4 resultados para optis
Resumo:
Pioneer work on iontophoresis undertaken by David Maurice during the 1970s and 1980s laid the initial groundwork for its potential implementation as a promising ocular therapeutic modality. A better understanding of tissue interactions within the eye during electric current application, along with better designs of drug delivery devices have enabled us to pursue David Maurice's original ideas and take them from the bench to the bed side. In the present study we demonstrate the potential application of an iontophoresis device (Eyegate, Optis, France) for the treatment of certain human eye diseases. Seventeen patients received a penetrating keratoplasty (PKP) at various intervals before presentation with active graft rejection in our clinic and were treated using this iontophoresis device. Methylprednisolone sodium succinate (MP) 62.5 mg/ml was infused within the Eyegate ocular probe container and an electrical current of 1.5 mA was delivered for 4 min with the negative pole connected to the ocular probe. Patients were treated on an ambulatory basis and received a standard course of three iontophoresis applications given once a day over 3 consecutive days. After treatment, 15 of the 17 treated eyes (88%) demonstrated a complete reversal of the rejection processes. In two eyes, only a partial and temporary improvement was observed. The mean best corrected visual acuity of all 17 patients during the last follow up visit was 0.37 +/- 0.2 compared to 0.06 +/- 0.05 before initiation of the iontophoresis treatment. The mean follow-up time was 13.7 months with a range of 5-29 months for the 17 patients. No significant side-effects associated with the iontophoresis treatment were observed. Thus, for the management of active corneal graft rejection, iontophoresis of MP can be an alternative to very frequent instillations of eye drops, or to pulsed intravenous therapy of corticosteroids.
Resumo:
Utilization of light and illumination systems in automotive industry for different purposes has been increased significantly in recent years. Volvo as one of the leading companies in manufacturing of luxury cars has found the great capacity in this area. The performance of such an illumination systems is one of the challenges that engineers in this industry are facing with. In this study an effort has been made to design a system to make the iron mark of Volvo being illuminated and the system is being evaluated by optics simulation in software using Ray optics method. At the end, results are assessed and some optimizations are carried out. Different kind of light guides, front side of the iron mark and some possible arrangement for LED also evaluated and different materials tested. The best combination from uniformity, color and amount of luminance aspect selected as a possible solution for this special project which can be used as a base for further studies in Volvo.
Resumo:
O objetivo do presente estudo consistiu em comparar as forças de deflexão in vitro entre fios estéticos e fio NiTi, para verificar a força máxima e da região platô e determinar sua correlação com o diâmetro do fio com e sem revestimento.
Foram realizados dez ensaios de sete marcas comerciais de arcos précontornados, sendo seis fios estéticos (Invu (I), Optis (O), Flexy Super Elastic Esthetic (FSEE), Niticosmetic (N), Orthocosmetic Elastinol (OE) e Pro Form
Coated Nitanium (PFCN)) e um fio NiTi superelástico (Nitinol Super Elastic (NSE)), aplicando-se o teste de curvatura de três pontos, associado a máquina de ensaios universal EMIC. Desenvolveu-se um dispositivo com braquetes cerâmicos (Transcend), cujos fios foram presos por elásticos modulares, sendo obtidos os valores da força de deflexão em 3,0, 2,0 e 1,0mm. O diâmetro dos fios com e sem revestimento foram mensurados com o especímetro digital Micromaster. A análise de variância a um critério (p<0,05) mostrou diferença
significante entre os fios e o teste post-hoc de Tukey determinou que a força de deflexão em 3mm para o O
Resumo:
O objetivo deste estudo foi avaliar a topografia de superfície dos fios estéticos, antes e após teste de deflexão. A amostra foi composta por 70 corpos de prova de fios 0,014 redondos, sendo 10 de cada uma das marcas comerciais avaliadas: Orthocosmetic Elastinol (Masel), Flexy Super Elastic Esthetic (Orthometric), InVu (TP Orthodontics) e ProForm Nitanium (Ortho Organizers) fios de NiTi revestidos por Teflon®; Optis (TP Orthodontics) fio de resina reforçado por fibra de vidro ou FRP; Niticosmetic (Tecnident) fio de NiTi revestido por resina epoxídica; e Nitinol SE (3M Unitek) fio de NiTi superelástico, usado para controle. A topografia de superfície de cada fio foi avaliada por rugosímetro e por microscópio óptico, antes e após ser submetido a ensaio de deflexão, no lado em que a força foi aplicada e no lado oposto a este. Cada fio foi defletido em 3,1mm, a uma velocidade de 1mm/min, com célula de carga de 5N a 36⁰C + 1⁰C. A análise de variância a três critérios (p<0,05) mostrou diferença significante entre os fios e o teste de Tukey mostrou que o fio Optis (TP Orthodontics) apresentou aumento nos parâmetros de rugosidade Ra, Rt e Rz, após a deflexão. O fio Niticosmetic (Tecnident) apresentou aumento na rugosidade média (Ra). O fio InVu (TP Orthodontics) foi o único que mostrou aumento na rugosidade no lado em que a força foi aplicada. A análise visual por meio de microscopia óptica revelou alterações na superfície em todos os fios estéticos após o teste de deflexão, desde delaminações do revestimento, observadas nos fios Orthocosmetic Elastinol e InVu, riscos permanentes na superfície, como visto nos fios Flexy Super Elastic Esthetic, Niticosmetic e ProForm Nitanium, e até mesmo fratura incompleta, no fio Optis. Concluiu-se que o fio Niticosmetic apresentou topografia de superfície similar ao fio metálico, e os demais fios estéticos apresentaram maior rugosidade e alterações visuaisna superfície.