Evaluation of scleral and corneal thickness in keratoconus patients


Autoria(s): Schlatter, Bettina; Beck, Marco; Früh Epstein, Beatrice; Tappeiner, Christoph; Zinkernagel, Martin
Data(s)

01/05/2015

Resumo

PURPOSE To determine whether the scleral stroma is affected as much as the corneal stroma in keratoconus. SETTING University Eye Clinic, Bern, Switzerland. DESIGN Comparative case-control study. METHODS Eyes with keratoconus (keratoconus group) and eyes of age-, sex-, and axial length-matched controls (control group) were analyzed. Corneal videokeratometry and pachymetry were performed using a Scheimpflug tomographer (Pentacam). For measurements of the peripheral cornea and the anterior sclera, a spectral-domain anterior segment optical coherence tomography device (Spectralis) was used. RESULTS The study group comprised 51 eyes and the control group, 50 eyes. The mean central corneal thickness in the keratoconus group was statistically significantly lower than in the control group (447.8 μm ± 57.8 [SD] versus 550.5 ± 35.5 μm) (P < .0001). No significant difference in the mean anterior scleral thickness was found between the keratoconus group and the control group (479.1 ± 43.7 μm versus 474.2 ± 43.0 μm) (P =.57). CONCLUSION Although corneal thinning was observed in keratoconus patients, the anterior scleral stroma thickness in these patients seemed to be similar to that in healthy control eyes.

Formato

application/pdf

Identificador

http://boris.unibe.ch/73385/1/1-s2.0-S0886335015004216-main.pdf

Schlatter, Bettina; Beck, Marco; Früh Epstein, Beatrice; Tappeiner, Christoph; Zinkernagel, Martin (2015). Evaluation of scleral and corneal thickness in keratoconus patients. Journal of cataract and refractive surgery, 41(5), pp. 1073-1080. Elsevier 10.1016/j.jcrs.2014.08.035 <http://dx.doi.org/10.1016/j.jcrs.2014.08.035>

doi:10.7892/boris.73385

info:doi:10.1016/j.jcrs.2014.08.035

info:pmid:25935338

urn:issn:0886-3350

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/73385/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Schlatter, Bettina; Beck, Marco; Früh Epstein, Beatrice; Tappeiner, Christoph; Zinkernagel, Martin (2015). Evaluation of scleral and corneal thickness in keratoconus patients. Journal of cataract and refractive surgery, 41(5), pp. 1073-1080. Elsevier 10.1016/j.jcrs.2014.08.035 <http://dx.doi.org/10.1016/j.jcrs.2014.08.035>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed