Small animal bone healing models : standards, tips, and pitfalls results of a consensus meeting


Autoria(s): Histing, T.; Garcia, P.; Holstein, J.; Klein, M.; Matthys, R.; Nuetzi, R.; Steck, R.; Laschke, M.W.; Wehner, T.; Bindl, R.; Recknagel, S.; Stuermer, E.; Vollmar, B.; Wildemann, B.; Lienau, J.; Willie, B.; Peters, A.; Ignatius, A.; Pohlemann, T.; Claes, L.; Menger, M.
Data(s)

19/07/2011

Resumo

Small animal fracture models have gained increasing interest in fracture healing studies. To achieve standardized and defined study conditions, various variables must be carefully controlled when designing fracture healing experiments in mice or rats. The strain, age and sex of the animals may influence the process of fracture healing. Furthermore, the choice of the fracture fixation technique depends on the questions addressed, whereby intra- and extramedullary implants as well as open and closed surgical approaches may be considered. During the last few years, a variety of different, highly sophisticated implants for fracture fixation in small animals have been developed. Rigid fixation with locking plates or external fixators results in predominantly intramembranous healing in both mice and rats. Locking plates, external fixators, intramedullary screws, the locking nail and the pin-clip device allow different degrees of stability resulting in various amounts of endochondral and intramembranous healing. The use of common pins that do not provide rotational and axial stability during fracture stabilization should be discouraged in the future. Analyses should include at least biomechanical and histological evaluations, even if the focus of the study is directed towards the elucidation of molecular mechanisms of fracture healing using the largely available spectrum of antibodies and gene-targeted animals to study molecular mechanisms of fracture healing. This review discusses distinct requirements for the experimental setups as well as the advantages and pitfalls of the different fixation techniques in rats and mice.

Identificador

http://eprints.qut.edu.au/46397/

Publicador

Elsevier

Relação

DOI:10.1016/j.bone.2011.07.007

Histing, T., Garcia, P., Holstein, J., Klein, M., Matthys, R., Nuetzi, R., Steck, R., Laschke, M.W., Wehner, T., Bindl, R., Recknagel, S., Stuermer, E., Vollmar, B., Wildemann, B., Lienau, J., Willie, B., Peters, A., Ignatius, A., Pohlemann, T., Claes, L., & Menger, M. (2011) Small animal bone healing models : standards, tips, and pitfalls results of a consensus meeting. Bone, 49(4), pp. 591-599.

Fonte

Institute of Health and Biomedical Innovation

Palavras-Chave #060800 ZOOLOGY #Animal bone healing models #Fracture healing #Rats #Mice #Fracture fixation
Tipo

Journal Article