-labeled surfactant.rnIn conclusion, the presented work successfully utilized the FR-targeting concept in both, the diagnostic field (PET imaging) and for therapeutic approaches (BNCT, drug delivery systems). As a result, the high potential of FR-targeting in oncological applications has been shown and was confirmed by small animal PET imaging.rn