965 resultados para objective measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A challenge for the clinical management of advanced Parkinson’s disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, we investigate a new objective measurement for assessing the video playback quality for services delivered in networks that use TCP as a transport layer protocol. We define the new metric as pause intensity to characterize the quality of playback in terms of its continuity since, in the case of TCP, data packets are protected from losses but not from delays. Using packet traces generated from real TCP connections in a lossy environment, we are able to simulate the playback of a video and monitor buffer behaviors in order to calculate pause intensity values. We also run subjective tests to verify the effectiveness of the metric introduced and show that the results of pause intensity and the subjective scores made over the same real video clips are closely correlated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Seventy four asthmatic children aged 7 to 11 years were examined along with controls matched by age and sex. Clinical and laboratory investigations preceded a 28-day follow-up where data about morning and evening peak expiratory flow rate (PEF), symptoms and treatment were recorded. The coefficient of variation of PEF was found to be an objective measurement of asthma severity that has statistically significant correlation with both symptoms (r s= .36) and treatment (r s= .60). Moreover, it separates mild and severe asthmatics, as confirmed by statistically significant differences (p= .008 or less) in symptoms, treatment, skin allergy and airways response to exercise. Skin allergy and airways responsiveness to exercise were found to be predictors of both disease and severity. By means of logistic regression analysis it was possible to establish the probabilities for both asthma and severe asthma when children presenting and not presenting these characteristics are compared. One single positive skin test represent a probability of 88% for the development of asthma and a probability of 70% for severe disease. A PEF reduction of 10% after an exercise test implies a probability of 73% for disease and a probability of 64% for severe disease. Increases in these variables imply geometrically increased risks and their presence together have a multiplicative effect in the final risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: An objective measurement of surgical procedures outcomes is inherent to professional practices quality control; this especially applies in orthopaedics to joint replacement outcomes. A self-administered questionnaire offers an attractive alternative to surgeon's judgement but is infrequently used in France for these purposes. The British questionnaire, the 12-item Oxford Hip Score (OHS) was selected for this study because of its ease of use. HYPOTHESIS: The objective of this study was to validate the French translation of the self-assessment 12-item Oxford Hip Score and compare its results with those of the reference functional scores: the Harris Hip Score (HHS) and the Postel-Merle d'Aubigné (PMA) score. MATERIALS AND METHODS: Based on a clinical series of 242 patients who were candidates for total hip arthroplasty, the French translation of this questionnaire was validated. Its coherence was also validated by comparing the preoperative data with the data obtained from the two other reference clinical scores. RESULTS: The translation was validated using the forward-backward translation procedure from French to English, with correction of all differences or mistranslations after systematized comparison with the original questionnaire in English. The mean overall OHS score was 43.8 points (range, 22-60 points) with similarly good distribution of the overall value of the three scores compared. The correlation was excellent between the OHS and the HHS, but an identical correlation between the OHS and the PMA was only obtained for the association of the pain and function parameters, after excluding the mobility criterion, relatively over-represented in the PMA score. DISCUSSION AND CONCLUSION: Subjective questionnaires that contribute a personal appreciation of the results of arthroplasty by the patient can easily be applied on a large scale. This study made a translated and validated version of an internationally recognized, reliable self-assessment score available to French orthopaedic surgeons. The results obtained encourage us to use this questionnaire as a complement to the classical evaluation scores and methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: Psychomotor retardation is part of Major Depression (MD) diagnosis criteria and has been assimilated to bradykinesia, even though there is a clear lack of objective measurement of motor activity in MD. We conducted a study to evaluate bradykinesia, posture and gait parameters in MD patients with an ambulatory system, allowing continuous motor measurements. Methods: Patients with DSM-IV MD and healthy controls matched for age and sex were asked to carry on with their usual activities while being recorded for 6 hours by a wireless autonomous ambulatory system, containing miniature gyroscopes, data-logger, battery and flash memory. allowing continuous recording of upper limbs movements (speed, amplitude and activity (% of time with movement)), posture (% of time standing, walking, lying or sitting) and gait parameters (speed, cadence, stance, double support, stride). Results: Hands activity was significantly lower in depressed patients, as compared to controls (MD: 40%, controls: 60%; p<0.05). Speed of hand movements (p= 0.13) and their amplitude (p=0.71) were similar to controls. MD patients had a trend to spend more time lying or sitting than controls (p=0.06) but did not differ in terms of any gait parameters. Conclusion: Patients with MD displayed less hand movements than controls and tended to spend more time lying or sitting over 6 hours, but did not differ in terms of speed and amplitude of movement, nor in gait parameters. These results suggest that psychomotor retardation classically described in MD might be the expression of a paucity of movement rather than a bradykinesia as observed in parkinsonism and might involved different (nondopaminergic) mechanisms.