998 resultados para four-port
Resumo:
Computer aided design of Monolithic Microwave Integrated Circuits (MMICs) depends critically on active device models that are accurate, computationally efficient, and easily extracted from measurements or device simulators. Empirical models of active electron devices, which are based on actual device measurements, do not provide a detailed description of the electron device physics. However they are numerically efficient and quite accurate. These characteristics make them very suitable for MMIC design in the framework of commercially available CAD tools. In the empirical model formulation it is very important to separate linear memory effects (parasitic effects) from the nonlinear effects (intrinsic effects). Thus an empirical active device model is generally described by an extrinsic linear part which accounts for the parasitic passive structures connecting the nonlinear intrinsic electron device to the external world. An important task circuit designers deal with is evaluating the ultimate potential of a device for specific applications. In fact once the technology has been selected, the designer would choose the best device for the particular application and the best device for the different blocks composing the overall MMIC. Thus in order to accurately reproducing the behaviour of different-in-size devices, good scalability properties of the model are necessarily required. Another important aspect of empirical modelling of electron devices is the mathematical (or equivalent circuit) description of the nonlinearities inherently associated with the intrinsic device. Once the model has been defined, the proper measurements for the characterization of the device are performed in order to identify the model. Hence, the correct measurement of the device nonlinear characteristics (in the device characterization phase) and their reconstruction (in the identification or even simulation phase) are two of the more important aspects of empirical modelling. This thesis presents an original contribution to nonlinear electron device empirical modelling treating the issues of model scalability and reconstruction of the device nonlinear characteristics. The scalability of an empirical model strictly depends on the scalability of the linear extrinsic parasitic network, which should possibly maintain the link between technological process parameters and the corresponding device electrical response. Since lumped parasitic networks, together with simple linear scaling rules, cannot provide accurate scalable models, either complicate technology-dependent scaling rules or computationally inefficient distributed models are available in literature. This thesis shows how the above mentioned problems can be avoided through the use of commercially available electromagnetic (EM) simulators. They enable the actual device geometry and material stratification, as well as losses in the dielectrics and electrodes, to be taken into account for any given device structure and size, providing an accurate description of the parasitic effects which occur in the device passive structure. It is shown how the electron device behaviour can be described as an equivalent two-port intrinsic nonlinear block connected to a linear distributed four-port passive parasitic network, which is identified by means of the EM simulation of the device layout, allowing for better frequency extrapolation and scalability properties than conventional empirical models. Concerning the issue of the reconstruction of the nonlinear electron device characteristics, a data approximation algorithm has been developed for the exploitation in the framework of empirical table look-up nonlinear models. Such an approach is based on the strong analogy between timedomain signal reconstruction from a set of samples and the continuous approximation of device nonlinear characteristics on the basis of a finite grid of measurements. According to this criterion, nonlinear empirical device modelling can be carried out by using, in the sampled voltage domain, typical methods of the time-domain sampling theory.
Resumo:
Las fuentes de alimentación de modo conmutado (SMPS en sus siglas en inglés) se utilizan ampliamente en una gran variedad de aplicaciones. La tarea más difícil para los diseñadores de SMPS consiste en lograr simultáneamente la operación del convertidor con alto rendimiento y alta densidad de energía. El tamaño y el peso de un convertidor de potencia está dominado por los componentes pasivos, ya que estos elementos son normalmente más grandes y más pesados que otros elementos en el circuito. Para una potencia de salida dada, la cantidad de energía almacenada en el convertidor que ha de ser entregada a la carga en cada ciclo de conmutación, es inversamente proporcional a la frecuencia de conmutación del convertidor. Por lo tanto, el aumento de la frecuencia de conmutación se considera un medio para lograr soluciones más compactas con los niveles de densidad de potencia más altos. La importancia de investigar en el rango de alta frecuencia de conmutación radica en todos los beneficios que se pueden lograr: además de la reducción en el tamaño de los componentes pasivos, el aumento de la frecuencia de conmutación puede mejorar significativamente prestaciones dinámicas de convertidores de potencia. Almacenamiento de energía pequeña y el período de conmutación corto conducen a una respuesta transitoria del convertidor más rápida en presencia de las variaciones de la tensión de entrada o de la carga. Las limitaciones más importantes del incremento de la frecuencia de conmutación se relacionan con mayores pérdidas del núcleo magnético convencional, así como las pérdidas de los devanados debido a los efectos pelicular y proximidad. También, un problema potencial es el aumento de los efectos de los elementos parásitos de los componentes magnéticos - inductancia de dispersión y la capacidad entre los devanados - que causan pérdidas adicionales debido a las corrientes no deseadas. Otro factor limitante supone el incremento de las pérdidas de conmutación y el aumento de la influencia de los elementos parásitos (pistas de circuitos impresos, interconexiones y empaquetado) en el comportamiento del circuito. El uso de topologías resonantes puede abordar estos problemas mediante el uso de las técnicas de conmutaciones suaves para reducir las pérdidas de conmutación incorporando los parásitos en los elementos del circuito. Sin embargo, las mejoras de rendimiento se reducen significativamente debido a las corrientes circulantes cuando el convertidor opera fuera de las condiciones de funcionamiento nominales. A medida que la tensión de entrada o la carga cambian las corrientes circulantes incrementan en comparación con aquellos en condiciones de funcionamiento nominales. Se pueden obtener muchos beneficios potenciales de la operación de convertidores resonantes a más alta frecuencia si se emplean en aplicaciones con condiciones de tensión de entrada favorables como las que se encuentran en las arquitecturas de potencia distribuidas. La regulación de la carga y en particular la regulación de la tensión de entrada reducen tanto la densidad de potencia del convertidor como el rendimiento. Debido a la relativamente constante tensión de bus que se encuentra en arquitecturas de potencia distribuidas los convertidores resonantes son adecuados para el uso en convertidores de tipo bus (transformadores cc/cc de estado sólido). En el mercado ya están disponibles productos comerciales de transformadores cc/cc de dos puertos que tienen muy alta densidad de potencia y alto rendimiento se basan en convertidor resonante serie que opera justo en la frecuencia de resonancia y en el orden de los megahercios. Sin embargo, las mejoras futuras en el rendimiento de las arquitecturas de potencia se esperan que vengan del uso de dos o más buses de distribución de baja tensión en vez de una sola. Teniendo eso en cuenta, el objetivo principal de esta tesis es aplicar el concepto del convertidor resonante serie que funciona en su punto óptimo en un nuevo transformador cc/cc bidireccional de puertos múltiples para atender las necesidades futuras de las arquitecturas de potencia. El nuevo transformador cc/cc bidireccional de puertos múltiples se basa en la topología de convertidor resonante serie y reduce a sólo uno el número de componentes magnéticos. Conmutaciones suaves de los interruptores hacen que sea posible la operación en las altas frecuencias de conmutación para alcanzar altas densidades de potencia. Los problemas posibles con respecto a inductancias parásitas se eliminan, ya que se absorben en los Resumen elementos del circuito. El convertidor se caracteriza con una muy buena regulación de la carga propia y cruzada debido a sus pequeñas impedancias de salida intrínsecas. El transformador cc/cc de puertos múltiples opera a una frecuencia de conmutación fija y sin regulación de la tensión de entrada. En esta tesis se analiza de forma teórica y en profundidad el funcionamiento y el diseño de la topología y del transformador, modelándolos en detalle para poder optimizar su diseño. Los resultados experimentales obtenidos se corresponden con gran exactitud a aquellos proporcionados por los modelos. El efecto de los elementos parásitos son críticos y afectan a diferentes aspectos del convertidor, regulación de la tensión de salida, pérdidas de conducción, regulación cruzada, etc. También se obtienen los criterios de diseño para seleccionar los valores de los condensadores de resonancia para lograr diferentes objetivos de diseño, tales como pérdidas de conducción mínimas, la eliminación de la regulación cruzada o conmutación en apagado con corriente cero en plena carga de todos los puentes secundarios. Las conmutaciones en encendido con tensión cero en todos los interruptores se consiguen ajustando el entrehierro para obtener una inductancia magnetizante finita en el transformador. Se propone, además, un cambio en los señales de disparo para conseguir que la operación con conmutaciones en apagado con corriente cero de todos los puentes secundarios sea independiente de la variación de la carga y de las tolerancias de los condensadores resonantes. La viabilidad de la topología propuesta se verifica a través una extensa tarea de simulación y el trabajo experimental. La optimización del diseño del transformador de alta frecuencia también se aborda en este trabajo, ya que es el componente más voluminoso en el convertidor. El impacto de de la duración del tiempo muerto y el tamaño del entrehierro en el rendimiento del convertidor se analizan en un ejemplo de diseño de transformador cc/cc de tres puertos y cientos de vatios de potencia. En la parte final de esta investigación se considera la implementación y el análisis de las prestaciones de un transformador cc/cc de cuatro puertos para una aplicación de muy baja tensión y de decenas de vatios de potencia, y sin requisitos de aislamiento. Abstract Recently, switch mode power supplies (SMPS) have been used in a great variety of applications. The most challenging issue for designers of SMPS is to achieve simultaneously high efficiency operation at high power density. The size and weight of a power converter is dominated by the passive components since these elements are normally larger and heavier than other elements in the circuit. If the output power is constant, the stored amount of energy in the converter which is to be delivered to the load in each switching cycle is inversely proportional to the converter’s switching frequency. Therefore, increasing the switching frequency is considered a mean to achieve more compact solutions at higher power density levels. The importance of investigation in high switching frequency range comes from all the benefits that can be achieved. Besides the reduction in size of passive components, increasing switching frequency can significantly improve dynamic performances of power converters. Small energy storage and short switching period lead to faster transient response of the converter against the input voltage and load variations. The most important limitations for pushing up the switching frequency are related to increased conventional magnetic core loss as well as the winding loss due to the skin and proximity effect. A potential problem is also increased magnetic parasitics – leakage inductance and capacitance between the windings – that cause additional loss due to unwanted currents. Higher switching loss and the increased influence of printed circuit boards, interconnections and packaging on circuit behavior is another limiting factor. Resonant power conversion can address these problems by using soft switching techniques to reduce switching loss incorporating the parasitics into the circuit elements. However the performance gains are significantly reduced due to the circulating currents when the converter operates out of the nominal operating conditions. As the input voltage or the load change the circulating currents become higher comparing to those ones at nominal operating conditions. Multiple Input-Output Many potential gains from operating resonant converters at higher switching frequency can be obtained if they are employed in applications with favorable input voltage conditions such as those found in distributed power architectures. Load and particularly input voltage regulation reduce a converter’s power density and efficiency. Due to a relatively constant bus voltage in distributed power architectures the resonant converters are suitable for bus voltage conversion (dc/dc or solid state transformation). Unregulated two port dc/dc transformer products achieving very high power density and efficiency figures are based on series resonant converter operating just at the resonant frequency and operating in the megahertz range are already available in the market. However, further efficiency improvements of power architectures are expected to come from using two or more separate low voltage distribution buses instead of a single one. The principal objective of this dissertation is to implement the concept of the series resonant converter operating at its optimum point into a novel bidirectional multiple port dc/dc transformer to address the future needs of power architectures. The new multiple port dc/dc transformer is based on a series resonant converter topology and reduces to only one the number of magnetic components. Soft switching commutations make possible high switching frequencies to be adopted and high power densities to be achieved. Possible problems regarding stray inductances are eliminated since they are absorbed into the circuit elements. The converter features very good inherent load and cross regulation due to the small output impedances. The proposed multiple port dc/dc transformer operates at fixed switching frequency without line regulation. Extensive theoretical analysis of the topology and modeling in details are provided in order to compare with the experimental results. The relationships that show how the output voltage regulation and conduction losses are affected by the circuit parasitics are derived. The methods to select the resonant capacitor values to achieve different design goals such as minimum conduction losses, elimination of cross regulation or ZCS operation at full load of all the secondary side bridges are discussed. ZVS turn-on of all the switches is achieved by relying on the finite magnetizing inductance of the Abstract transformer. A change of the driving pattern is proposed to achieve ZCS operation of all the secondary side bridges independent on load variations or resonant capacitor tolerances. The feasibility of the proposed topology is verified through extensive simulation and experimental work. The optimization of the high frequency transformer design is also addressed in this work since it is the most bulky component in the converter. The impact of dead time interval and the gap size on the overall converter efficiency is analyzed on the design example of the three port dc/dc transformer of several hundreds of watts of the output power for high voltage applications. The final part of this research considers the implementation and performance analysis of the four port dc/dc transformer in a low voltage application of tens of watts of the output power and without isolation requirements.
Resumo:
INTRODUCTION: We describe our center's initial experience with alcohol septal ablation (ASA) for the treatment of obstructive hypertrophic cardiomyopathy. The procedure, its indications, results and clinical outcomes will be addressed, as will its current position compared to surgical myectomy. OBJECTIVE: To assess the results of ASA in all patients treated in the first four years of activity at our center. METHODS: We retrospectively studied all consecutive and unselected patients treated by ASA between January 2009 and February 2013. RESULTS: In the first four years of experience 40 patients were treated in our center. In three patients (7.5%) the intervention was repeated. Procedural success was 84%. Minor complications occurred in 7.5%. Two patients received a permanent pacemaker for atrioventricular block (6% of those without previous pacemaker). The major complication rate was 5%. There were no in-hospital deaths; during clinical follow-up (22 ± 14 months) cardiovascular mortality was 2.5% and overall mortality was 5%. DISCUSSION AND CONCLUSION: The results presented reflect the initial experience of our center with ASA. The success rate was high and in line with published results, but with room to improve with better patient selection. ASA was shown to be safe, with a low complication rate and no procedure-related mortality. Our experience confirms ASA as a percutaneous alternative to myectomy for the treatment of symptomatic patients with obstructive hypertrophic cardiomyopathy refractory to medical treatment.
Resumo:
Roraima is the northernmost state of Brazil, bordering both Venezuela and Guyana. Appropriate climate and vector conditions for dengue transmission together with its proximity to countries where all four dengue serotypes circulate make this state, particularly the capital Boa Vista, strategically important for dengue surveillance in Brazil. Nonetheless, few studies have addressed the population dynamics of Aedes aegypti in Boa Vista. In this study, we report temporal and spatial variations in Ae. aegypti population density using ovitraps in two highly populated neighbourhoods; Centro and Tancredo Neves. In three out of six surveys, Ae. aegypti was present in more than 80% of the sites visited. High presence levels of this mosquito suggest ubiquitous human exposure to the vector, at least during part of the year. The highest infestation rates occurred during the peak of the rainy seasons, but a large presence was also observed during the early dry season (although with more variation among years). Spatial distribution of positive houses changed from a sparse and local pattern to a very dense pattern during the dry-wet season transition. These results suggest that the risk of dengue transmission and the potential for the new serotype invasions are high for most of the year.
Resumo:
RESUME BUT Cette étude a été menée sur le suivi de patients traités pour un glioblastome nouvellement diagnostiqué. Son objectif a été de déterminer l'impact des séquences de perfusion et de diffusion en imagerie par résonance magnétique (IRM). Un intérêt particulier a été porté au potentiel de ces nouvelles techniques d'imagerie dans l'anticipation de la progression de la maladie. En effet, l'intervalle de temps libre de progression est une mesure alternative de pronostic fréquemment utilisée. MATERIEL ET METHODE L'étude a porté sur 41 patients participant à un essai clinique de phase II de traitement par temozolomide. Leur suivi radiologique a comporté un examen IRM dans les 21 à 28 jours après radiochimiothérapie et tous les 2 mois par la suite. L'évaluation des images s'est faite sur la base de l'évaluation de l'effet de masse ainsi que de la mesure de la taille de la lésion sur les images suivantes : T1 avec produit de contraste, T2, diffusion, perfusion. Afin de déterminer la date de progression de la maladie, les critères classiques de variation de taille adjoints aux critères cliniques habituels ont été utilisés. RESULAT 311 examens IRM ont été revus. Au moment de la progression (32 patients), une régression multivariée selon Cox a permis de déterminer deux paramètres de survie : diamètre maximal en T1 (p>0.02) et variation de taille en T2 (p<0.05). L'impact de la perfusion et de la diffusion n'a pas été démontré de manière statistiquement significative. CONCLUSION Les techniques de perfusion et de diffusion ne peuvent pas être utilisées pour anticiper la progression tumorale. Alors que la prise de décision au niveau thérapeutique est critique au moment de la progression de la maladie, l'IRM classique en T1 et en T2 reste la méthode d'imagerie de choix. De manière plus spécifique, une prise de contraste en T1 supérieure à 3 cm dans son plus grand diamètre associée à un hypersignal T2 en augmentation forment un marqueur de mauvais pronostic.
Resumo:
INTRODUCTION : L’articulation temporo-mandibulaire (ATM) est un système articulaire excessivement complexe. L'étiologie des désordres temporo-mandibulaires (DTM) est encore incertaine et le lien de cause à effet des traitements orthodontiques en tant que facteur de risque est une question qui a longuement été discutée. Cette étude clinique prospective vise à évaluer les effets à long terme du port continu de coquilles correctrices Invisalign® sur l’ATM et les muscles du complexe facial. MATÉRIELS ET MÉTHODES : L'étude incluait 43 adolescents et adultes âgés entre 13 et 51 ans (25 femmes et 18 hommes). Deux d'entre eux ont été exclus en raison de mauvaise coopération causant l’arrêt du traitement orthodontique. Les effets dans le temps des coquilles sur l'ATM et les muscles du complexe facial ont été évalués en utilisant l’examen du Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). Le nombre de contractions musculaires durant le sommeil a été mesuré objectivement par enregistrements électromyographiques (EMG) et la fréquence de grincement et de serrement des dents à l’éveil a été rapportée subjectivement par les patients à l’aide de questionnaires. Des mesures répétées ont été effectuées aux temps suivants: avant le début du traitement pour les données contrôles (T1), deux semaines (T2), et six mois (T3) après le début du traitement. Les données numériques ont été analysées par l’analyse de variance (ANOVA) en mesures répétées et la méthode de Brunner-Langer, alors que les données nominales ont été évaluées par le test de Cochran-Mantel-Haenszel. Les résultats ont été considérés significatifs si p < 0.05. RÉSULTATS ET DISCUSSION : Le nombre de contractions musculaires par heure (index) durant le sommeil et leur durée moyenne n’ont pas été statistiquement différents entre les trois nuits d’enregistrement EMG (Brunner Langer, p > 0.005). Cependant, 67 % des participants ont rapporté avoir eu du grincement ou du serrement des dents la nuit au T2 et 64 % au T3 comparativement à 39 % au T1, ce qui était une augmentation significative (Cochran-Mantel-Haenszel, p = 0.0112). Quarante-quatre pour cent des patients ont signalé du grincement ou du serrement des dents pendant le jour au T1, tandis qu'un pourcentage nettement plus élevé de 66 % en a rapporté au T2 et 61 % au T3 (Cochran-Mantel-Haenszel, p = 0.0294). Au T1, 12 % des sujets ont indiqué qu'ils se sont réveillés avec une douleur musculaire, comparativement à 29 % au T2, ce qui était une augmentation significative (Cochran-Mantel-Haenszel, p = 0.0347). Au T2, il y avait une réduction significative des mouvements maximaux de la mandibule dans toutes les directions (ANOVA en mesures répétées, p < 0,05). De plus, il y a eu une augmentation significative du nombre de sites douloureux et de l'intensité de la douleur à la palpation de l'ATM et des muscles faciaux avec l'évaluation du RDC/TMD au T2 en comparaison aux T1 et T3 (Brunner Langer, p < 0,05). CONCLUSION : La présente étude n’a révélé aucun effet des coquilles sur l’activité oro-faciale durant le sommeil au fil du temps mesurée objectivement à l’aide des enregistrements EMG, mais une augmentation significative de la fréquence du grincement et du serrement des dents rapportée subjectivement par les patients au moyen des questionnaires aux T2 et T3. Au T2, il y avait une augmentation significative des symptômes de l'ATM et des muscles du complexe oro-facial, mais ces symptômes sont retournés au niveau initial avec le temps.
Resumo:
The ninth Inter-American Port and Harbour Conference of the Organization of American States (OAS) was held in Asuncion, Paraguay, from 23 to 27 September 1996, and was declared open by His Excellency Mr. Juan Carlos Wasmosy Monti, President of the Republic of Paraguay. Representatives from 24 countries of the Americas, four European countries and one Middle Eastern country participated. The Conference was also attended by observers from six regional or international organizations and by special guests from business and academic circles.
Resumo:
This is the name of the course presented by ECLAC's Transport Unit in range of countries in four continents for ministerial and port authorities, transport companies, exporters, importers and trade unions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.
Resumo:
La stratégie actuelle de contrôle de la qualité de l’anode est inadéquate pour détecter les anodes défectueuses avant qu’elles ne soient installées dans les cuves d’électrolyse. Des travaux antérieurs ont porté sur la modélisation du procédé de fabrication des anodes afin de prédire leurs propriétés directement après la cuisson en utilisant des méthodes statistiques multivariées. La stratégie de carottage des anodes utilisée à l’usine partenaire fait en sorte que ce modèle ne peut être utilisé que pour prédire les propriétés des anodes cuites aux positions les plus chaudes et les plus froides du four à cuire. Le travail actuel propose une stratégie pour considérer l’histoire thermique des anodes cuites à n’importe quelle position et permettre de prédire leurs propriétés. Il est montré qu’en combinant des variables binaires pour définir l’alvéole et la position de cuisson avec les données routinières mesurées sur le four à cuire, les profils de température des anodes cuites à différentes positions peuvent être prédits. Également, ces données ont été incluses dans le modèle pour la prédiction des propriétés des anodes. Les résultats de prédiction ont été validés en effectuant du carottage supplémentaire et les performances du modèle sont concluantes pour la densité apparente et réelle, la force de compression, la réactivité à l’air et le Lc et ce peu importe la position de cuisson.
Resumo:
At the national level, with a fixed amount of resources available for public investment in the restoration of biodiversity, it is difficult to prioritize alternative restoration projects. One way to do this is to assess the level of ecosystem services delivered by these projects and to compare them with their costs. The challenge is to derive a common unit of measurement for ecosystem services in order to compare projects which are carried out in different institutional contexts having different goals (application of environmental laws, management of natural reserves, etc.). This paper assesses the use of habitat equivalency analysis (HEA) as a tool to evaluate ecosystem services provided by restoration projects developed in different institutional contexts. This tool was initially developed to quantify the level of ecosystem services required to compensate for non-market impacts coming from accidental pollution in the US. In this paper, HEA is used to assess the cost effectiveness of several restoration projects in relation to different environmental policies, using case studies based in France. Four case studies were used: the creation of a market for wetlands, public acceptance of a port development project, the rehabilitation of marshes to mitigate nitrate loading to the sea, and the restoration of streams in a protected area. Our main conclusion is that HEA can provide a simple tool to clarify the objectives of restoration projects, to compare the cost and effectiveness of these projects, and to carry out trade-offs, without requiring significant amounts of human or technical resources.
Resumo:
Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.
Resumo:
The aim of the present study was to compare four methods of fixation in mandibular body fractures. Mechanical and photoelastic tests were performed using polyurethane and photoelastic resin mandibles, respectively. The study groups contained the following: (I), two miniplates of 2.0 mm; (II) one 2.0 mm plate and an Erich arch bar; (III) one 2.4 mm plate and an Erich arch bar, and (IV) one 2.0 mm plate and one 2.4 mm plate. The differences between the mean values were analyzed using Tukey's test, the Mann-Whitney test and the Bonferroni correction. Group II recorded the lowest resistance, followed by groups I, IV and III. The photoelastic test confirmed the increase of tension in group II. The 2.4 mm system board in linear mandibular body fractures provided more resistance and the use of only one 2.0 mm plate in the central area of the mandible created higher tension.
Resumo:
A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.