937 resultados para peak retardation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new calibration method for a photoelastic modulator is proposed. The calibration includes a coarse calibration and a fine calibration. In the coarse calibration, the peak retardation of the photoelastic modulator is set near 1.841 rad. In the fine calibration, the value of the zeroth Bessel function is obtained. The zeroth Bessel function is approximated as a linear equation to directly calculate the peak retardation. In experiments, the usefulness of the calibration method is verified and the calibration error is less than 0.014 rad. The calibration is immune to the intensity fluctuation of the light source and independent of the circuit parameters. The method specially suits the calibration of a photoelastic modulator with a peak retardation of less than a half-wavelength. (c) 2007 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

针对现有光弹调制器标定方法的不足,提出了一种精确标定光弹调制器的新方法。首先利用起偏器、波片、光弹调制器和检偏器构成标定光路.通过寻找探测信号基频分量的极大值进行粗略标定,使光弹调制器的峰值延迟量处在1.841rad附近。然后撤走波片形成光弹凋制器的精确标定光路.在检偏器旋转90°前后获得探测信号的直流分量和二次谐波分量。最后利用这两种探测信号的直流分量和二次谐波分量精确地计算出光弹调制器的峰值延迟量。实验验让了此光掸调制器标定方法,实验结果表明其标定误差仅为0.7%。在此光掸凋制器标定方法中.光弹调制器

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lokale sekundäre Prozesse in glasbildenden Materialien sind wegen ihrer Wechselwirkung mit der primären Relaxation von besonderem Interesse. Für D-Sorbitol wurde die beta-Relaxation mit drei verschiedenen dielektrischen Meßtechniken untersucht und die Ergebnisse miteinander verglichen. Im Gegensatz zu konventionellen Messungen der dielektrischen Retardation, detektiert eine echte dielektrische Relaxationsmessung den Zerfall des elektrischen Feldes unter der Bedingung einer konstanten dielektrischen Verschiebung. Eine weitere dielektrische Relaxationsmethode ist die Solvatationsdynamik. Sie detektiert die dielektrische Relaxation in der direkten Umgebung eines Farbstoffmoleküls. Die Übereinstimmung der lokal ermittelten und der makroskopisch gemittelten Ergebnisse für den Glaszustand weisen darauf hin, daß die Sekundärrelaxation in D-Sorbitol eine räumlich homogene Eigenschaft ist. Im Gegensatz zu beta-Prozessen anderer Materialien, zeigt nur der abgeschreckte Glaszustand von ortho-Terphenyl einen sekundären Prozeß. Es wurde beobachtet, daß die beta-Amplitude beim Ausheilen langsam abnimmt und im Gleichgewichtszustand der Flüssigkeit oberhalb der Glasübergangstemperatur völlig verschwindet. Viele glasbildende Materialien, wie z. B. Salol zeigen keinen dielektrischen beta-Prozeß. Im Gegensatz zu Messungen mit Standardkühlraten, zeigt eine stark abgeschreckte Salol-Probe eine symmetrische dielektrische Sekundärrelaxation. Diese neuartige Eigenschaft von Salol verschwindet irreversibel, wenn sich die Temperatur der Glasübergangstemperatur nähert.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this chapter we propose clipping with amplitude and phase corrections to reduce the peak-to-average power ratio (PAR) of orthogonal frequency division multiplexed (OFDM) signals in high-speed wireless local area networks defined in IEEE 802.11a physical layer. The proposed techniques can be implemented with a small modification at the transmitter and the receiver remains standard compliant. PAR reduction as much as 4dB can be achieved by selecting a suitable clipping ratio and a correction factor depending on the constellation used. Out of band noise (OBN) is also reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel combinatory orthogonal frequency division multiplexing (PC-OFDM yields lower maximum peak-to-average power ratio (PAR), high bandwidth efficiency and lower bit error rate (BER) on Gaussian channels compared to OFDM systems. However, PC-OFDM does not improve the statistics of PAR significantly. In this chapter, the use of a set of fixed permutations to improve the statistics of the PAR of a PC-OFDM signal is presented. For this technique, interleavers are used to produce K-1 permuted sequences from the same information sequence. The sequence with the lowest PAR, among K sequences is chosen for the transmission. The PAR of a PC-OFDM signal can be further reduced by 3-4 dB by this technique. Mathematical expressions for the complementary cumulative density function (CCDF)of PAR of PC-OFDM signal and interleaved PC-OFDM signal are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of moving block signallings (MBS) has been adopted in a few mass transit railway systems. When a dense queue of trains begins to move from a complete stop, the trains can re-start in very close succession under MBS. The feeding substations nearby are likely to be overloaded and the service will inevitably be disturbed unless substations of higher power rating are used. By introducing starting time delays among the trains or limiting the trains’ acceleration rate to a certain extent, the peak energy demand can be contained. However, delay is introduced and quality of service is degraded. An expert system approach is presented to provide a supervisory tool for the operators. As the knowledge base is vital for the quality of decisions to be made, the study focuses on its formulation with a balance between delay and peak power demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel peak load management scheme for rural areas. The scheme transfers certain customers onto local nonembedded generators during peak load periods to alleviate network under voltage problems. This paper develops and presents this system by way of a case study in Central Queensland, Australia. A methodology is presented for determining the best location for the nonembedded generators as well as the number of generators required to alleviate network problems. A control algorithm to transfer and reconnect customers is developed to ensure that the network voltage profile remains within specification under all plausible load conditions. Finally, simulations are presented to show the performance of the system over a typical maximum daily load profile with large stochastic load variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop a Demand-Side-Response (DSR) model, which assists electricity end-users to be engaged in mitigating peak demands on the electricity network in Eastern and Southern Australia. The proposed innovative model will comprise a technical set-up of a programmable internet relay, a router, solid state switches in addition to the suitable software to control electricity demand at user's premises. The software on appropriate multimedia tool (CD Rom) will be curtailing/shifting electric loads to the most appropriate time of the day following the implemented economic model, which is designed to be maximizing financial benefits to electricity consumers. Additionally the model is targeting a national electrical load be spread-out evenly throughout the year in order to satisfy best economic performance for electricity generation, transmission and distribution. The model is applicable in region managed by the Australian Energy Management Operator (AEMO) covering states of Eastern-, Southern-Australia and Tasmania.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research suggests that students in their late teens and early twenties have not reached "identity formation" (James Marcia, 1969, 1980). The heightened anxiety and uncertainty about themselves and their future contribute to sometimes crippling fears emanating as anxiety, clinical depression and other mood disorders. This paper will explore some issues and suggest healthy ways of helping young people safely through these chaotic years and into a fulfilling career.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and effective down-sample algorithm, Peak-Hold-Down-Sample (PHDS) algorithm is developed in this paper to enable a rapid and efficient data transfer in remote condition monitoring applications. The algorithm is particularly useful for high frequency Condition Monitoring (CM) techniques, and for low speed machine applications since the combination of the high sampling frequency and low rotating speed will generally lead to large unwieldy data size. The effectiveness of the algorithm was evaluated and tested on four sets of data in the study. One set of the data was extracted from the condition monitoring signal of a practical industry application. Another set of data was acquired from a low speed machine test rig in the laboratory. The other two sets of data were computer simulated bearing defect signals having either a single or multiple bearing defects. The results disclose that the PHDS algorithm can substantially reduce the size of data while preserving the critical bearing defect information for all the data sets used in this work even when a large down-sample ratio was used (i.e., 500 times down-sampled). In contrast, the down-sample process using existing normal down-sample technique in signal processing eliminates the useful and critical information such as bearing defect frequencies in a signal when the same down-sample ratio was employed. Noise and artificial frequency components were also induced by the normal down-sample technique, thus limits its usefulness for machine condition monitoring applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reviews electricity consumption feedback literature to explore the potential of electricity feedback to affect residential consumers’ electricity usage patterns. The review highlights a substantial amount of literature covering the debate over the effectiveness of different feedback criteria to residential customer acceptance and overall conservation and peak demand reduction. Researchers studying the effects of feedback on everyday energy use have observed substantial variation in effect size, both within and between studies. Although researchers still continue to question the types of feedback that are most effective in encouraging conservation and peak load reduction, some trends have emerged. These include that feedback be received as quickly as possible to the time of consumption; be related to a standard; be clear and meaningful and where possible both direct and indirect feedback be customised to the customer. In general, the literature finds that feedback can reduce electricity consumption in homes by 5 to 20 per cent, but that significant gaps remain in our knowledge of the effectiveness and cost benefit of feedback.