80 resultados para keratoconus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Keratoconus, a common inherited ocular disorder resulting in progressive corneal thinning, is the leading indication for corneal transplantation in the developed world. Genome-wide association studies have identified common SNPs 100 kb upstream of ZNF469 strongly associated with corneal thickness. Homozygous mutations in ZNF469 and PR domain-containing protein 5 (PRDM5) genes result in brittle cornea syndrome (BCS) Types 1 and 2, respectively. BCS is an autosomal recessive generalized connective tissue disorder associated with extreme corneal thinning and a high risk of corneal rupture. Some individuals with heterozygous PRDM5 mutations demonstrate a carrier ocular phenotype, which includes a mildly reduced corneal thickness, keratoconus and blue sclera. We hypothesized that heterozygous variants in PRDM5 and ZNF469 predispose to the development of isolated keratoconus. We found a significant enrichment of potentially pathologic heterozygous alleles in ZNF469 associated with the development of keratoconus (P = 0.00102) resulting in a relative risk of 12.0. This enrichment of rare potentially pathogenic alleles in ZNF469 in 12.5% of keratoconus patients represents a significant mutational load and highlights ZNF469 as the most significant genetic factor responsible for keratoconus identified to date.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To present 7 cases of peripheral sterile corneal infiltrates that occurred after corneal cross-linking (CXL) for progressive keratectasia. Methods: Seven patients who had their progressive keratoconus documented underwent corneal deepithelization and subsequently CXL, which was performed with the application of 0.1% riboflavin with 20% dextran, and exposure to UVA light (370 nm, 2.9-3.1 mW/cm(2)) for 30 minutes. Results: Nearly a week after the procedure, the patients presented with peripheral stromal infiltrates. The ring-like infiltrates were superficial and were present at the 9.0-mm zone. Sterile infiltration was diagnosed. Patients were treated with topical corticosteroids, and complete resolution was achieved after a few weeks of treatment. Conclusions: We hypothesize that the phototoxic effect on the corneal stroma may be the main mechanism that triggers these infiltrates. Alternatively, alterations in antigenicity that occur in native proteins after CXL could result in patients recognizing the proteins as nonself and mounting immune responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To report refractive, topographic, aberrometric, and tomographic outcomes 24 months after corneal cross-linking (CXL) in patients up to 18 years of age with progressive keratoconus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the performance of dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in measuring intraocular pressure in eyes with irregular corneas. METHODS: GAT and DCT measures were taken in 30 keratoconus and 29 postkeratoplasty eyes of 35 patients after pachymetry and corneal topography. Regression and correlation analyses were performed between both tonometry methods and between tonometry methods and corneal parameters. Bland-Altman plots were constructed. RESULTS: DCT values were significantly higher than GAT values in both study groups: +4.1 +/- 2.3 mm Hg (mean +/- SD) in keratoconus and +3.1 +/- 2.5 mm Hg after keratoplasty. In contrast to DCT, GAT values were significantly higher in postkeratoplasty eyes than in keratoconus. The correlation between the 2 tonometry methods was moderate in keratoconus (Kendall correlation coefficient, tau = 0.34) as well in postkeratoplasty eyes (tau = 0.66). The +/-1.96 SD span of the DCT-GAT differences showed a considerable range: -0.42 to +8.70 mm Hg in keratoconus and -1.87 to +7.98 mm Hg in postkeratoplasty eyes. In the keratoconus group, neither DCT nor GAT correlated significantly with any of the corneal parameters. In the postkeratoplasty group, both DCT and GAT measures showed a moderate positive correlation with corneal steepness, but only DCT had a significant negative correlation with the central corneal thickness (tau = -0.33). CONCLUSIONS: DCT measured significantly higher intraocular pressures than GAT in keratoconus and postkeratoplasty eyes. DCT and GAT measures varied considerably, and DCT was not less dependent on biomechanical properties of irregular corneas than GAT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To extend the capabilities of the Cone Location and Magnitude Index algorithm to include a combination of topographic information from the anterior and posterior corneal surfaces and corneal thickness measurements to further improve our ability to correctly identify keratoconus using this new index: ConeLocationMagnitudeIndex_X. DESIGN Retrospective case-control study. METHODS Three independent data sets were analyzed: 1 development and 2 validation. The AnteriorCornealPower index was calculated to stratify the keratoconus data from mild to severe. The ConeLocationMagnitudeIndex algorithm was applied to all tomography data collected using a dual Scheimpflug-Placido-based tomographer. The ConeLocationMagnitudeIndex_X formula, resulting from analysis of the Development set, was used to determine the logistic regression model that best separates keratoconus from normal and was applied to all data sets to calculate PercentProbabilityKeratoconus_X. The sensitivity/specificity of PercentProbabilityKeratoconus_X was compared with the original PercentProbabilityKeratoconus, which only uses anterior axial data. RESULTS The AnteriorCornealPower severity distribution for the combined data sets are 136 mild, 12 moderate, and 7 severe. The logistic regression model generated for ConeLocationMagnitudeIndex_X produces complete separation for the Development set. Validation Set 1 has 1 false-negative and Validation Set 2 has 1 false-positive. The overall sensitivity/specificity results for the logistic model produced using the ConeLocationMagnitudeIndex_X algorithm are 99.4% and 99.6%, respectively. The overall sensitivity/specificity results for using the original ConeLocationMagnitudeIndex algorithm are 89.2% and 98.8%, respectively. CONCLUSIONS ConeLocationMagnitudeIndex_X provides a robust index that can detect the presence or absence of a keratoconic pattern in corneal tomography maps with improved sensitivity/specificity from the original anterior surface-only ConeLocationMagnitudeIndex algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To compare the occurrence rate and depth of the demarcation line and topographical outcome after corneal cross-linking (CXL) for keratoconus using two different treatment protocols. METHODS A retrospective analysis of 131 eyes with progressive keratoconus treated with CXL using riboflavin and UV-A was performed. Eyes were treated either with the standard Dresden protocol (30 minutes irradiation, 3 mW/cm(2), UV-XTM 1000) or a rapid protocol (10 minutes irradiation, 9 mW/cm(2), UV-XTM 2000). The presence and depth of the corneal demarcation line was assessed with an anterior segment optical coherence tomography device 1 month after CXL by a masked observer. Corneal topography and tomography was performed at baseline and at 12-month follow-up with Pentacam and the TMS (Topographic Modeling System) device. RESULTS In the standard protocol group, 76.5% (62/81) of treated corneas revealed a demarcation line 1 month after CXL, whereas such a demarcation line was observed in only 22% (11/50) of eyes treated with the rapid protocol (P < 0.0001). The demarcation line was significantly more superficial in the rapid protocol group (P = 0.004). Corneal topography values between baseline and 12 months after CXL showed a mean change of -0.76 diopters (D) in Kmax (SD ± 2.7) in the standard protocol group versus a mean change of +0.72 D in Kmax (SD ± 1.5) in the rapid protocol (P = 0.007). CONCLUSIONS The rapid CXL protocol negatively influences the occurrence and depth of the demarcation line 1 month after CXL. Our results show a negative effect on the topographical outcome 1 year after CXL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To describe the clinical outcome of corneal cross-linking (CXL) in a young child with keratoconus. METHODS This is a case report of a young girl with keratoconus with ophthalmologic findings and 3-year follow-up. Follow-up visits included visual acuity measurement, retinoscopy, corneal tomography, and topography. RESULTS A girl with Down syndrome was diagnosed with bilateral keratoconus and relative amblyopia at the age of 4 years. The best-corrected near visual acuity was 20/100 binocularly. Corneal tomography showed the following parameters: OD K(max) 47.2 diopters (D), thinnest location 442 μm; OS K(max) 49.6 D, thinnest location 432 μm. Three months later, the keratoconus in the left eye progressed (K(max) 50.2 D, thinnest location 424 μm), and CXL was performed. One year later, CXL was necessary also in the right eye because of progression. The girl was most recently reexamined at the age of 7 years. The corrected near visual acuity was 20/80 in both eyes. The corneal curvature slightly flattened, and the corneal thickness stabilized (OD K(max) 46.8 D, thinnest location 389 μm; OS K(max) 49.4 D, thinnest location 360 μm). CONCLUSIONS Onset of keratoconus can occur in early childhood, especially in patients with Down syndrome. In this case, CXL was performed at 4 and 5 years of age without complications and stopped further keratoconus progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To determine whether the scleral stroma is affected as much as the corneal stroma in keratoconus. SETTING University Eye Clinic, Bern, Switzerland. DESIGN Comparative case-control study. METHODS Eyes with keratoconus (keratoconus group) and eyes of age-, sex-, and axial length-matched controls (control group) were analyzed. Corneal videokeratometry and pachymetry were performed using a Scheimpflug tomographer (Pentacam). For measurements of the peripheral cornea and the anterior sclera, a spectral-domain anterior segment optical coherence tomography device (Spectralis) was used. RESULTS The study group comprised 51 eyes and the control group, 50 eyes. The mean central corneal thickness in the keratoconus group was statistically significantly lower than in the control group (447.8 μm ± 57.8 [SD] versus 550.5 ± 35.5 μm) (P < .0001). No significant difference in the mean anterior scleral thickness was found between the keratoconus group and the control group (479.1 ± 43.7 μm versus 474.2 ± 43.0 μm) (P =.57). CONCLUSION Although corneal thinning was observed in keratoconus patients, the anterior scleral stroma thickness in these patients seemed to be similar to that in healthy control eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To analyze and compare the relationship between anterior and posterior corneal shape evaluated by a tomographic system combining the Scheimpflug photography and Placido-disc in keratoconus and normal healthy eyes, as well as to evaluate its potential diagnostic value. Methods Comparative case series including a sample of 161 eyes of 161 subjects with ages ranging from 7 to 66 years and divided into two groups: normal group including 100 healthy eyes of 100 subjects, and keratoconus group including 61 keratoconus eyes of 61 patients. All eyes received a comprehensive ophthalmologic examination including an anterior segment analysis with the Sirius system (CSO). Antero-posterior ratios for corneal curvature (k ratio) and shape factor (p ratio) were calculated. Logistic regression analysis was used to evaluate if some antero–posterior ratios combined with other clinical parameters were predictors of the presence of keratoconus. Results No statistically significant differences between groups were found in the antero–posterior k ratios for 3-, 5- and 7-mm diameter corneal areas (p ≥ 0.09). The antero–posterior p ratio for 4.5- and 8-mm diameter corneal areas was significantly higher in the normal group than in the keratoconus group (p < 0.01). The k ratio for 3, 5, and 7 mm was significantly higher in the keratoconus grade IV subgroup than in the normal group (p < 0.01). Furthermore, significant differences were found in the p ratio between the normal group and the keratoconus grade II subgroup (p ≤ 0.01). Finally, the logistic regression analysis identified as significant independent predictors of the presence of keratoconus (p < 0.01) the 8-mm anterior shape factor, the anterior chamber depth, and the minimal corneal thickness. Conclusions The antero-posterior k and p ratios are parameters with poor prediction ability for keratoconus, in spite of the trend to the presence of more prolate posterior corneal surfaces compared to the anterior in keratoconus eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To assess in a sample of normal, keratoconic, and keratoconus (KC) suspect eyes the performance of a set of new topographic indices computed directly from the digitized images of the Placido rings. Methods. This comparative study was composed of a total of 124 eyes of 106 patients from the ophthalmic clinics Vissum Alicante and Vissum Almería (Spain) divided into three groups: control group (50 eyes), KC group (50 eyes), and KC suspect group (24 eyes). In all cases, a comprehensive examination was performed, including the corneal topography with a Placidobased CSO topography system. Clinical outcomes were compared among groups, along with the discriminating performance of the proposed irregularity indices. Results. Significant differences at level 0.05 were found on the values of the indices among groups by means of Mann-Whitney-Wilcoxon nonparametric test and Fisher exact test. Additional statistical methods, such as receiver operating characteristic analysis and K-fold cross validation, confirmed the capability of the indices to discriminate between the three groups. Conclusions. Direct analysis of the digitized images of the Placido mires projected on the cornea is a valid and effective tool for detection of corneal irregularities. Although based only on the data from the anterior surface of the cornea, the new indices performed well even when applied to the KC suspect eyes. They have the advantage of simplicity of calculation combined with high sensitivity in corneal irregularity detection and thus can be used as supplementary criteria for diagnosing and grading KC that can be added to the current keratometric classifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the correlation of the mean curvature and shape factors of both corneal surfaces for different corneal diameters measured with the Scheimpflug photography–based system in keratoconus eyes. Methods: A total of 61 keratoconus eyes of 61 subjects, aged 14 to 64 years, were included in this study. All eyes received a comprehensive ophthalmologic examination including anterior segment and corneal analysis with the Sirius system (CSO): anterior and posterior mean corneal radius for 3, 5, and 7 mm (aKM, pKM), anterior and posterior mean shape factor for 4.5 and 8 mm (ap, pp), central and minimal corneal thickness, and anterior chamber depth. Results: Mean aKM/pKM ratio around 1.20 (range, 0.95–1.48) was found for all corneal diameters (P = 0.24). Weak but significant correlations of this ratio with pachymetric parameters were found (r between −0.28 and −0.34, P < 0.04). The correlation coefficient between aKM and pKM was ≥0.92 for all corneal diameters. A strong and significant correlation was also found between ap and pp (r ≥ 0.86, P < 0.01). The multiple regression analysis revealed that central pKM was significantly correlated with aKM, central corneal thickness, anterior chamber depth, and spherical equivalent (R2 ≥ 0.88, P < 0.01) and that 8 mm pp was significantly correlated with 8 mm ap and age (R2 = 0.89, P < 0.01). Conclusions: Central posterior corneal curvature and shape factor in the keratoconus eye can be consistently predicted from the anterior corneal curvature and shape factor, respectively, in combination with other anatomical and ocular parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. Methods: The nkexact value was determined by obtaining differences (DPc) between keratometric corneal power (Pk) and Gaussian corneal power (PGauss c ) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of DPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with PGauss c , Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. Results: nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and PGauss c did not exceed 60.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadj and True Net Power and Pk(1.3375) and Pkadj were statistically different (P , 0.01), whereas no differences were found between PGauss c and Pkadj (P . 0.01). Conclusions: The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.