Physicochemical properties of endodontic sealers of different bases


Autoria(s): Marin-Bauza, Gabriela Alexandra; Correa Silva-Sousa, Yara Teresinha; da Cunha, Suely Aparecida; Abi Rached-Junior, Fuad Jacob; Bonetti-Filho, Idomeo; Damiao Sousa-Neto, Manoel; Saraiva Miranda, Carlos Eduardo
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/07/2012

Resumo

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Formato

455-461

Identificador

http://dx.doi.org/10.1590/S1678-77572012000400011

Journal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 20, n. 4, p. 455-461, 2012.

1678-7757

http://hdl.handle.net/11449/16770

S1678-77572012000400011

WOS:000309419000011

S1678-77572012000400011.pdf

Idioma(s)

eng

Publicador

Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru

Relação

Journal of Applied Oral Science

Direitos

openAccess

Palavras-Chave #Endodontics #Root canal obturation #Root canal filling materials
Tipo

info:eu-repo/semantics/article