Resumo

O objetivo do presente estudo consistiu em comparar as forças de deflexão in vitro entre fios estéticos e fio NiTi, para verificar a força máxima e da região platô e determinar sua correlação com o diâmetro do fio com e sem revestimento. Foram realizados dez ensaios de sete marcas comerciais de arcos précontornados, sendo seis fios estéticos (Invu (I), Optis (O), Flexy Super Elastic Esthetic (FSEE), Niticosmetic (N), Orthocosmetic Elastinol (OE) e Pro Form Coated Nitanium (PFCN)) e um fio NiTi superelástico (Nitinol Super Elastic (NSE)), aplicando-se o teste de curvatura de três pontos, associado a máquina de ensaios universal EMIC. Desenvolveu-se um dispositivo com braquetes cerâmicos (Transcend), cujos fios foram presos por elásticos modulares, sendo obtidos os valores da força de deflexão em 3,0, 2,0 e 1,0mm. O diâmetro dos fios com e sem revestimento foram mensurados com o especímetro digital Micromaster. A análise de variância a um critério (p<0,05) mostrou diferença significante entre os fios e o teste post-hoc de Tukey determinou que a força de deflexão em 3mm para o O<OE=PFCE<FSEE=NSE<I. O teste t-pareado comparou a força de deflexão (2-1mm) na região platô e mostrou que os fios O, FSEE e N apresentaram forças constantes. O fio da N apresentou o maior diâmetro entre as amostras, enquanto que os fios NSE e O, os menores. O Coeficiente de Correlação de Pearson mostrou que houve correlação entre o diâmetro do fio e a força de deflexão. Pode se concluir que há diferenças entre as forças produzidas pelos fios estéticos e que a força é diretamente proporcional ao seu diâmetro do fio com e sem revestimento para todas as deflexões, ou seja, quanto maior o diâmetro, maior a força produzida.

The aim of this study was to compare the forces of deflection in vitro between aesthetic and wire NiTi wires, to check the maximum force and plateau region and determine its correlation with the diameter of the wire with and without coating. Ten trials were conducted in seven brands of bows pre-skirted, six-wire aesthetic (InVu (I), Optis (O), Flexy Super Elastic Esthetic (FSEE), Orthocosmetic Elastinol (OE), Niticosmetic (N), and Pro Form Coated Nitanium (PFCN)) and a superelastic NiTi wire (Nitinol Super Elastic (NSE), applying The test is three-point bending, associated with universal machine EMIC. We developed a device with ceramic brackets (Transcend), whose strings were arrested for elastic modular, and obtained the values of the force deflection at 3.0, 2.0 and 1.0 mm. The diameter of the wires with and without coating were measured using digital especímetro Micromaster. The analysis of variance with a criterion (p <0.05) showed significant difference between the wires and post-hoc Tukey test determined that the force at 3mm deflection for wire O<OE=PFCE<FSEE=NSE<I. The paired t-test compared the strength of deflection (2-1mm) in the plateau region and showed that the wires O, FSEE and N showed constant forces. The wire N showed the largest diameter among the samples, while NSE wires and O, minors. The Pearson correlation coefficient showed that there was a correlation between the diameter of the wire and the force of deflection. It can be concluded that there are differences between the forces produced by the wires and aesthetic that force is directly proportional to the diameter of the uncoated wire for all peaks, ie the larger the diameter, the greater the force produced.

Formato

application/pdf

Identificador

SANTORO, Miller Zaroni. Comparison between the forces deflection wires behavior of and its coating influence.. 2011. 89 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2011.

http://tede.metodista.br/jspui/handle/tede/1287

Idioma(s)

por

Publicador

Universidade Metodista de São Paulo

Ortodontia

BR

UMESP

PÓS GRADUAÇÃO EM ORTODONTIA

Direitos

Acesso Aberto

Palavras-Chave #Fios Ortodônticos #Resina epóxi #Teflon. #Orthodontic wire #epoxy resin #Teflon. #CNPQ::CIENCIAS DA SAUDE
Tipo

Dissertação