916 resultados para glass plate
Resumo:
Broken glass plate negative. Goal To design a simple protective enclosure for the two pieces of the glass plate negative, that allows the user to visualize the image as a whole. Treatment A sink mat was created by layering museum board and Volera foam, and "sinks" cut to fit the broken pieces along with thumb notches for ease of lifting. A portfolio of e-flute board, buckram, and cotton ties was built up around the sink mat to provide a protective enclosure that is easily stored on edge.
Resumo:
In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.
Resumo:
Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors
Resumo:
The aim of this study was to evaluate the microtensile bond strength (µTBS) of two substrates (enamel and dentin) considering two study factors: type of composite resin [methacrylate-based (Filtek Supreme) or silorane-based (Filtek LS)] and aging time (24 h or 3 months). Twenty human molars were selected and divided into 2 groups (n=10) considering two dental substrates, enamel or dentin. The enamel and dentin of each tooth was divided into two halves separated by a glass plate. Each tooth was restored using both tested composite resins following the manufacturer's instructions. The samples were sectioned, producing 4 sticks for each composite resin. Half of them were tested after 24 h and half after 3 months. µTBS testing was carried out at 0.05 mm/s. Data were analyzed by three-way ANOVA and Tukey's HSD tests at α=0.05. Significant differences between composite resins and substrates were found (p<0.05), but no statistically significant difference was found for aging time and interactions among study factors. The methacrylate-based resin showed higher µTBS than the silorane-based resin. The µTBS for enamel was significantly higher than for dentin, irrespective of the composite resin and storage time. Three months of storage was not sufficient time to cause degradation of the bonding interaction of either of the composite resins to enamel and dentin.
Resumo:
Films of poly (2,5-dicyano-p-phenylene vinylene), DCNPPV, were obtained by electrochemical synthesis over gold thin layer (20 nm) transparent electrode deposited on a glass plate. The DCNPPV films of 4 µm thickness were produced by electropolymerization process of α,α,α',α'-tetrabromo-2-5-dicyano-p-xilene at different applied potentials (-0.15, -0.25, -0.40, -0.60, -0.80, and -1.0 V) using 0.1 mol L-1 of tetraethylammonium bromide in acetonitrile as the supporting electrolyte. The emission decays have three exponential components: a fast component in the picosecond range (200-400 ps), and two other of about one and five nanoseconds at 293 K. The fluorescence quenching process seems to occur by exciton trapping in a low-energy site and quenching by residual bromine monomer attached at the end of the polymer chain. However, the electrochemical synthesis generates entrapped bromide or ion pairs during the growth step of the film which also contributes to the deactivation. The change of the electrolyte from bromide to perchlorate reduces significantly this additional quenching effect by allowing ion exchange of formed bromide with the nonquenching perchloride anion.
Resumo:
A recently developed technique, namely multiple beam interference microscopy, has been applied to investigate the morphology of the parasite Toxoplasma gondii for the first time. The interference pattern obtained from the multiple internal reflection of a T. gondii, sandwiched between a glass plate and a cover plate, was focused on the objective of a conventional microscope. Because of the enhance contrast, several details of sub cellular structure and separating compartments are clearly visible. Details reveal the presence of a nucleus, lipid body, dense granule, rhoptry and amylopectin. The wall thickness of the membrane of the lipid body and the amylopectin is of the order of 0.02 µm and can be clearly distinguished with the help of the present technique. The same parasite has also been examined with the help of atomic force microscopy, and because of its thick membrane, the inner structural details were not observed at all. Sub cellular details of T. gondii observed with the present technique have been reported earlier only by low amplification transmission electron microscopy and not by any optical microscopic technique.
Resumo:
Laser diffraction (LD) and static image analysis (SIA) of rectangular particles [United States Pharmacopeia, USP30-NF25, General Chapter <776>, Optical Miroscopy.] have been systematically studied. To rule out sample dispersion and particle orientation as the root cause of differences in size distribution profiles, we immobilize powder samples on a glass plate by means of a dry disperser. For a defined region of the glass plate, we measure the diffraction pattern as induced by the dispersed particles, and the 2D dimensions of the individual particles using LD and optical microscopy, respectively. We demonstrate a correlation between LD and SIA, with the scattering intensity of the individual particles as the dominant factor. In theory, the scattering intensity is related to the square of the projected area of both spherical and rectangular particles. In traditional LD the size distribution profile is dominated by the maximum projected area of the particles (A). The diffraction diameters of a rectangular particle with length L and breadth B as measured by the LD instrument approximately correspond to spheres of diameter ØL and ØB respectively. Differences in the scattering intensity between spherical and rectangular particles suggest that the contribution made to the overall LD volume probability distribution by each rectangular particle is proportional to A2/L and A2/B. Accordingly, for rectangular particles the scattering intensity weighted diffraction diameter (SIWDD) explains an overestimation of their shortest dimension and an underestimation of their longest dimension. This study analyzes various samples of particles whose length ranges from approximately 10 to 1000 μm. The correlation we demonstrate between LD and SIA can be used to improve validation of LD methods based on SIA data for a variety of pharmaceutical powders all with a different rectangular particle size and shape.
Resumo:
A simple device for glass plate drilling, which is an important step in microfabrication procedures, is described. A reservoir of concentrated hydrofluoric acid with a hole in its bottom is affixed against the glass plate. Leakage is prevented by using a neoprene O-ring. A plastic pipet tip inserted in the reservoir, close to the corrosion region, provides forced convection by pressure variations inside it. A device to make 5 simultaneous holes in a plate is also presented. For a 140 µm thickness alkaline glass lamina and 1/8" O-ring, 5 holes are drilled in 20 min.
Resumo:
The Canadian Niagara Power Company was created in 1892, in large part due to the efforts of William Birch Rankine, a businessman who pioneered the development of hydropower on both the Canadian and American shores of the Niagara River. Numerous delays and problems postponed the construction and operation of the company's powerhouse, which was formally opened on January 2, 1905. Upon opening, the powerhouse boasted the largest generators of their kind in the world, with a capacity of 10,000 electrical horsepower each. The company was acquired by FortisOntario in 2002. In 2009, the company’s water rights expired and the Canadian Niagara Powerhouse building, also known as the Rankine Generating Station, was turned over to the Niagara Parks Commission.
Resumo:
Two-dimensional electronic systems play a crucial role in modern electronics and offer a multitude of opportunities to study the fundamental phenomena at low dimensional physics. A quantum well heterostructure based on polyaniline (P) and iodine doped polyaniline (I) thin films were fabricated using radio frequency plasma polymerization on indium tin oxide coated glass plate. Scanning probe microscopy and scanning electron microscopy studies were employed to study the morphology and roughness of the polymer thin films. Local electronic density of states (LDOS) of the P–I–P heterostructures is probed using scanning tunnelling spectroscopy (STS). A step like LDOS is observed in the P–I–P heterostructure and is attributed to the quantum well confinement of electrons in the polymer heterostructure.
Resumo:
Zusammenfassung (deutsch) Seit den 1980iger Jahren wächst die Bedeutung der sog. Bildschaffenden Methoden für die Bestimmung der Qualität ökologischer Produkte. Zu diesen Methoden gehört die Biokristallisation, Steigbild und Rundfilter-Chromatographie. Die Ergebnisse dieser Methoden sind Bilder, die anhand definierter Kriterien ausgewertet werden. Bei der Biokristallisation sind es mehr oder weniger geordnete Kristallisationen auf einer Glasplatte, bei dem Steigbild zweidimensionale Strukturen auf Chromatographiepapier. In der Vergangenheit wurden die Bilder von Spezialisten ausgewertet, die nach einer längeren Schulung produktspezifische Kriterien entwickelt hatten. Im Gegensatz zur Dünnschicht-Chromatographie, wo der einzelne Stoff von der Matrix separiert wird, ist das Ziel beim Steigbild, Strukturen der möglichst ganzen Probe zu erzeugen. Die Methode wurde von Kolisko in den 1929iger Jahren entwickelt, wobei eine Kombination aus Chromatographieprozess und Metallkomplexreaktionen genutzt wurde. Die Firma WALA entwickelte die Methode für die Kontrolle ihrer Produkte und setze Silbernitrat und Eisensulfat ein. Bisher wurde die Methode qualitativ beschreibend ausgewertet, wobei einzelne Bildelemente und deren Interaktion beschrieben wurden. Deshalb musste für die vorliegende Arbeit Auswertungsmethoden entwickelt werden, mit denen auch eine statistische Bearbeitung der Ergebnisse möglich ist (nominale Unterscheidung von proben anhand der Bilder). Die Methode wurde bisher in einer Reihe von Studien eingesetzt (u.a. die Unterscheidung von Produktionsweisen). Obwohl die Bilder nur qualitativ ausgewertet wurden, konnten geschulte Prüfpersonen Proben aus verschiedenen Anbausystemen anhand der Bilder trennen. Die Ergebnisse wurden aber nicht so dokumentiert, dass sie den Erfordernissen internationaler Standardnormen für Laboratorien genügten. Deshalb mussten für diese Arbeit zunächst die Prozeduren dokumentiert und eine systematische Untersuchung zu den Einflussgrößen durchgeführt werden. Dazu wurde die visuelle Bildauswertung entwickelt und standardisiert. Die visuelle Bildauswertung basiert auf morphologischen Kriterien der Bilder von den untersuchten Weizen- und Möhrenproben. Ein Panel aus geschulten Personen entwickelte dann die Kriterien und legte sie anhand von Referenzbildern fest. Die Bilder der vorliegenden Arbeit wurden mit der einfach beschreibenden Prüfung ausgewertet, wie sie aus der sensorischen Prüfung von Lebensmitteln übernommen werden konnte. Mit geschulten und ungeschulten Prüfpersonen wurden Weizenproben und verschiedene Möhrensäfte mit der sog. Dreiecksprüfung ausgewertet (von ISO 4120). Alle Laborprozeduren wurden dokumentiert. Mit der Anwendung dieser Prozeduren wurden Vergleichsversuche mit Laboren in Dänemark und Holland (BRAD, LBI) durchgeführt. Die Ergebnisse waren sowohl für Weizen- als auch für Möhrenproben vergleichbar, wobei alle drei Labore zwischen jeweils zwei Proben unterscheiden konnten. Die systematische Untersuchung zu den Einflussgrößen zeigte, dass das Unterscheidungsvermögen der Methode vor allem von den klimatischen Bedingungen während der Steigphasen beeinflusst wird. Auch die Präkonditionierung der Papiere hat einen großen Einfluss, während die Wasserqualität (ultra-filtriert, de-ionisiert, destilliert) eine untergeordnete Bedeutung hat. Für Weizen- und Möhrenproben wurde sowohl die Wiederholbarkeit als auch die Reproduzierbarkeit getestet. Die Unterschiede in den Bildern der verschiedenen Proben waren dabei immer größer als die Variation durch Proben- und Bildwiederholung und das Labor. Die so charakterisierte Methode wurde auf kodierte Proben von definierten Feldversuchen und auf Marktproben (Paarvergleich von Anbausystemen ökologisch und konventionell) angewandt, wobei als Ergebnis mehr als 90% der Proben mit der einfach beschreibenden Prüfung anhand der Bilder unterschieden werden konnten. Die Auswertung mit der Dreiecksprüfung zeigte, dass sowohl Sorten und Verarbeitungsschritte (Saft) als auch Anbauweisen signifikant getrennt wurden. Darüber hinaus wurde die Methode auch erfolgreich auf Apfelproben angewandt. Weitere Untersuchungen müssen zeigen, ob sich das Potential der Methode, verschiedene Fragen wie die Authentizitätsprüfung von Lebensmitteln verifizieren lassen.
Resumo:
OBJETIVO: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. METODOLOGIA: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. RESULTADOS: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. CONCLUSÃO: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).
Resumo:
Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.
Resumo:
The flat-panel-display's (FPD) market and demand for highly efficient and colored luminescent films have been growing quickly. In this work, thin films were obtained from Pechini's solution by dip-coating. The green films were thermally treated at 873 K in order to get ZnO:Eu 1 at% thin film. A Schott(R) glass plate hydrothermally treated was used as substrate. The films have a mosaic shaped feature that was observed by optical microscopy. That feature is a result of substrate thermal treatment. The film deposition decreases the substrate transmittance in the visible range. When the F-7(0) -->L-5(6) (392nm) Eu3+ transition is excited, it is possible to detect emission from D-5(0) --> F-7(J) (J = 1, 2, 3 and 4) transitions. The D-5(0) --> F-7(2) transition is also observed by using ZnO excitation wavelengths indicating energy transfer from ZnO to Eu3+ ion. (C) 2003 Elsevier B.V. (USA). All rights reserved.