996 resultados para ocular imaging instruments
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
Introducción: El glaucoma representa la tercera causa de ceguera a nivel mundial y un diagnóstico oportuno requiere evaluar la excavación del nervio óptico que está relacionada con el área del mismo. Existen reportes de áreas grandes (macrodiscos) que pueden ser protectoras, mientras otros las asocian a susceptibilidad para glaucoma. Objetivo: Establecer si existe asociación entre macrodisco y glaucoma en individuos estudiados con Tomografía Optica Coherente (OCT ) en la Fundación Oftalmológica Nacional. Métodos: Estudio transversal de asociación que incluyó 25 ojos con glaucoma primario de ángulo abierto y 74 ojos sanos. A cada individuo se realizó examen oftalmológico, campo visual computarizado y OCT de nervio óptico. Se compararon por grupos áreas de disco óptico y número de macrodiscos, definidos según Jonas como un área de la media más dos desviaciones estándar y según Adabache como área ≥3.03 mm2 quien evaluó población Mexicana. Resultados: El área promedio de disco óptico fue 2,78 y 2,80 mm2 glaucoma Vs. sanos. De acuerdo al criterio de Jonas, se observó un macrodisco en el grupo sanos y según criterio de Adabache se encontraron ocho y veinticinco macrodiscos glaucoma Vs. sanos. (OR=0,92 IC95%=0.35 – 2.43). Discusión: No hubo diferencia significativa (P=0.870) en el área de disco entre los dos grupos y el porcentaje de macrodiscos para los dos grupos fue similar, aunque el bajo número de éstos no permitió concluir en términos estadísticos sobre la presencia de macrodisco y glaucoma.
Resumo:
Improvements in imaging chips and computer processing power have brought major advances in imaging of the anterior eye. Digitally captured images can be visualised immediately and can be stored and retrieved easily. Anterior ocular imaging techniques using slitlamp biomicroscopy, corneal topography, confocal microscopy, optical coherence tomography (OCT), ultrasonic biomicroscopy, computerised tomography (CT) and magnetic resonance imaging (MRI) are reviewed. Conventional photographic imaging can be used to quantify corneal topography, corneal thickness and transparency, anterior chamber depth and lateral angle and crystalline lens position, curvature, thickness and transparency. Additionally, the effects of tumours, foreign bodies and trauma can be localised, the corneal layers can be examined and the tear film thickness assessed. © 2006 The Authors.
Resumo:
Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.
Resumo:
The suite of SECCHI optical imaging instruments on the STEREO-A spacecraft is used to track a solar storm, consisting of several coronal mass ejections (CMEs) and other coronal loops, as it propagates from the Sun into the heliosphere during May 2007. The 3-D propagation path of the largest interplanetary CME (ICME) is determined from the observations made by the SECCHI Heliospheric Imager (HI) on STEREO-A (HI-1/2A). Two parts of the CME are tracked through the SECCHI images, a bright loop and a V-shaped feature located at the rear of the event. We show that these two structures could be the result of line-of-sight integration of the light scattered by electrons located on a single flux rope. In addition to being imaged by HI, the CME is observed simultaneously by the plasma and magnetic field experiments on the Venus Express and MESSENGER spacecraft. The imaged loop and V-shaped structure bound, as expected, the flux rope observed in situ. The SECCHI images reveal that the leading loop-like structure propagated faster than the V-shaped structure, and a decrease in in situ CME speed occurred during the passage of the flux rope.We interpret this as the result of the continuous radial expansion of the flux rope as it progressed outward through the interplanetary medium. An expansion speed in the radial direction of ~30 km s-1 is obtained directly from the SECCHI-HI images and is in agreement with the difference in speed of the two structures observed in situ. This paper shows that the flux rope location can be determined from white light images, which could have important space weather applications.
Resumo:
A primary purpose of this research is to design a gradient coil that is planar in construction and can be inserted within existing infrastructure. The proposed wave equation method for the design of gradient coils is novel within the field. it is comprehensively shown how this method can be used to design the planar x-, y-, and z-gradient wire windings to produce the required magnetic fields within a certain domain. The solution for the cylindrical gradient coil set is also elucidated. The wave equation technique is compared with the well-known target held method to gauge the quality of resultant design. In the case of the planar gradient coil design, it is shown that using the new method, a set of compact gradient coils with large field of view can be produced. The final design is considerably smaller in dimension when compared with the design obtained using the target field method, and therefore the manufacturing costs and materials required are somewhat reduced.
Resumo:
Aim: Identify the incidence of vitreomacular traction (VMT) and frequency of reduced vision in the absence of other coexisting macular pathology using a pragmatic classification system for VMT in a population of patients referred to the hospital eye service. Methods: A detailed survey of consecutive optical coherence tomography (OCT) scans was done in a high-throughput ocular imaging service to ascertain cases of vitreomacular adhesion (VMA) and VMT using a departmental classification system. Analysis was done on the stages of traction, visual acuity, and association with other macular conditions. Results: In total, 4384 OCT scan episodes of 2223 patients were performed. Two hundred and fourteen eyes had VMA/VMT, with 112 eyes having coexisting macular pathology. Of 102 patients without coexisting pathology, 57 patients had VMT grade between 2 and 8, with a negative correlation between VMT grade and number of Snellen lines (r= -0.61717). There was a distinct cutoff in visual function when VMT grade was higher than 4 with the presence of cysts and sub retinal separation and breaks in the retinal layers. Conclusions: VMT is a common encounter often associated with other coexisting macular pathology. We estimated an incidence rate of 0.01% of VMT cases with reduced vision and without coexisting macular pathology that may potentially benefit from intervention. Grading of VMT to select eyes with cyst formation as well as hole formation may be useful for targeting patients who are at higher risk of visual loss from VMT.
Resumo:
We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.
Resumo:
PURPOSE Fundus autofluorescence (AF) is characterized not only by its intensity or excitation and emission spectra but also by the lifetimes of the fluorophores. Fluorescence lifetime is influenced by the fluorophore's microenvironment and may provide information about the metabolic tissue state. We report quantitative and qualitative autofluorescence lifetime imaging of the ocular fundus in mice. METHODS A fluorescence lifetime imaging ophthalmoscope (FLIO) was used to measure fluorescence lifetimes of endogenous fluorophores in the murine retina. FLIO imaging was performed in 1-month-old C57BL/6, BALB/c, and C3A.Cg-Pde6b(+)Prph2(Rd2)/J mice. Measurements were repeated at monthly intervals over the course of 6 months. For correlation with structural changes, an optical coherence tomogram was acquired. RESULTS Fundus autofluorescence lifetime images were readily obtained in all mice. In the short spectral channel (498-560 nm), mean ± SEM AF lifetimes were 956 ± 15 picoseconds (ps) in C57BL/6; 801 ± 35 ps in BALB/c mice; and 882 ± 37 ps in C3A.Cg-Pde6b(+)Prph2(Rd2)/J mice. In the long spectral channel (560-720 nm), mean ± SEM AF lifetimes were 298 ± 14 ps in C57BL/6 mice, 241 ± 10 ps in BALB/c mice, and 288 ± 8 ps in C3A.Cg-Pde6b(+)Prph2(Rd2)/J mice. There was a general decrease in mean AF lifetimes with age. CONCLUSIONS Although fluorescence lifetime values differ among mouse strains, we found little variance within the groups. Fundus autofluorescence lifetime imaging in mice may provide additional information for understanding retinal disease processes and may facilitate monitoring of therapeutic effects in preclinical studies.
Resumo:
Mechanical thrombectomy provides higher recanalization rates than intravenous or intra-arterial thrombolysis. Finally this has been shown to translate into improved clinical outcome in six multicentric randomized controlled trials. However, within cohorts the clinical outcomes may vary, depending on the endovascular techniques applied. Systems aiming mainly for thrombus fragmentation and lacking a protection against distal embolization have shown disappointing results when compared to recent stent-retriever studies or even to historical data on local arterial fibrinolysis. Procedure-related embolic events are usually graded as adverse events in interventional neuroradiology. In stroke, however, the clinical consequences of secondary emboli have so far mostly been neglected and attributed to progression of the stroke itself. We summarize the evolution of instruments and techniques for endovascular, image-guided, microneurosurgical recanalization in acute stroke, and discuss how to avoid procedure-related embolic complications.
Resumo:
Purpose To evaluate the imaging characteristics of a cohort of patients with ocular adnexal lymphoproliferative disease (OALD). Methods A noncomparative retrospective review between 1992 and 1995 and prospective study from 1995 to 2005 of the clinical, imaging and treatment of 105 patients presenting to tertiary orbital referral centre presenting with OALD. Results One hundred and five patients (mean age 61 years, range 11-90 years) with equal gender distribution were included. Fifty-three were primary and 52 were secondary. Computed tomography (CT) usually showed a well-circumscribed lesion of greater than brain density, moulding to adjacent tissues with moderate enhancement. Aggressive histology was associated with bone destruction, while moulding was associated with indolent histology (P < 0.005). MRI in OALD showed intermediate signal intensity on T1- and T2-weighted images and moderate enhancement with gadolinium. Gallium scanning sensitivity to detect ocular adnexal disease was 25 and 57% for systemic involvement. Positron emission tomography (PET) upstaged (71%) of patients with systemic lymphoproliferative involvement, having a higher sensitivity than CT in detecting distant disease (86 vs 72%). Conclusions CT and/ or MRI are essential in the evaluation of OALD and can be used to establish that an orbital lesion may be lymphoprolifetaive in nature. Further, these imaging modalities may predict the behaviour of the lymphoma in certain cases. Gallium scanning provides no additional information to CT and does not influence patient treatment. PET represents an important addition to the assessment of OALD with real impact on patient management.
Resumo:
Conventional reflectance spectroscopy (NIRS) and hyperspectral imaging (HI) in the near-infrared region (1000-2500 nm) are evaluated and compared, using, as the case study, the determination of relevant properties related to the quality of natural rubber. Mooney viscosity (MV) and plasticity indices (PI) (PI0 - original plasticity, PI30 - plasticity after accelerated aging, and PRI - the plasticity retention index after accelerated aging) of rubber were determined using multivariate regression models. Two hundred and eighty six samples of rubber were measured using conventional and hyperspectral near-infrared imaging reflectance instruments in the range of 1000-2500 nm. The sample set was split into regression (n = 191) and external validation (n = 95) sub-sets. Three instruments were employed for data acquisition: a line scanning hyperspectral camera and two conventional FT-NIR spectrometers. Sample heterogeneity was evaluated using hyperspectral images obtained with a resolution of 150 × 150 μm and principal component analysis. The probed sample area (5 cm(2); 24,000 pixels) to achieve representativeness was found to be equivalent to the average of 6 spectra for a 1 cm diameter probing circular window of one FT-NIR instrument. The other spectrophotometer can probe the whole sample in only one measurement. The results show that the rubber properties can be determined with very similar accuracy and precision by Partial Least Square (PLS) regression models regardless of whether HI-NIR or conventional FT-NIR produce the spectral datasets. The best Root Mean Square Errors of Prediction (RMSEPs) of external validation for MV, PI0, PI30, and PRI were 4.3, 1.8, 3.4, and 5.3%, respectively. Though the quantitative results provided by the three instruments can be considered equivalent, the hyperspectral imaging instrument presents a number of advantages, being about 6 times faster than conventional bulk spectrometers, producing robust spectral data by ensuring sample representativeness, and minimizing the effect of the presence of contaminants.
Resumo:
A 33-year-old woman complained of unilateral eyelid edema and blurred vision. Initial ophthalmic examination disclosed anterior chamber reaction with keratic precipitates on the cornea, without posterior abnormalities. Anterior uveitis was treated. Despite that, patient showed rapidly progressive unilateral vision loss with optic nerve swelling. Systemic workup was inconclusive, as well as cranial magnetic resonance imaging and cerebrospinal fluid examination. Based on the hypothesis of optic neuritis, intravenous methylprednisolone pulse was performed with no success. During the following days, the patient presented pericardial effusion and cardiac tamponade, progressing to death. Necropsy was performed and diagnosis of extranodal natural killers/T-cell lymphoma, nasal type with ocular involvement was confirmed by immunohistochemistry.
Resumo:
Magnetic resonance imaging (MRI) was used to evaluate and compare with anthropometry a fundamental bioelectrical impedance analysis (BIA) method for predicting muscle and adipose tissue composition in the lower limb. Healthy volunteers (eight men and eight women), aged 41 to 62 years, with mean (S.D.) body mass indices of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m(2) respectively, were subjected to MRI leg scans, from which 20-cm sections of thigh and IO-cm sections of lower leg (calf) were analysed for muscle and adipose tissue content, using specifically developed software. Muscle and adipose tissue were also predicted from anthropometric measurements of circumferences and skinfold thicknesses, and by use of fundamental BIA equations involving section impedance at 50 kHz and tissue-specific resistivities. Anthropometric assessments of circumferences, cross-sectional areas and volumes for total constituent tissues matched closely MRI estimates. Muscle volume was substantially overestimated (bias: thigh, -40%; calf, -18%) and adipose tissue underestimated (bias: thigh, 43%; calf, 8%) by anthropometry, in contrast to generally better predictions by the fundamental BIA approach for muscle (bias:thigh, -12%; calf, 5%) and adipose tissue (bias:thigh, 17%; calf, -28%). However, both methods demonstrated considerable individual variability (95% limits of agreement 20-77%). In general, there was similar reproducibility for anthropometric and fundamental BIA methods in the thigh (inter-observer residual coefficient of variation for muscle 3.5% versus 3.8%), but the latter was better in the calf (inter-observer residual coefficient of variation for muscle 8.2% versus 4.5%). This study suggests that the fundamental BIA method has advantages over anthropometry for measuring lower limb tissue composition in healthy individuals.
Resumo:
Imaging of the head and neck is the most commonly performed clinical magnetic resonance imaging (MRI) examination [R. G. Evans and J. R. G. Evans, AJR 157, 603 (1991)]. This is usually undertaken in a generalist MRI instrument containing superconducting magnet system capable of imaging all organs. These generalist instruments are large, typically having a bore of 0.9-1.0 m and a length of 1.7-2.5 m and therefore are expensive to site, somewhat claustrophobic to the patient, and offer little access by attending physicians. In this article, we present the design of a compact, superconducting MRI magnet for head and neck imaging that is less than 0.8 m in length and discuss in detail the design of an asymmetric gradient coil set, tailored to the magnet profile. In particular, the introduction of a radio-frequency FM modulation scheme in concert with a gradient sequence allows the epoch of the linear region of the gradient set to be much closer to the end of the gradient structure than was previously possible. Images from a prototype gradient set demonstrate the effectiveness of the designs. (C) 1999 American Institute of Physics. [S0034-6748(99)04910-2].